Document: SLSA-MIP-5-4-0-US
Date of Issue: 05/2016
Revision: -
15-20
1. Adjust the correct position of
holes for locking wire.
6. Pull the upper wire through the
hole in the other bolt. Hold the
wire end by pliers tighten it firm.
2. Pull the locking wire through
the hole in one bolt to be secured.
7. Hold the free end of wire by
hand, bend it around the bolt head
and along with the other end twist
it counterclockwise.
3. Hold the upper end of the wire
and wind it around the bolt head
and then by the other end of the
wire. Make sure that the wire is
properly tightened around the
head.
8. Hold the twisted end by pliers
and twist it tight.
4. Twist the wire to the hole in the
next bolt as tight as possible.
6. Pull the upper wire through the
hole in the other bolt. Hold the
wire end by pliers tighten it firm.
5. Tighten the wire and at the
same time continue its twisting
unless perfectly tightened. The
twisted wire can have
approximately from 3 to 4 threads
on the length of 10 mm (0,4 in).
7. Hold the free end of wire by
hand, bend it around the bolt head
and along with the other end twist
it counterclockwise.
Fig. 15-7
Procedure for securing the bolt joint with locking wire
Summary of Contents for S-LSA