14
BRIGGSandSTRATTON.COM
Inspect / Clean Air Filter
Use the following steps to check and clean the compressor’s
internal air filter.
1. With air tank fully pressurized (
ON - OFF
switch in
ON
position and motor stopped), push
ON - OFF
switch to
OFF
position. Disconnect power cord from outlet.
2. Use phillips screwdriver to remove screw (
H
) holding
air filter cover (
J
) on compressor housing (
K
). Remove
air filter cover.
3. Remove air filter media (
L
).
IMPORTANT
: DO NOT operate compressor with air filter
media removed.
4. If dirty, use compressed air to dislodge dirt from air
filter media. Also, blow debris out of air filter cover and
compressor filter housing.
NOTE:
DO NOT use liquid solvents to clean filter media.
5. Replace air filter media in compressor filter housing.
6. Position air filter cover over air filter media. Use phillips
screwdriver to secure cover with screw.
NOTE
: Replace air filter media if it is extremely dirty.
Inspect Safety Labels
As often as desired or at least yearly, inspect all labels
applied to the air compressor. All safety labels should be
present and readable. If any safety label is missing or
illegible, obtain a replacement from an authorized service
center or call the air compressor helpline at
(800) 743-4115
.
Storage
Before you store your air compressor, make sure you
perform the following:
1. Review
Maintenance
and perform scheduled
maintenance as necessary.
2. Push
ON - OFF
switch to
OFF
and unplug unit.
3. Turn pressure control knob counterclockwise until knob
turns freely.
4. Remove air tool or accessory.
5. Pull ring on safety valve and drain air from air tank to
reduce air pressure. Release safety valve ring.
6. Drain remaining air and water from tank by opening
drain valve fully counterclockwise.
7. Rock unit forward and back to agitate water as it drains
to obtain a more thorough emptying action.
8. After water has been drained, close drain valve fully
clockwise.
9. Protect electrical cord and air hose from damage (such
as being stepped on or driven over).
10. Store air compressor in clean, dry, indoor location.
H
J
L
K
WARNING
Compressed air stream from hose or tank drain
can cause soft tissue damage to exposed skin
and can propel objects leading to severe injury
and / or property damage.
• DO NOT direct air stream at self or others.
• Always wear ANSI Z87.1 approved safety glasses with side
shields.
WARNING
Compressed air stream from hose or tank drain
can cause soft tissue damage to exposed skin
and can propel objects leading to severe injury
and / or property damage.
• DO NOT direct air stream at self or others.
• Always wear ANSI Z87.1 approved safety glasses with side
shields.