22
5HQRYHQW([FHOOHQW)
Chapter 8 Fault
Fault
code
Cause
Action appliance
Action installer
E100
Pressure sensor supply fan
defective.
Red pressure hoses blocked
RU³NLQNHG´
- Switches to constant rpm control.
- The preheater switches on at outdoor
temperatures below 0°C.
Take the voltage from the appliance.
Check the red pressure hoses (and
pressure tubes) for fouling, kinking
and damage.
E101
Pressure sensor extract fan
defective.
Blue pressure hoses blocked
RU³NLQNHG´
- Switches to constant rpm control.
- The preheater switches on at outdoor
temperatures below 0°C.
Take the voltage from the appliance.
Check blue pressure hoses (and
pressure tubes) for fouling, kinking
and damage.
E103
(non-locking
fault)
Bypass fault .
- None.
&XUUHQWWRRORZĺVWHSSHUPRWRUQRW
FRUUHFWO\FRQQHFWHGRUHႇHFWLYH
&XUUHQWWRRKLJKĺVKRUWFLUFXLWLQZLU
-
ing or stepper motor).
Take the voltage from the appliance.
Check connection stepper motor;
replace wiring or stepper motor.
E104
(locking
fault)
Extract fan defective.
-
%RWKIDQVDUHVZLWFKHGRႇ
-
3UHKHDWHUVLVVZLWFKHGRႇ
- If applicable: Postheater(s) is switched
Rႇ
- Restart every 5 minutes.
Take the voltage from the appliance.
Replace extract fan.
%XWYROWDJHEDFNRQDSSOLDQFH)DXOW
will automatically be reset.
Check cabling.
E105
(locking
fault)
Supply fan defective.
-
%RWKIDQVDUHVZLWFKHGRႇ
-
3UHKHDWHUVLVVZLWFKHGRႇ
- If applicable: Postheater(s) is switched
Rႇ
- Restart every 5 minutes.
Take the voltage from the appliance.
Replace.
3XWYROWDJHEDFNRQDSSOLDQFH)DXOW
will automatically be reset.
Check cabling.
E106
(locking
fault)
The temperature sensor that
measures the outdoor tem-
perature is defective. .
-
%RWKIDQVDUHVZLWFKHGRႇ
-
3UHKHDWHUVLVVZLWFKHGRႇ
- Bypass closes and is blocked.
Take the voltage from the appliance.
Replace temperature sensor.
Put voltage back on appliance; fault
will automatically be reset.
E107
(non-locking
fault)
The temperature sensor that
measures the temperature of
the extract air is defective.
- Bypass closes and is blocked.
Take the voltage from the appliance.
5HSODFHLQGRRUWHPSHUDWXUH
sensor.
E108
(non-locking
fault)
If present: The temperature
sensor that measures the ex-
ternal temperature is defective.
-
3RVWKHDWHULVVZLWFKHGRႇ
- If applicable: Geo heat exchanger is
VZLWFKHGRႇ
5HSODFHH[WHUQDOWHPSHUDWXUH
sensor.
E109
(non-locking
fault)
Fault on connected CO
2
sen-
sor
- Appliance continues to operate
Take the voltage from the appliance.
5HSODFH&2
2
-sensor; Correct setting
dipswitches of new CO2 sensor
Put voltage back on appliance; fault
is automatically reset.
E111
(non-locking
fault)
If present: The RH-sensor that
measures the huminity is de-
fective.
- Appliance continues to operate
Take the voltage from the appliance.
Replace RH-sensor.
E999
(locking
fault)
Dip switches on control board
not set correctly.
- Appliance does nothing; red fault LED
on multiple switch is not activated
either.
3XWGLSVZLWFKHVLQFRUUHFWSRVLWLRQ
(see § 8.1).
1RWH
If mode 2 of a multiple switch does not work, the modular connector of the multiple switch has been connected the wrong way round.
&XWRႇRQHRIWKH5-FRQQHFWRUVWRWKHPXOWLSOHVZLWFKDQGPRXQWDQHZFRQQHFWRUWKHRWKHUZD\URXQG
(non-locking
fault)
(non-locking
fault)