background image

11 

 

This box must be checked at all times. 

 

Checking this option will tell the unit to copy all received data from the GPS 
module's serial port to the serial port on the back of the Time Server. The copied 
strings are the standard NMEA GPS data strings. 

3.2.14 Serial TTL Level Outputs Checkbox 

 

This box must be checked at all times. 

 

Checking this option will enable the TTL level outputs of the serial port. These are found on Pins 
7, 8, and 1. To receive the actual NMEA strings, the “Echo GPS Strings Checkbox” must be 
checked. Pin 7 is the data from the GPS module, Pin 8 is data that will be sent to the GPS 
module through the RS-232C port echo'd at TTL level. The data pins are duplicates of the RS-
232C data found on Pins 2 and 3, but are provided before conversion to RS-232C levels. Pin 1 is 
the 1 PPS output. The 1 PPS output is a very narrow signal on the order of 1 uS in width, active 
high. 

3.2.15  Debug Output Checkbox 

 

The debug output checkbox will tell the unit to output debug and operational information to the 
serial port. 

3.2.16 Unit Name 

 

This can be any alpha numeric name up to 20 characters long. 

3.2.17 Password 

 

The password field displays the current password. To change it, enter a new password, push Save 
and then Reboot for it to take effect. Time Server passwords are limited to12 characters.  
 

The default password is “tmachine” 

3.3 Display Configuration 

 
The time server front panel buttons are used to control and configure only the display and not the 
time server engine.  Display configuration is accomplished by editing parameters using a simple 
menu system.  Only four buttons are used to navigate the menu.  The Mode button enters the 
Menu.  The Up and Down buttons move up and down through the menu items, and are used to 
change parameter values.  The TC button is used to save any changes and exit the menu system. 
 

Summary of Contents for NTP100B

Page 1: ...1 BRG NTP100B Time Server Stratum 1 GPS Synchronized Time Server USER MANUAL BRG Precision Products 600 N River Street Derby Kansas 67037 http www brgproducts com sales brgproducts com 7 30 2020 ...

Page 2: ...3 2 6 IPv6 Link Local 9 3 2 7 IPv6 Temporary 10 3 2 8 Mask HTTP access on Subnet 10 3 2 9 Mask NTP access on Subnet 10 3 2 10 Netmask 10 3 2 11 Gateway 10 3 2 12 MAC 10 3 2 13 Echo GPS Strings Checkbox 10 3 2 14 Serial TTL Level Outputs Checkbox 11 3 2 15 Debug Output Checkbox 11 3 2 16 Unit Name 11 3 2 17 Password 11 3 3 Display Configuration 11 4 Troubleshooting 14 4 1 GPS Lock 14 4 2 Finding th...

Page 3: ...3 6 Warranty Agreement 17 7 Payments and Returns 20 ...

Page 4: ...tup within the control box Set parameters to match your network and the system will start to send out time packets to any device on the system that asks for an update from it Multiple servers may be setup to provide redundancy and more capacity When paired with our digital Power over Ethernet PoE clocks synchronized time is assured no matter the state of your network or the state of the internet t...

Page 5: ...lt DC power supply is supplied with the unit Connect one end to a standard United States 110 120 Volt outlet and the barrel connector to the rear of the Time Server The time server will begin trying to find the GPS satellites On power up synchronization to the GPS satellites will take several minutes No battery backup of position is provided to allow for a warm start so the Time Server is always s...

Page 6: ... indicator will display when the time server is locked and sync d to the GPS time signal If the GPS signal is lost the S will turn off 3 Configuration 3 1 Web Page Default password is tmachine 3 2 Default IP address is 192 168 1 15 All Time Server parameters are accessed on the configuration web page The page can be accessed by pointing any web browser at the IP address of the Time Server The init...

Page 7: ...7 Illustration 1 Password Page Default password is tmachine ...

Page 8: ...y default the network parameters are setup to static address 192 168 1 15 The Time Server is able to use DHCP but the rest of the network will need to be able to automatically adjust to its IP address should it change This would involve setup with DHCP and DNS systems Usually ...

Page 9: ...this value will drift based on the characteristics of the HW clock in the browser hardware Refreshing the page will update the time 3 2 3 Use DHCP Checking this option will tell the Time Server to ignore the other IP address settings and request an IP address from the network s DHCP server at startup 3 2 4 IPv4 Address If the DHCP option is not being used then the IP address of the unit set to by ...

Page 10: ...subnet as the time server is configured on This is a security feature to limit the access to the configuration of the device only to the local subnet 3 2 9 Mask NTP access on Subnet This checkbox will enable NTP access only on the time server s configured subnet This allows the time server to ignore requests for time from all devices that are not on the same subnet and provides a measure of securi...

Page 11: ... 1 PPS output is a very narrow signal on the order of 1 uS in width active high 3 2 15 Debug Output Checkbox The debug output checkbox will tell the unit to output debug and operational information to the serial port 3 2 16 Unit Name This can be any alpha numeric name up to 20 characters long 3 2 17 Password The password field displays the current password To change it enter a new password push Sa...

Page 12: ...TC button also exits the menu system The menu will timeout and return to normal operation after 60 seconds in inactivity A special operation menu is available for restoration and diagnostic purposes Pressing and holding the mode button will cause either four one s or four two to be displayed Four one s means no configuration has been stored in secondary memory Four two s means a previous configura...

Page 13: ...e advance 3 30 minute advance during daylight savings time only 4 60 minute advance during daylight savings time only 5 45 minute advance This is used in areas that have a 30 to 60 minute advance over the area time zone For example Mumbai India s time zone offset is 5 30 To configure the time zone first set the respective zone to 5 hours using Mode 21 Then set the same respective zone in Mode 33 t...

Page 14: ...its original location and see if lock is lost This will help determine where lock can be received and where it cannot If no lock is achieved outdoors then something is either wrong with the cabling or the Time Server itself Contact support 4 2 Finding the IP Address If the IP address of the Time Server is forgotten there are a few ways to go about finding its IP address The first is to use a seria...

Page 15: ...r over 300 000 devices updating every 15 minutes on the network Active GPS outdoor antenna and 125 of antenna cable included Compliant with FCC Part 15 class B for radiated emissions and is a lead free product Power Requirements less than 4 Watts continuous at 5 volts DC Environmental Requirements Commercial temperature range 0 70C 95 humidity non condensing Altitude 304m to 18 000m Networking Sta...

Page 16: ...me antenna with swivel mount Size 3 5 89 mm diameter x 8 203 mm high Amplifier LNA 20dB Noise 1 5dB VSWR 2 0 Voltage 2 7 6 0V Cable RG58 BNC male Environmental 40 to 85C Waterproof to IPx6 Specifications are subject to change without notice ...

Page 17: ...uous United States and Canada Alaska and Hawaii return shipments to the Customer are via non expedited air freight 4 What Is Not Covered This Agreement does not cover costs related to the removal installation or field troubleshooting of the Product under the terms of the Agreement if and not limited to a the Product has been misused neglected improperly installed physically damaged or altered eith...

Page 18: ...mits Claims are limited to repair or replacement or if in BRG Precision Products Inc s discretion that is not possible to reimbursement up to the purchase price paid for the Product In no event will BRG Precision Products Inc s liability under this Agreement exceed the purchase price paid for the Product 7 Cancellation You may cancel this Agreement by providing to BRG Precision Products Inc writte...

Page 19: ...ereby 14 Entire Agreement This Agreement constitutes the entire contract between the parties concerning the subject matter of this Agreement and supersedes all marketing brochures and other expectations understandings communications representations and agreements whether verbal or written between the parties THIS AGREEMENT GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VA...

Page 20: ... be voided otherwise the full invoice amount for the replacement product is due This service is only available in conjunction with warranty repairs This replacement service may be purchased for 10 of the products purchase price at the time of the initial purchase The replacement service may also be purchased after the initial product purchase and before the standard warranty expires for 15 of the ...

Page 21: ...may be suspended limiting functionality of the equipment if payment is not received within 90 days Pricing BRG Precision Products reserves the right to change prices without prior notification Prices do not include taxes and BRG reserves the right to arrange for insurance on all orders The courts of Sedgwick County Kansas will have exclusive jurisdiction and venue over any disputes arising from an...

Page 22: ...22 ...

Reviews: