background image

26

Global RS232 can be flexibly set to any of the RS232 port, whether remote receiver side or the
local side.

Web GUI

How to enter Web GUI

Type in IP address "192.168.0.200" in web browser to enter the Web GUI. First login will enter
the default Guest account, in which you can only check limited system info and perform simple
source switching.

Admin account

Logout the guest account and longin admin account for full access.

Account Name: admin

Password: 1234

Summary of Contents for 16x16

Page 1: ...1 18Gbps 4K 60hz HDMI 2 0 HDbaset matrix modular version ...

Page 2: ...rce sink and CAT cable 5 To reduce the interference among the unshielded twisted pairs of wires in CAT cable do not run HDBaseT Zone Cat5e 6 6a cabling with or in close parallel proximity to mains power cables Shielded CAT cables can be used to improve EMI problems which is worsen in long transmission 6 Because the quality of the CAT cables has the major effect on how long the transmission limit c...

Page 3: ...ol Description 8 Application Diagram 9 Specifications 10 Package Contents 10 RS 232 Pin Assignment 11 RS232 and Telnet Commands 11 GUI Control 14 Web GUI 26 Maintenance Warranty Policy Limitations of Warranty Exclusive Remedies RMA Policy Standard Replacement Once you have obtained an RMA number Please note ...

Page 4: ...eb GUI This pro matrix series provides the most flexible and cost effective solution in the Audio Video market It has been specifically designed to operate in challenging AV environment Features 19inch 4U modular design flexible horizontal I O cards 16x HDMI inputs 16x HDBaseT outputs 8 mirrored HDMI outputs Supports 4K 60Hz 4 4 4 HDR HLG and full 3D 16x HDBaseT output support transmitting 1080p u...

Page 5: ...Input Output channel when Input Output is high than 9 This button also can be used to control cursor to Left under MENU editable status 7 HDMI Input Output multiple button 5 Press to select Input 5 or Output 5 Or combine with other button to select Input Output channel when Input Output is high than 9 This button also can be used to control cursor to Up under MENU editable status 8 All Button for ...

Page 6: ... or Output 6 to 8 Or combine with other button to select Input Output channel when Input Output is high than 9 15 HDMI Input Output multiple button 9 Press to select Input 9 or Output 9 Or combine with other button to select Input Output channel when Input Output is high than 9 This button also can be used to control cursor to Right under MENU editable status 16 HDMI Input Output multiple button 0...

Page 7: ...use with a sound system or multi channel zone amplifier Audio outputs follow the corresponding HDBaseT outputs e g Audio out 1 follows HDBaseT output 1 6 IR Output 1 to 16 3 5mm mono phone jack connect to IR emitter cable 7 Global IR Output 3 5mm mono phone jack 8 Global IR Input 3 5mm mono phone jack 9 Power Switch Power on off the matrix 10 DC Power Input Connect to DC power supply included in p...

Page 8: ...to 8 of inputs then INPUT Y switched to ALL OUTPUTS C Mirror all inputs and outputs Ex Input 1 to output 1 input 2 to output 2 etc Press PTP button in Zone OUTPUT EDID Set Up A Fixed EDID to INPUT Y ALL Press 1080I 1080P 3D 4K Press 2 0CH 5 1CH 7 1CH INPUT Y ALL button in Zone INPUT B Copy EDID of OUTPUT X to INPUT Y ALL Press COPY button Press OUTPUT X button Press INPUT Y ALL button C User defin...

Page 9: ...9 Application Diagram ...

Page 10: ...reo jack IR Output ports 17x 3 5mm stereo jack RS232 series port 1x DB9 connector female 16x3 pin phoenix terminal connector Dimensions W x D x H 440mm x 420mm x 180mm without feet Shipping Weight 14 6KG Operating Temperature 32 F to 104 F 0 C to 40 C Storage Temperature 4 F to 140 F 20 C to 60 C Power Supply 100V 240V Package Contents 1 1x 8x8 HDbaset matrix 2 1x Power Supply 3 1x Power Cord 4 1x...

Page 11: ... On Power Save State 6 IR ON OFF Set System IR Control On Or Off 7 KEY ON OFF Set System KEY Control On Or Off 8 BEEP ON OFF Set Onboard Beep On Or Off 9 LCD ON OFF Set LCD Always On Or Auto Turn Off In Power On State 10 RSB x Set RS232 Baud Rate to X bps x 0 115200 1 57600 2 38400 3 19200 4 9600 11 RESET Reset System To Default Setting Should Type Yes To Confirm No To Discard 12 RESET ALL Reset S...

Page 12: ...h Output 08 22 EDID xx CP yy Set Input xx EDID Copy From Output yy 23 EDID xx DF zz Set Input xx EDID To Default EDID zz xx 00 All INPUT Port 01 08 INPUT Port yy 01 08 OUTPUT Port zz 00 HDMI 1080p 60Hz Audio 2CH PCM zz 01 HDMI 1080p 60Hz Audio 5 1CH DTS DOLBY zz 02 HDMI 1080p 60Hz Audio 7 1CH DTS DOLBY HD zz 03 HDMI 1080i 60Hz Audio 2CH PCM zz 04 HDMI 1080i 60Hz Audio 5 1CH DTS DOLBY zz 05 HDMI 10...

Page 13: ...4 Remote HDBT Receiver IR Input xx 25 Global All Ir In Add xx To Current Setting Remove xx From Current Setting 27 MXRS xx TO yy Local RS 232 xx Route To Remote HDBT yy xx 09 Global RS 232 yy 00 Not Connect To Any RS 232 yy 09 16 Remote HDBT Receiveryy 09 16 Remote HDBT Receiver 28 MXSTA Print Matrix IR And RS 232 Connect State 29 AUD RX xx ORG Input Port xx Use Original Received HDMI DVI Signal 3...

Page 14: ...x Controller vx x exe to the PC which is used to control the Matrix by RS232 COM or TCP to complete installation Preparation 1 Connect PC and Matrix by RS232 cable or UTP cable 2 Power up Matrix It will take about 5 seconds to be ready with Di beep sound 3 Double click 8x8 HDMI Matrix Controller vx x exe icon to run it Common information Click to select tab page 1 COM port or TCP connect status 2 ...

Page 15: ...lick to connect or disconnect PC and Matrix Connection will be established automatically before control commands sending 7 Click to refresh device status include device information displayed in area and Input output port connection status in area NOTE Tab pages cannot be changed during control command is processing 8 To enable or disable Input output tags displaying when setting buttons on Setting...

Page 16: ...ill obtain IP automatically Otherwise set Static IP mode and designate a useable IP for Matrix device 3 Set IP address not editable when Auto IP mode selected Note The last IP BYTE s range is 2 252 4 Matrix device MAC address 5 Click OK to set configuration If configuration is set OK Matrix devices will be searched out again 6 Click to Close the window and configuration cancelled Port Tag page 6 5...

Page 17: ... device when COM control mode selected 3 Input output port tags can be set for respective Matrix device according to device s MAC address Edit Input port tags After action of edit form will pop up as below Define tags for respective Input port then devices connect the Input ports can be easily remembered Click buttons with caption to delete tag which is no use any more if tag is still used by any ...

Page 18: ...embered Click buttons with caption to delete tag which is no use any more if tag is still used by any other Output port delete action will be discarded Setting page 1 LED which displays Input number for respective Output port 2 Click to select Input port for respective Output port 3 Click to select previous or next Input port for respective Output port 6 7 5 4 1 3 2 ...

Page 19: ...re setting item 7 Set selected pre setting item to Matrix NOTE When Change to this Setting page software will try to refresh source selection status of Output port Pop up tag messages When Display Input Output tags when focus setting buttons checkbox on General page is checked and Input output port tag has been defined tag messages will pop up like as ...

Page 20: ... up like as All Outputs All Outputs from same Input 1 Output to 7 Outputs Set current Output where mouse right clicked and the next x 1 x range is from 1 to 7 set total x Outputs at the same time Output s from same Input Port to Port Output1 from Input1 Output2 from Input2 Output3 from Input3 etc ...

Page 21: ... form will pop up as below 1 Pre Setting name 2 Set all Output ports from same Input 3 Select Input for respective Output EDID control page 1 Set EDID mode for selected Input port or All Input ports click Set button to complete action 1 2 3 6 7 8 5 4 3 2 1 ...

Page 22: ...pen EDID binary file and display in grid 6 Download EDID content which displayed in grid to selected Input port or All Input ports click Download button to complete action When User1 Memory User2 Memory selected download EDID content to respective memory then User1 User2 EDID mode can be set 7 EDID content displaying grid NOTE EDID content displayed in grid is read only 8 Click to clear EDID conte...

Page 23: ... messages displayed in the memo box NOTE If failure occurs during upgrading firmware process the following steps SHOULD be done sequentially to establish next upgrading procedure 1 Power down the Matrix 2 Close the 8x8 HDMI Matrix Controller 3 Re power up the Matrix then wait for 10 seconds to ensure the Matrix is ready 4 Run 8x8 HDMI Matrix Controller open firmware file and upgrade again 5 4 3 2 ...

Page 24: ...nput and stay there when signal detected Set Audio Source for Input Each input audio source can be from the original HDMI HDBT input analog L R embedded or Analog embedded when DVI 1 Choose original the audio will be from the HDMI HDBT input 2 Choose Analog L R In embedded the local L R In will remove the original audio from the HDMI HDBT input and be embedded 3 Choose Analog embedded when DVI whe...

Page 25: ...of remote HDBT receiver 8 Global All IR In Global All IR In can be set flexibly to any specific IR output or all of the IR outputs Global All IR Out Global All IR Out can be set flexibly from any specific IR output or all of the IR inputs Global All IR In can be set to loop to Global All IR Out Global RS 232 Route ...

Page 26: ...ter Web GUI Type in IP address 192 168 0 200 in web browser to enter the Web GUI First login will enter the default Guest account in which you can only check limited system info and perform simple source switching Admin account Logout the guest account and longin admin account for full access Account Name admin Password 1234 ...

Page 27: ...terface Status Page System info and Web UI info including Model Number Firmware Version Power Status IP status IP address Gateway Subnet Mask MAC Address and UI Version You can turn ON OFF the matrix thru click the power icon on the bottom ...

Page 28: ...28 Config Page You can set DHCP IP Address Gateway and Subnet Mask you can aslo custom name for the Inputs such as Sky STB SONY DVD SAMSUNG DVD etc and Outputs such Room 1 Room 2 Room 3 etc Output Page ...

Page 29: ...This page also shows the connect status for HDMI HDBaseT ports Input Page You can set the Input Source priority Force HDMI Force HDBT Auto HDMI or Auto HDBT check the current input source and check the HDMI HDBT connect status Preset Page There re several preset input output settings for you to choose ...

Page 30: ...30 EDID Page You can select build in EDID patterns for each input and select EDID priority for HDMI HDBT ...

Page 31: ...31 Audio Page You can select audio source for each output set audio delay values and control audio volume IR RS232 Page You can set routing path for IR RS232 ...

Page 32: ...32 Users Page You can creat edit and remove account PS Admin account can t be deleted Custom Account Example for create Custom Account Gordon_Gong ...

Page 33: ...33 ...