5HQRYHQW([FHOOHQW)
Chapter 3 Version
1 Service connector
Computer connection for service purposes.
2 Display and 4 control buttons
Interface between user and control electronics.
3 Control board
Contains the control electronics for the basic functions.
4
([WUDFWDLU¿OWHU
)LOWHUVDLUÀRZIURPGZHOOLQJ
5 Preheater
Heats up the outdoor air when there is a risk of freezing for the heat exchanger
6 Heat exchanger
Ensures heat transfer between input and output air
7
6XSSO\DLU¿OWHU
Filters outdoor are supplied to the dwelling
8 Bypass valve
Sends the air through or around the heat exchanger (For the 4/0 this
valve is in the upper part of the appliance)
9 Outdoor temperature sensor
Measures outside air temperature.
10 Indoor temperature sensor
Measures the dwelling air temperature
11 Condensate discharge
Connection condensate discharge (Kit comes separately with the appliance)
12 Extract fan
Discharges air from the dwelling to the atmosphere.
13 Supply fan
Feeds fresh air into the dwelling.
14 Modular connector multiple switch X2
&RQQHFWLRQVIRUFDEOHWRPXOWLSOHVZLWFKLIGHVLUHGZLWK¿OWHULQGLFDWRU
15 Connector eBus X1
Connection for eBus control
16 Connector X15
Contains the various control inputs and outputs; only for Plus version
17 Connector X14
&RQQHFWLRQSRVWKHDWHURQO\IRU3OXVYHUVLRQDFFHVVLEOHDIWHUWDNLQJRႇWKH
display cover)
18 Mains cable 230 V
Gland power cable 230 volt
19 Connection to postheater
Gland 230 V cable to postheateror extra preheater; only for Plus version
Rear view display cover
(Plus version)
([SORGHGYLHZDSSOLDQFH
1
2 3
4
5
6
7
9
10
8
11
12
13
19
18
17
14
15
16