Important Safety Information
• Please read these instructions thoroughly and retain for future use.
• All products manufactured and supplied by Bristan are safe provided they are installed,
used correctly and receive regular maintenance in accordance with these instructions
• If you are in any doubt about your ability to install this product safely you must
employ the services of an experienced qualified plumber.
• Remove all packaging and check the components for damage before starting
installation.
• This product must not be modified in any way as this will invalidate the guarantee.
• These fittings need to be installed in accordance with and meet the requirements of the Water
Supply (Water Fittings) Regulations 1999 and Scottish Byelaws 2004.
General Specifications
Max
5.0
Operating pressure range (bar)
Min
0.5
The Filter cartridge requires a minimum of 2.0 bar
Maximum static pressure – 10.0 bar
Designed to comply with BS EN 200 for single
taps/ combination taps for water systems of
type 1 and 2 general technical specifications
and to be used within systems designed to
BS 6700.
BS 6700 recommends the temperature of stored
water should never exceed 65°C. A stored water
temperature of 60°C is considered sufficient to
meet all nominal requirements and will minimise
the build up of lime scale in hard water areas.