Use and Maintenance Manual – VER. 2016-02
Page 29
19. UTILITY PROGRAMS
Utility programs are available only in NORMAL mode.
19.1 Selection of the imbalance display resolution
The machine has two wheel imbalance display resolutions. The two resolutions are defined as X1 (high resolution) and X5 (low
resolution).
The resolution with which the imbalances of the wheel are displayed varies depending on the weight unit of measurement as
indicated in table T19.1.
Table T19.1: Display resolution
Set resolution
Imbalance unit of
measurement
Display resolution
Notes
X1
(High resolution)
Grams
1 gram
Ounces
0.1 ounces
X5
(Low resolution)
Grams
5 grams
The X5 resolution is set by default at start-up
Ounces
0.25 ounces
To view the X1 resolution imbalance (high resolution), press [F+P1]
. The machine will display the
message visible in Picture F19.1 for one second and the LED next to the button lights up. Imbalance values are now displayed in X1
resolution (high resolution).
Picture F19.1: Enabling imbalance display in high resolution
To return to viewing in X5 resolution (low resolution), press [F+P1]
. The machine will display the
message visible in Picture F19.2 for one second and the LED next to the button will turn off. Imbalance values are now displayed in
X5 resolution (low resolution).
Picture F19.2: Disabling imbalance display in high resolution
19.2 Selection of the static imbalance display
To view the static imbalance, press [F+P2]
. The machine will show the static imbalance value on the
display as seen in picture F19.3, and the LED next to the button lights up.
Picture F19.3: Static imbalance display enabled. The right display indicates the entity of the static imbalance