www.BrickElectric.com
setpara[134]=168;
Web access URL:
http://192.168.1.105/ setpara[135]=1;
Or Socket command text:
setpara[135]=1;
Web access URL:
http://192.168.1.105/ setpara[136]=106;
Or Socket command text:
setpara[136]=106;
(3) Select output channel one of target BEM11000 by:
Web access URL:
http://192.168.1.105/ setpara[173]=1;
Or Socket command text:
setpara[173]=1;
6.2 X-Connect Map Parameter List
All eight X-Connect channels can be setup by the following parameter list:
Parameter
Nr.
X-Connect
Channel
Para
Name
Description
Range
102
1
VWSL1
X-Connect CH1 input select
1 ~ 8
103
2
VWSL2
X-Connect CH2 input select
1 ~ 8
104
3
VWSL3
X-Connect CH3 input select
1 ~ 8
105
4
VWSL4
X-Connect CH4 input select
1 ~ 8
106
5
VWSL5
X-Connect CH5 input select
1 ~ 8
107
6
VWSL6
X-Connect CH6 input select
1 ~ 8
108
7
VWSL7
X-Connect CH7 input select
1 ~ 8
109
8
VWSL8
X-Connect CH8 input select
1 ~ 8
110
9
VWSL9
X-Connect CH9 input select
1 ~ 8
111
10
VWSL10
X-Connect CH10 input select
1 ~ 8
133
1
VWSIP11
X-Connect CH1 target IP 1
0 ~ 255
134
1
VWSIP12
X-Connect CH1 target IP 2
0 ~ 255
135
1
VWSIP13
X-Connect CH1 target IP 3
0 ~ 255
136
1
VWSIP14
X-Connect CH1 target IP 4
0 ~ 255
137
2
VWSIP21
X-Connect CH2 target IP 1
0 ~ 255
138
2
VWSIP22
X-Connect CH2 target IP 2
0 ~ 255
139
2
VWSIP23
X-Connect CH2 target IP 3
0 ~ 255
140
2
VWSIP24
X-Connect CH2 target IP 4
0 ~ 255
141
3
VWSIP31
X-Connect CH3 target IP 1
0 ~ 255
142
3
VWSIP32
X-Connect CH3 target IP 2
0 ~ 255