Bridge BRDSC01 v4
User Manual
16
Fire Topic Prefix
The device will append the partition number to this prefix to build the topic where the fire
state of the partition will be published.
For instance, if this parameter is set to DSC010000000001/Fire the fire state of partition 1 will
be published on topic DSC010000000001/Fire1, the fire state of partition 2 will be published
on DSC010000000001/Fire2 and so on and so forth.
Fire payload is 1 when active and 0 when inactive.
Trouble Topic
The device will publish the trouble status in this topic.
Trouble payload is 1 when trouble reported and 0 when no trouble.
Commands Topic
This is the topic the device will subscribe to receive the commands and messages to send to
the alarm system. Keys pressed on the virtual keypad will be also published on this topic.
Keep Alive interval (seconds)
If this parameter is greater than 0, the device will publish a keep alive message every time this
interval is elapsed.
The message payload depends on firmware version but usually includes a timestamp, the state
of the connection with the Alarm system and with MQTT brokers.
Keep Alive Topic
Is the topic where the keep alive message will be published.
Timer ON
If set to YES enables the timer feature. Default value is NO
For disarming alarm system with the timer, the Access Code, needs to be specified. (Please
refer to “Access Code” parameter on this section)
Be aware that disarming the alarm system with a timer could imply a
security risk.
Timer String
Is the string needed to program the timer feature.
Timer String format
Timer Strings contains 7 characters substrings including information about each action to be
performed, the target partition, and the moment these actions will be triggered.
First characters of the substring represent the day of the week, or the day combination when
the action will be triggered
. Day combination character list is as follows:
A: Monday
B: Tuesday