CHARACTERISTICS
Modern, energy saving and durable LED luminaires in a form of flat panel designed for
installation in suspended ceilings with modules of 600 x 600mm or gypsum-board by special
mounting clips UM-3 (not included in the set with luminaire).
OPTIMA 60 luminaires are equipped with LEDs SMD type, which allow high energy saving
comparing to traditional luminaires, keeping the same lighting parameters. High colour
rendering index CRI, close to natural light, provides vivid rendering of the environment.
Light colour: neutral white - 4000K.
LEDs lifespan: 50 000 hours.
LED external driver included in the set.
Driver’s supply voltage:
220-240V AC, 50/60Hz.
Wires dimensions according to [Fig.1.].
1. Fix the UM-3 mounting clips to the luminaire [Fig.4.] and [Fig.5.].
2. Cut out proper mounting hole in the ceiling.
3. Connect LED panel with LED driver by cable with plug [Fig.2.].
4. Connect the LED driver to the mains ~230V, 50/60Hz [Fig.3.].
5. Place the luminaire in the suspended ceiling [Fig.6.].
Installation in suspended gypsum board ceilings by special UM-3 mounting
clips (not included in the set with luminaire)
Installation in suspended ceilings with modules of 600 x 600mm
INSTALLATION AND OPERATING MANUAL
OPTIMA 60 – LED panel for recessed installation in suspended ceilings
OPTIMA 60
EN
Panel
ELUM Sp. z o.o.
ul. Wilanowska 1A, 05-520 Konstancin-Jeziorna, Poland
www.elum24.pl
TECHNICAL DATA
135mm
Fig.1.
OPTIMA 60 luminaire
LED driver
130mm
120mm
➢
➢
230V AC
LED driver
Fig.2.
230V AC; 50/60Hz
brown - phase (L) blue - neutral (N)
N
L
Fig.3.
LED driver
Fig.6.
LED driver
OPTIMA 60 luminaire
Suspended
ceiling
595mm
595mm
30mm
CONSTRUCTION
LED panel’s body is made from aluminum profiles in a form of frame covered with metal
shield from the upper side. Milky cover is made of polystyrene (PS).
APPLICATION
Specially recommended for illumination of computer rooms, meeting rooms, lecture halls,
offices, institutions and other public facilities, as well as a decorative lighting, in hotels,
guest houses, that raises aesthetic value of the area.
This symbol stands for selective collecting of the electrical and electronic equipment,
therefore, this product cannot be treated as other household’s waste. It has to be left
at a special used-equipment collection point. The appropriate dealing with the
collection of used electrical and electronic equipment is crucial, especially if the
equipment includes dangerous components which have a negative influence on the
environment and on the health of people.
Model
OPTIMA 60
Power of the luminaire
40W
Supply voltage
220 ÷ 240V AC
Frequency
50/60Hz
Beam angle
120°
Power factor (cos φ)
0,9
Protection class
IP 20
Protection class
I
LEDs type
SMD
Light colour
neutral white
Correlated colour temperature
4000K
Colour rendering index (CRI)
80
LEDs lifespan*
50 000 hours
Luminous flux of the luminaire**
3400 lm
Ambient temperature
-10°C ÷ +40°C
Weight
1,80kg
* provided parameter is based on LEDs manufacturer’s data
** parameter is provided with ±5% tolerance margin
SAFETY AND MAINTENANCE
1. Installation of the luminaire should be done by the certified and experienced electrician.
Before starting the installation you must absolutely turn off the main power supply,
where the luminaire should be connected to, to avoid accidental voltage connection!
2. Electrical cables must be connected according to the instruction and regulations in
force.
3. To keep the optimal technical parameters of the luminaire the periodical maintenance
should be carried out. Before cleaning the product, disconnect it from power supply.
Ignoring this warning can cause danger of electric shock. The housing of the luminaire
should be cleaned by generally available cleaning supplies and also dried with a soft
cloth. Do not use corrosives chemicals and solvents. Do not use stream of water under
pressure.
CAUTION!
1. Terminal block for current ~230V is not included. An advice from qualified person
is needed for installation.
2. Light sources are not replaceable; once light sources are used up, full luminaire
should be replaced.
3. For proper operation of OPTIMA 60 luminaire, it is forbidden to cover the luminaire
and LED driver with thermal insulation material!
4. We reserve the right to apply changes in the construction of the product.
5. The information included in this document may undergo changes without warning.
Possible changes will be taken into consideration while working with other issues
of the instructions for use or complementary documents.
6. We take no responsibility for faults resulting from non-compliance with the above
instructions. According to article 568 pt 1 of the Polish Civil Code, the right resulting
from a warranty for physical defects are extinct after the lapse of 2 (two) years after
delivery of the luminaire to the Buyer.
1. Take out the coffer ceiling module from the suspended ceiling.
2. Connect LED panel with LED driver by cable with plug [Fig.2.].
3. Connect the LED driver to the mains ~230V, 50/60Hz [Fig.3.].
4. Place the luminaire in the suspended ceiling frame.
Fig.4.