Important safety information

These warnings are provided in the interests of safety. Ensure that you understand them all before
installing or using this appliance.Your safety is of paramount importance. If you are unsure about the
meaning of any of these warnings please contact the help line above.

Installation

This hood must be installed in accordance with the installation instructions and all measurements must
be adhered to.

A qualified electrician or competent person must undertake any installation work.

If the cooker hood is installed for use above a gas appliance the provision for ventilation must be in
accordance with the latest edition of the Gas Safety Codes of Practice, and the Gas Safety (Installation
& Use) Regulations, the Building Regulations issued by the Department of the Environment, the Building
Standards (Scotland) (Consolidated) Regulations issued by the Scottish Development Dept.

The fan motor of this cooker hood incorporates a cut -out device, which will operate if the cooker
hood is installed below the minimum height, or if the motor becomes overheated. If the cutout device
is activated, switch off the fan motor and allow the cooker hood to cool down.The cutout device will
reset itself when the fan motor has cooled significantly.

It is dangerous to alter the specifications or modify the product in any way.

When installed between adjoining wall cabinets, the wall cabinets must not overhang the hob/hotplate.

The following applies when ducting out 

If the room where the cooker hood is to be used contains a fossil fuel burning appliance such as a gas
or oil central heating boiler then its flue must be of the room sealed or balanced flue type.This hood is
not suitable for use in a room where any open flue appliance is in use. There shall be adequate
ventilation of the room when the range hood is used at the same time as appliances burning gas or
other fuels. Any local regulations concerning the discharge of exhaust air must be checked and fulfilled
prior to use of the hood.The ducting system for this appliance must not be connected to any existing
ventilation or flue system that is being used for any other purpose.

High level grills

Do not install this hood above a cooker with a high level grill.

Child safety

This appliance is designed to be operated by adults. Children should not be allowed to tamper with the
appliance.

During use

This product is for domestic use only.

Never leave frying pans unattended during use as overheated fats and oils may catch fire.

Do not flambé foods under the cooker hood 

Always turn on your hood every time you use your cooker.

Always use pans with lids.

Do not leave naked flames under the cooker hood.

1

Britannia Living,
Glen Dimplex Home Appliances,
Eastern Rise, Trentham Lakes,
Stoke-on-Trent
ST4  8WG

Britannia service & spares department
Tel: 0844 463 9705 (Option 1)
Email: service@britannialiving.co.uk

Summary of Contents for K240 90CM

Page 1: ...USER INSTRUCTIONS PRE PURCHASE INFORMATION INSTALLATION INSTRUCTIONS CHIMNEY HOOD MODELS K240 90CM and 100CM ...

Page 2: ... When installed between adjoining wall cabinets the wall cabinets must not overhang the hob hotplate The following applies when ducting out If the room where the cooker hood is to be used contains a fossil fuel burning appliance such as a gas or oil central heating boiler then its flue must be of the room sealed or balanced flue type This hood is not suitable for use in a room where any open flue ...

Page 3: ...erminations labelled SUPPLY are for the internal house wiring and the terminations labelled LOAD are for connection for the appliance WARNING THIS APPLIANCE MUST BE EARTHED Important The wires in this mains lead are coloured in accordance with the following code Green Yellow Earth Blue Neutral Brown Live As the colours of the wires in the mains lead of this appliance may not correspond with the co...

Page 4: ...ossible utilise rigid circular pipe or Mega duct ducting both types are available via your Britannia dealer Do not use expanding concertina type ducting as this is not smooth on the interior and can cause air flow restrictions Do not use ducting that has a smaller diameter than 150mm as this will reduce extraction rates and can increase noise levels Please note ducting kits and ducting components ...

Page 5: ...and wall plugs provided See A fig 4 For added security two additional fixing screws and rawl plugs must be fitted see B fig 4 5 Ensure the electric supply is turned off Connect hood supply cable to the power supply 6 Connect the ducting to the outlet spigot of the hood 7 Fit bracket W fig 5 to the wall 8 See fig 6 Place the telescopic flue assembly carefully onto the hood and extend the upper sect...

Page 6: ... to change the charcoal filters Changing the bulb First turn off the electricity supply to the hood Remove the retaining screw that holds the light diffuser in position Remove light diffuser Unscrew the light bulb and replace it only with Candle Halogen Lamp Ø35 E14 220 240Vac 28W or Incandescent Please note The information contained in this booklet is given in good faith and has been written for ...

Page 7: ...6 1 2 3 4 6 5 7 8 9 10 A A B A B C D E W min 65cm 50mm ...

Page 8: ...or domestic use only 4 Any service work will generally entail removal of the telescopic flue assembly to access key components including the motor If the flue assembly has been boxed in by means of a bridging shelf or any type of furniture this must be removed prior to our engineer s visit Before calling for service please check the following 1 Is there a power failure Turn on the appliance to che...