ENGLISH
OPERATION MANUAL
BRITEQ
®
9/73
BT-W19L10 ZOOM
Each unit in the chain must have its proper starting address so it knows which commands from the controller
it has to decode.
HOW TO SET THE RIGHT STARTING ADDRESS:
Refer to the previous chapter (DMX-512 address setting) to learn how to set the starting address on this unit.
The starting address of each unit is very important. Unfortunately it is impossible to tell you in this user
manual which starting addresses you have to use because this completely depends on the controller you will
use… So please refer to the user manual of your DMX-controller to find out which starting addresses you
must set.
DMX-CONFIGURATION:
The projector has 2 different DMX-modes, both 14channels. To make the difference we call the first one
14CH mode and the second one 14+CH mode.
14CH CHANNEL MODE:
CHANNEL VALUE
FUNCTION
1
000 - 255
Pan
2
000 - 255
Pan Fine (Least significant bit)
3
000 - 255
Tilt
4
000 - 255
Tilt Fine (Least significant bit)
5
000 - 255
Pan / Tilt Speed (000 = fast ~ 255 = slow)
6
Fixture control settings
000 - 009 No function
010 - 014 Reset all after 2 seconds
015 - 039 No function
040 - 044 Pan and tilt speed = NORM
045 - 049 Pan and tilt speed = FAST
050 - 054 Pan and tilt speed = SLOW
055 - 255 No function
7
000 - 255
Master Dimmer (0 to 100%)
8
Electronic shutter effect
000 - 019 Shutter closed
020 - 024 Shutter open
025 - 064
Strobe 1 (fast → slow)
065 - 069 Shutter open
070 - 084
Strobe 2: opening pulse (fast → slow)
085 - 089 Shutter open
090 - 104
Strobe 3: closing pulse (fast → slow)
105 - 109 Shutter open
110 - 124
Strobe 4: random strobe (fast → slow)
125 - 129 Shutter open
130 - 144
Strobe 5: random opening pulse (fast → slow)
145 - 149 Shutter open
150 - 164
Strobe 6: random closing pulse (fast → slow)
165 - 169 Shutter open
170 - 184
Strobe 7: burst pulse (fast → slow)
185 - 189 Shutter open
190 - 204
Strobe 8: random burst pulse (fast → slow)
205 - 209 Shutter open
210 - 224
Strobe 9: sine wave (fast → slow)