Renovent Excellent 450 614784-F
Chapter 8 Fault
8.1 Trouble shooting
When the appliance control system detects a fault, it is indi-
cated on the display with a spanner symbol, possibly together
with a fault code.
The appliance makes a distinction between a fault at which the
appliance keeps running (limitedly) and a serious (locking) fault
DWZKLFKERWKIDQVDUHVZLWFKHGRႇ
In case of locking fault, the settings and readings menu is
VZLWFKHGRႇDVZHOODQGRQO\WKHVHUYLFHPHQXLVDYDLODEOH
The appliance remains in this fault mode until the problem in
question has been solved. Then the appliance will reset itself
(auto reset) and the display will once more show the opera-
tional mode.
The fans are controlled on the basis of the value of the pres-
sure sensors mounted on the control board. For each fan 2
pressure hoses run to the control board. If these hoses are
not connected as prescribed, or if they are leaking or blocked,
a wrong pressure will be measured so the fans can no longer
be controlled correctly. In case of doubt on the correct perfor-
mance of the appliance, check the pressure hose connections.
Fault E999
If, when the appliance is powered up directly to message
E999
appears on the display, the mounted control board is not suit-
able for this appliance or the dip switches on the control board
are set incorrectly.
For the location of the dip switches see § 10.1.
In that case, check whether the dip switches on the control
board are set as shown in the drawing of the dip switches set-
tings; if they are, and the message E999 still appears, then
replace the control board by a board of the correct type.
Locking fault
When the appliance detects a locking fault, it will no longer
work. The (permanently lighted) display shows the fault symbol
(spanner) together with fault code. The red LED on the multiple
switch (if applicable) will be blinking. Contact the installer to
remedy this fault. A locking fault cannot be remedied by taking
WKHYROWDJHIURPWKHDSSOLDQFH¿UVWWKHIDXOWPXVWEHVROYHG
8.2 Display codes
1RQORFNLQJIDXOW
When the appliance detects a non-locking fault, it will still keep
running (limitedly). The display does show the fault symbol
(spanner).
Renovent
Excellent 450
typ 4/0
Renovent
Excellent 450
typ 4/0 Plus
Warning
When working on the appliance, always take the voltage from the appliance by pulling the power plug.
Summary of Contents for Renovent Excellent 450
Page 1: ...Renovent Excellent 450 Plus WWW BRINKAIRFORLIFE NL 614784 F INSTALLATION INSTRUCTIONS English ...
Page 2: ......
Page 8: ... 5HQRYHQW FHOOHQW ...
Page 45: ......