When units are connected in series using DMX512 signal cable connect the units as shown
in the diagram below
Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin
connector of the first (MASTER) fixture.
Connect the end of the cable coming from the MASTER fixture which will have a (female) 3
pin connector to the input connector of the next fixture consisting of a (male) 3 pin
connector.
Then proceed to connect from the output as stated above to the input of the following fixture
and so on.
Set the first unit in the series to one of the STAND ALONE modes as described in section
2.2
All other units in the series should be set to <SLAVE> from the <operation> menu.
MASTER
SLAVE
SLAVE
When units are connected in series to a DMX512 controller and other DMX512 equipment,
connect the equipment as shown in the diagram below.
Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin
connector of the controller.
Connect the end of the cable coming from the controller which will have a (female) 3 pin
connector to the input connector of the next fixture consisting of a (male) 3 pin connector.
Then proceed to connect from the output as stated above to the input of the following fixture
and so on.
If over 32pcs fixtures connected ,the amplifier is needed.
DMX512
CONTROLLER
7
2 INSTALLATION
2008.7.31
2.4
SETTING UP (MASTER/SLAVE)
2.5
SETTING UP (DMX512 CONTROLLER)