Use and Maintenance Manual – VER. 2016-02
Page 33
To display the current unit of measurement, briefly press [P5]
. The unit selected is displayed for three seconds, after
which the machine returns to display
Ser Ser
.
Press any key to exit the display of the current unit without waiting for three seconds.
CHANGE OF CURRENT UNIT
To change the current unit of measurement, keep [P5]
pressed for three seconds. The new unit of measurement will
be displayed, after which the machine returns to display
Ser Ser
.
The unit of measurement selected is maintained even after turning off the machine.
[P6] Select the imbalances view threshold
This button allows you to edit the imbalance display threshold. This procedure is intended for technical support personnel,
therefore it is not described in this manual.
[P9] Not used
This button is not currently used in SERVICE mode.
[F+P1] Not used
This button is not currently used in SERVICE mode.
[F+P2] Select weights material Fe/Zn or Pb
This button allows you to select the balancing weight material. The options available are listed in table T20.1. The selection of the
material type slightly changes the balancing results because the weights in Iron/Zinc are lighter than those in Lead and therefore
are larger. The machine takes account of these differences when calculating the imbalance.
Table T20.1: Balancing weights materials
Option
Type of balancing weight material
Notes
Fe
Iron or Zinc
This material has been set by default.
Pb
Lead
In some countries (such as those of the European Community), Lead
weights are prohibited by law.
DISPLAY OF CURRENT TYPE OF MATERIAL
To display the current type of material briefly press [F+P2]
. The type of material currently selected
is displayed for three seconds, after which the machine returns to display
Ser Ser
.
Press any key to exit the display of the current type of material without waiting three seconds.
CHANGE OF CURRENT TYPE OF MATERIAL
To change the current type of material hold down
for three seconds. The new type of material will
be displayed, after which the machine returns to display
ing
Ser Ser
.
The type of material selected is maintained even after the machine has been turned off.
Note: if Lead has been selected as material, at every machine start-up a message indicating the selection of this material will appear
for one second after the initial test. This signal will not be viewed if Iron/Zinc is selected as material.
[F+P3] Exit the SERVICE mode
This button allows the machine to exit SERVICE mode and return to NORMAL mode.
Summary of Contents for VULTURE BP46