Before installation
Flush through the pipework to ensure
removal of debris. Turn off the mains
water supply and close any isolating
valves.
1. Fit push-fit connector
Place the ‘push-fit connector’ into the
hole in the basin top. Ensure the rubber
washer is fitted to the underside and the
side with ‘FRONT’ on is at the front.
2. Attach hot and cold connectors
Position the ‘back nut’ under the basin
(with rubber seal on top), ensuring the
locating pin fits into the hole in the back
nut.
Insert and
loosely
tighten the threaded
‘cold connector’ by turning the 6mm
hexagonal key clockwise. Once threading
has started you can let go of the back nut.
Before fully tightening the cold connector,
place the ‘hot connector’ into the push-fit
connector - ensure it fits fully through the
basin hole.
Note:
The hot connector has 2 flat edges
at the top to allow it to fit fully down and
close to the top of the cold connector.
Failure to do this may prevent the tap
fitting onto the connector.
Important:
The push-fit connector
must be fully tightened to the back nut
before attaching the flexible connecting
pipes.
Basin Mixer Tap - Installation
Push-fit
connector
Rubber
washer
6mm
hexagonal
key
Back nut with
rubber seal
Under
the
basin
Cold
connector
Hot
connector
Locating
pin