background image

Installing the M10 

 

The M10 can control from one to 8 M7s.  Included your M10 kit is one 10 meter serial cable, for 
connecting the M10 to the first M7 and one serial terminator for the last unit.  This kit is for connection one 
M7 to the M10. 
 

Upgrading the M7s 

If you are adding the M10 to your current setup, you may need to upgrade your M7. If your M7 serial # is 
#0885 or lower, then you will need to upgrade the M7.  Units with serial # 886 and onwards will support 
the M10 with no need to upgrade.  See the Software Upgrade Section of this manual for detailed 
instructions.  

 

Connecting the M10 to one M7 

Connecting one M7 to the M10 is simple; just connect the supplied serial cable to M10, the other end to the 
M7, and install the terminator plug on the loop thru connector on the M7

 

Below, an example of one M7 with the termination plug installed  
 

 

 

Connecting more than one M7 to the M10 

Connecting more than one M7 to the M10 is also simple; just connect the supplied serial cable to M10, the 
other end to the first M7, and install the terminator plug on the loop thru connector on the last M7.  In this 
case you may have to provide a short serial cable to connect the first M7 to the second if you have not 
ordered one from Bricasti. 

 

Below, an example of 2 M7s connected to one M10.  Top machine is unit #1 and has the M10 connected, an optional short serial loop 
connector connects to the lower #2 unit and termination plug installed on lower #2 unit.  

 

 

 

To connect more M7 to the chain, just loop from one to the next and terminate the last one.  The order in 
which the units are connected will determine the machine number sequence when using them from the 
M10.  First machine is #1, second one is #2 and so on up to 8. 

 

Power Requirements 

The M10 derives its DC power from the M7 it is connected to.  The M7 power supply is sufficient to 
operate the M10 with cable lengths up to 30 meters.  If your installation requires longer runs then an 
additional 12v DC power supply may be required to remotely power the M10.   If your installation has this 
requirement please contact your distributor for more details to source a suitable power supply and wiring 
diagrams. 

 

 

Summary of Contents for Bricasti M10 Owner's

Page 1: ...Owner s Manual M10 The Model Ten Remote Console Rev 2 03 10...

Page 2: ......

Page 3: ...contact your dealer for ordering the Bricasti part Bricasti Part number for the optional serial interconnect cable is M7 SC Precautions The Bricasti Design M10 is a rugged device with extensive electr...

Page 4: ...MA USA hereby declares on own responsibility the following products M10 Remote Console that is covered by this certificate and marked with the CE label conforms to the following standards EN 60065 Saf...

Page 5: ...can be proud of Use We designed the M10 for the Professional Audio Engineer Easy to use quick to get at great sounding presets hot keys to save that favorite program with a button push and a bright e...

Page 6: ...le to M10 the other end to the first M7 and install the terminator plug on the loop thru connector on the last M7 In this case you may have to provide a short serial cable to connect the first M7 to t...

Page 7: ...nnection and interconnecting M7s is specific in how it uses the wires in the cable Although the serial data and interface used for the M10 is to an RS422 standard the pin out is not so data error can...

Page 8: ...lower right to display what machine is being controlled Cursor Up Down Keys When in machine edit mode controls lower display selects reverb effect parameters program banks system parameter types regi...

Page 9: ...play 3 With 3 or 4 M7s connected the machine key is used in conjunction with the keys labeled 1 4 favorite keys in Program mode Press MACH and then the 1 key and this will select machine 1 Press MACH...

Page 10: ...to take when saving system setups Most users will more than likely connect the M10 to their M7s complete the installation and rarely change things But there is the possibility to move machines around...

Page 11: ...lay Feature When an M10 is connected to an M7 both sets of controls the front panel on the M7 and the M10 are both active and mirror each other Taking hold of the M7s controls will track on the M10 an...

Page 12: ...grade 1 Disconnect all audio and AC mains As you will be opening the M7 you must remove the AC power to protect against accidental shock and or component damage 2 Remove the top cover by removing the...

Page 13: ...nections have been disturbed 7 Power on test Before attaching the top cover you should carefully test the M7 and see that it does power up correctly so in the event there is a problem you don t have t...

Page 14: ...Notes 9...

Page 15: ......

Page 16: ...M10 The Model Ten Bricasti Design Ltd Bricasti Design com All rights reserved...

Reviews: