Use and Maintenance Manual – VER. 2016-02
Page 11
Note: The [P7]
, [P8] Start
and [P10] Stop
keys are not used to access settings, programs or
Menus.
13.2 STANDARD, SERVICE, STAND-BY operating modes
The machine features three operating modes:
STANDARD mode. This mode is enabled when the machine is turned on and allows using the machine to perform wheel
balancing.
SERVICE mode. In this mode, various programs are available for performing settings (such as measurements in grams or
ounces) or checking the machine operation (such as calibration).
STAND-BY mode. After 5 minutes without user activity, the machine automatically switches to STAND-BY mode to reduce
electrical consumption (both with wheel guard raised or lowered). The STAND-BY green LED on the control panel flashes
when the machine is in this operating mode. All acquired data and settings are retained in STAND-BY mode. When in
SERVICE mode, the machine cannot be switched to STAND-BY mode.
To exit STAND-BY mode, proceed with one of the following options:
Press any key (with the exception of [P7]
);
Turn manually the wheel;
Remove the Distance and Diameter sensor from the rest position.
Note: The machine will also exit STAND-BY mode by pressing the [P8] Start
. In these cases spinning will also be started
up immediately.
14. TEMPORARY DISTANCE/DIAMETER SENSOR DISABLING
If the machine displays the error code
Err 016
“dis out”
(Distance/Diameter sensor not in the rest position) at switching on,
although being in rest position, it means that an anomaly occurred in the acquisition system.
It is possible to temporarily disabling the Diameter/Distance sensor by pressing keys [F+P2]
. The
LED
on the control board will light up and flash indicating the automatic acquisition of Diameter/Distance is disabled
and the machine is ready to be used.
As it is not possible to use the automatic acquisition system, the wheel dimensions must be entered manually. By turning the
machine off and back on again, the error code will re-appear and you will once again need to proceed as described above.
If the automatic acquisition system is malfunctioning and it blocks the machine in a permanent acquisition function, the temporary
disabling could be done also after the machine is switched on.
15. MACHINE CALIBRATION
To operate properly, the machine must be calibrated. Calibration allows storing the mechanical and electrical parameters specific
to each machine so as to provide the best balancing results.
Summary of Contents for VULTURE BP46