BRITEQ®
19
BTX-700BEAM
Lamp Too Hot Power Off
It appears when temperature is detected higher than 110
℃
. Check if the unit is properly
ventilated, or fans or temperature check board may is damaged.
Lamp Too Hot Low Power
It appears when detected temperature is over 105
℃
. the unit will run on a low power level.
Maintenance Fixture
It appears when the maintenance remaining time becomes 0S, please enter menu mode
and reset the time.
Lamp On Over 700 Hour
It appears when the lamp has been on over 700 hours, please turn off the lamp.
Memory Initial Fail
It appears when the memory IC is damaged.
CPU-B Error, CPU-C Error, CPU-D Error
They appear when board P.C or some wires are damaged.
Pan Reset Error, Pan Encode Error, Tilt Reset Error, Tilt Encode Error, Shutter Reset
Fail, Dimmer Reset Fail, Color Reset Fail, Cyan Reset Fail, Magenta Reset Fail, Yellow
Reset Fail, Gobo Reset Fail, R-Gobo Reset Fail, Effect Reset Fail, R-Effect Reset Fail,
and Frost Reset Fail
They may appear when turn on or reset the unit, for some parts such as board P.C are
damaged. Please contact the qualified maintenance.
7. Control By Universal DMX Controller
7.1 Connection