background image

ENGLISH 

 

USER MANUAL 

 

 
BRITEQ

®

 

6/7 

BT-STROBE 1500 

Operation via optional CA-8 remote: 

  Connect the CA-8 remote to the 6,3mm jack connector (4) on 

the BT-Strobe 1500 (5) 

  Connect the BT-Strobe 1500 to the mains 

  Set DIP-switch 1 to ON 

  Now you can use the CA-8 remote to control the strobe. 

o

 

[STAND BY]  button (1)  :  used to switch ON and 
OFF the light output. 

o

 

[FUNCTION] button (2) : single flash when pushed 
once shortly, continuous  flashing when pushed 
continuously. 

o

 

[MODE] button (3) : There are 3 modes available. 

 

LED OFF : the BT-Strobe 1500 will show 
it’s patterns audio triggered 

 

LED BLINKING : press  the [FUNCTION] 
button briefly to change the flashing 
speed. Push the [FUNCTION] button 
longer to change the dimming mode. 

 

LED ON : press the [FUNCTION] button to 
choose the next pattern  which will be 
running audio triggered. 

 
MAINTENANCE 

  Make sure the area below the installation place is free from unwanted persons during servicing. 

  Switch off the unit, unplug the mains cable and wait until the unit has been cooled down. 

During inspection the following points should be checked: 

  All screws used for installing the device and any of its parts should be tightly fastened  and may not be 

corroded. 

  Housings, fixations and installations spots (ceiling, truss, suspensions) should be totally free from any 

deformation. 

  When an optical lens is visibly damaged due to cracks or deep scratches, it must be replaced. 

  The mains cables must be in impeccable condition and should be replaced immediately when even a 

small problem is detected. 

  In order to protect the device from overheat the cooling fans (if any) and ventilation openings should be 

cleaned monthly. 

  The interior of the device should be cleaned annually using a vacuum cleaner or air-jet. 

  The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to 

optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp, 
smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit’s optics. 

  Clean with a soft cloth using normal glass cleaning products. 

  Always dry the parts carefully. 

  Clean the external optics at least once every 30 days.  

  Clean the internal optics at least every 90 days. 

Attention: We strongly recommend internal cleaning to be carried out by qualified personnel! 
 

Summary of Contents for BT-STROBE 1500

Page 1: ......

Page 2: ......

Page 3: ...ontrollable on the housing Also works audio triggered when the optional CA 8 controller is used XLR 3pin DMX in outputs Automatic push to reset fuse BT STR4 a 4channel DMX remote controller with audio control is optionally available Compact and sturdy housing perfect for rental companies Very easy lamp replacement BEFORE USE Before you start using this unit please check if there s no transportatio...

Page 4: ...tallation should be carried out by qualified personal only according to the regulations for electrical and mechanical safety in your country Check that the available voltage is not higher than the one stated on the rear panel of the unit The power cord should always be in perfect condition Switch the unit immediately off when the power cord is squashed or damaged It must be replaced by the manufac...

Page 5: ...or connecting a second BT Strobe1500 or another DMX fixture 5 6 3mm Jack socket used for connecting JB Systems CA 8 controller order code 4192 6 Potentiometer for dimming 7 Potentiometer for speed control 8 DIP switches used for setting the DMX address see chapter HOW TO SETUP LAMP RE PLACEMENT Strobe tubes should be replaced by qualified technicians only Strobe tubes contain poisonous chemicals D...

Page 6: ... when installing the unit This secondary safety attachment should be installed in a way that no part of the installation can drop more than 20cm if the main attachment fails The device should be well fixed a free swinging mounting is dangerous and may not be considered Don t cover any ventilation openings as this may result in overheating The operator has to make sure that the safety relating and ...

Page 7: ...ins4 5 not used To prevent strange behavior of the light effects due to interferences you must use a 90Ω to 120Ω terminator at the end of the chain Never use Y splitter cables this simply won t work Make sure that all units are connected to the mains Each unit in the chain needs to have its proper starting address so it knows which commands from the controller it has to decode In the next section ...

Page 8: ...ll screws used for installing the device and any of its parts should be tightly fastened and may not be corroded Housings fixations and installations spots ceiling truss suspensions should be totally free from any deformation When an optical lens is visibly damaged due to cracks or deep scratches it must be replaced The mains cables must be in impeccable condition and should be replaced immediatel...

Page 9: ...ble 3x 2 5mm Fuse 15A automatic fuse DMX connections 3pin XLR male female DMX channels used 2 channels Lamp Xenon 1500W Size 458 x 147 x 116 mm Weight 3 58 kg Every information is subject to change without prior notice You can download the latest version of this user manual on our website www briteq lighting com ...

Page 10: ......

Page 11: ......

Page 12: ......

Reviews: