B Technical Specifications
Physical
Form Factor
19
00
2U rack mount
Overall Depth
717.6mm with bezel
Rack Depth Required
681.8mm
Height
86.8mm
Width
482.0mm with rack latches
Weight
23.8kg at maximum configuration
Recommended minimum
clearance for cooling
100mm on front and rear faces
Electrical
Input voltage
100–240V autoranging
Frequency
50–60Hz
Input current
10A–5A
Maximum power consumption
750W approx.
Environmental
Operational temperature
10
◦
C to 35
◦
C
Non-operational temperature
-40
◦
C to 65
◦
C
Humidity
10–80% non-condensing
Onboard Management
Interface
No. of interfaces
2
Physical
RJ45 (8P8C)
Speed
Auto-sensing 10 / 100 / 1000Mb/s
Standards
IPv4, IPv6, NTP, SNMP, DHCP
Onboard WAN Interface
No. of interfaces
0
Physical
RJ45 (8P8C)
Speed
Auto-sensing 10 / 100 / 1000Mb/s.
Feature Cards
No. of feature cards
Up to 4
Supported feature cards
WAN 1GbE
WAN 10GbE
WAN 40GbE
WAN 100GbE
iSCSI 1GbE
iSCSI 10GbE
iSCSI 40GbE
iSCSI 100GbE
Fibre Channel 16Gb
Fibre Channel 32Gb
18