High level grills 

Do not install this hood above a cooker with a high level grill. 

Child safety 

This appliance is designed to be operated by adults. Children should not be allowed to tamper 
with the appliance. 

During use

 

This product is for domestic use only. 

Never leave frying pans unattended during use as overheated fats and oils may catch fire. 

Do not flambé food under the cooker hood. 

Always turn on your hood every time you use your cooker. 

Always use pans with lids. 

Do not leave naked flames under the cooker hood.  

Do not pull or twist the cable coming out of the appliance. 

Do not spray water directly on the appliance. 

Do not use any sharp objects. 

Always turn off the electricity supply before conducting any cleaning or maintenance. 

Maintenance and service 

This appliance can be a fire hazard if the grease filters and charcoal filters are not cleaned and 
replaced in accordance with instructions. 

Always insist on genuine spare parts. 

Under no circumstances should you attempt to repair the appliance yourself. Repairs carried out 
by inexperienced persons may cause injury or a more serious malfunction. 

In the event of service being required for your cooker hood please contact the service helpline. 

Summary of Contents for OMAGGIO

Page 1: ...1 of 11 USER INSTRUCTIONS INSTALLATION INSTRUCTIONS MODEL OMAGGIO CHIMNEY HOOD COD 3952041 ...

Page 2: ... cooker hood is installed below the minimum height or if the motor becomes overheated If the cut out device is activated switch off the fan motor and allow the cooker hood to cool down The cut out device will reset itself when the fan motor has cooled significantly It is dangerous to alter the specifications or modify the product in any way When installed between adjoining wall cabinets the wall c...

Page 3: ...under the cooker hood Do not pull or twist the cable coming out of the appliance Do not spray water directly on the appliance Do not use any sharp objects Always turn off the electricity supply before conducting any cleaning or maintenance Maintenance and service This appliance can be a fire hazard if the grease filters and charcoal filters are not cleaned and replaced in accordance with instructi...

Page 4: ... data according to Standard EN61591 Free air delivery Noise level according to Standard IEC60704 2 13 method Finish Stainless Steel Hardened Black Glass Size 900mm or 1000mm wide Controls Touch screen Air outlet 150mm diameter Illumination 5 x LEDs of 1 5 watts each Motor 1 x 345 watts 4 speeds Total wattage 353 watts Mains supply 230 volts 50 Hz Connection via a 13 amp fused spur outlet fused at ...

Page 5: ...bol or coloured green or green and yellow The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black The wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red Height above Hotplates For best performance we suggest that the hood is installed at a distance between 65cm to 75cm from t...

Page 6: ...oth on the interior and can cause air flow restrictions Do not use ducting that has a smaller diameter than 150mm as this will reduce extraction rates and can increase noise levels Please note ducting kits and ducting components are optional accessories and have to be ordered They are not supplied with the hood Maximum length of ducting run 4 metres with 1 x 90 degree bend 3 metres with 2 x 90 deg...

Page 7: ... 2 Telescopic chimney 3 Black glass If the hood is installed in filtering mode rather than ducted out the clean air will need to escape from the hood through the holes H as indicated on picture 6 Make sure that these holes H in picture 6 are free so that the recycled air can escape The hood is supplied with all the necessary fastenings for its installation which are suitable for most surfaces Plea...

Page 8: ... leds of all speed buttons will switch on as a reminder to clean the anti grease filters These can be cleaned by hand in hot soapy water or cleaned in a dishwasher To reset the timer keep the the button T4 pressed for 2 seconds If the timer is not reset then all leds will switch on again after the next time the hood is switched off Charcoal filters After 120 hours in operations the leds of all spe...

Page 9: ...ist tel 0870 863 8680 Option 3 Please note The information contained in this booklet is given in good faith and has been written for the use of hoods over Britannia domestic appliances Some of the information may not be applicable for use with other makes of appliances We reserve the right to alter any design or specification without notice ...

Page 10: ... repaired or modified by any other person than a member of our service division The guarantee does not cover misuse improper installation or any installation in commercial premises This product is for domestic use only Before calling for service please check the following 1 Is there a power failure Turn on the appliance to check the mains supply 2 Check that the fuse has not blown 3 Please note th...

Page 11: ...11 of 11 1 3 2 4 ...

Reviews: