Care and Maintenance

To prevent corrosion inside the tank, the condensation must be 

drained at the end of every workday. Be sure to wear protective 

goggles. Relieve the air pressure in the system and then open the 

drain valve on the bottom of the tank.

Drain the

tank

Check the 

relief valve

Test for 

leakage

Storage

Pull the relief valve on the ring daily to ensure that it is 

operating properly and to clear the valve of any possible

obstuctions.

Check all connections to see if tight. A small leak of any of part 

(the tank, hoses, pipe connections or transfer tubes) will reduce 

the unit's performance.

Spray a small amount of soapy water around the area of the 

suspected leak with a spray bottle. If bubbles appear, repair or 

replace the faulty component. Do not over tighten any connections.

Before storing the unit for a long period, use an air blow gun to 

clean all dust and debris from the compressor. Disconnect and coil 

the power cord up. Pull the pressure relief valve to release all 

pressure from the tank. Drain all moisture from the tank. Cover 

the entire unit to protect it from moisture and dust.

OPEN 

CLOSE

WARNING : 

To avoid personal injury, always shut off and unplug the unit and relieve all air pressure 

    from the system before performing.

Regular maintenance will ensure trouble-free operation.

Not 

for 

Reproduction

Summary of Contents for 074061-00

Page 1: ...product It contains important information for your safety as well as operating and maintenance advice BRIGGS STRATTONCORPORATION MILWAUKEE WISCONSIN U S A 1 GAL PORTABLE OIL FREE AIR COMPRESSOR Produ...

Page 2: ...brand When operated and maintained according to the instructions in this manual your Briggs Stratton air compressor will provide many years of dependable service You can contact Briggs Stratton Custom...

Page 3: ...code below from your mobile device Product updates Helpful maintenance and usage tips Discounts and offers on future products product online Whether you absolutely love your new product or have a sug...

Page 4: ...ance Troubleshooting Exploded View Parts List Limited Warranty Safety Information 4 SAVE THESE INSTRUCTIONS This manual contains important safety and operating instructions Read all instructions and f...

Page 5: ...or unsafe Warning Bursting Hearing Fire The safety alert symbol indicates a potential hazard to personal injury A signal word DANGER WARNING or CAUTION is used with the alert symbol to designate a deg...

Page 6: ...k of re could result in death or serious injury Do not operate with pressure switch or safety valve set above maximum allowable working pressure Hot compressor surfaces could result in serious injury...

Page 7: ...rtsDiagram 7 F Air Tank E Pressure Relief Valve D Tank Pressure Gauge G Drain Valve B ON OFF Switch A Electric Motor Pump H Power Cord C Air Line Outlet A B D C F G E H N o t f o r R e p r o d u c t i...

Page 8: ...the system When the pressure reaches the preset level the pressure switch will not shut down the motor it will automatically pop open or you can pull the ring on the valve to open AIR TANK The tank i...

Page 9: ...he air line outlet C clockwise until it stops Turn on the ball valve on the air line outlet counterclockwise Ball Valve drain 9 Operating Instructions OPEN CLOSE B G H B E B H C C E G H B N o t f o r...

Page 10: ...er tubes will reduce the unit s performance Spray a small amount of soapy water around the area of the suspected leak with a spray bottle If bubbles appear repair or replace the faulty component Do no...

Page 11: ...r assembly 9 Replace compressor assembly Pressure relief valve opens 1 Tank pressure exceeded normal rating pressure 2 Pressure switch stuck 1 Replace pressure switch 2 Replace pressure switch Motor w...

Page 12: ...RIGGSandSTRATTON COM BRIGGS STRATTON is a trademark of BRIGGS STRATTON CORPORATION and is used under license to Alton Industry Co Ltd Alton Industry Co Ltd warrants this Briggs Stratton brand product...

Page 13: ...T 18 AWG 72 in Length NOTE Avoiduseofextensioncords Ifuseofanextensioncordcannotbeavoided thecordshouldbeaminimum wiresizeof12AWGandnolongerthan30feet Useonlya3 wireextensioncordthathasa3 bladegroundi...

Page 14: ...BRIGGSandSTRATTON COM 14 ExplodedView N o t f o r R e p r o d u c t i o n...

Page 15: ...tapping Screw M3 X 6 Circuit Board Bolt M5 X 12 Fixing Plate Transfer Tube Fitting Pipe Check Valve Plug 14 15 16 Check Valve Spring Shroud Bolt M6 X 20 1 1 1 1 1 1 2 1 2 1 1 2 1 ON OFF Switch Motor...

Reviews: