background image

ENGLISH

OPERATION MANUAL

BRITEQ

®

3/26

DMS-26

FUNCTIONS

(FRONT)

1. DMX OUTPUTS:

the DMS26 splitter section has 6 identical but completely isolated DMX-outputs: when

a problem occurs on one of the outputs (short circuits, overvoltage, …) the other outputs and the 2 inputs
will be protected and stay fully functional. All outputs have 3pin and 5pin XLR connectors to assure
maximum compatibility in a situations. (pin1 = ground/shield ; pin2 = data- ; pin3 = data+ ; pins 4/5 = not
used)

2. MENU BUTTON:

used to browse the main menu for the different options. Press this button 2 seconds to

save your choice permanently and return to normal user mode. See chapter “HOW TO USE” to learn
how to use the unit”

3. UP/DOWN BUTTONS:

used to change values or browse the different options in the sub menus.

4. ENTER BUTTON:

used to confirm your choice. However please note that you should press the MENU

button (2) for two seconds to save your choice permanently!

5. DISPLAY:

Multifunctional LED-display, shows the current working mode and helps selecting different

functions.

6. A/B INPUT:

shows which DMX-input (A and/or B) is routed to the 6 outputs.

FUNCTIONS

(REAR)

7. DMX INPUT A:

the DMS26 merger section has 2inputs. Input A (called the “main input”) is the used

when only 1 controller is attached. See chapter “HOW TO USE” to learn how to use the unit”

8. DMX INPUT B:

input B (called the “backup input”) is used to connect a second controller. See chapter

“HOW TO USE” to learn how to use the unit”

9. POWER SWITCH:

used to switch the unit on/off. The last settings are preserved.

10. MAINS INPUT:

with IEC socket and integrated fuse holder, connect the supplied mains cable here.

HOW TO USE

The main menu contains 4 sub menu’s, below we explain each option in detail and how you should use it:

Important:

to save your settings permanently, always press the MENU button (2) for 2 seconds!

MODE MENU

HTP OPTION

In HTP-mode (Highest Takes Precedence) two controllers will be connected to the inputs A and B (7/8). Both
controllers work simultaneously so both A/B INPUT (6) indicators are lit. The DMX-values of both controllers
are sent to the outputs but for corresponding channels, the channel with the highest value will be routed to
the outputs.
Example:
Controller A: ch1=102 + ch2=88 + ch3=246 + ch4=000
Controller B: ch1=105 + ch2=186 + ch3=101 + ch4=005

Outputs: ch1=105 + ch2=186 + ch3=246 + ch4=005

ENGLISH

OPERATION MANUAL

BRITEQ

®

4/26

DMS-26

MODE MENU

BACKUP OPTION

In BACKUP-mode (“b-uP” on the display) two controllers will be connected to the inputs A and B (7/8). The
controller connected to input A is the main controller that will be routed to the outputs. If, for any reason,
controller A fails, controller B (the backup controller) takes over immediately. On the A/B INPUT LEDs (6)
you can always check which controller is in command!
When both controllers fail, you can decide how the
outputs should react: see “NO INPUT option” below.

MODE MENU

MERGER OPTION

Normally you can’t make 2 DMX-controllers work
together on 1 DMX-line: both controllers send out the
same channels and signals would crash. This is the
solution: in MERGER-mode (“MErg” + start address
controller B alternate on the display) you can
connect two controllers to the inputs A and B (7/8)
and make them work together on 1 single DMX-
cable. The controller connected to input A (7) is the
first controller, starting from DMX address 001. For
the controller connected to input B (8) you can freely
set the DMX start address (see “Addr option” below)
Example:
Controller A is a 24channel DMX-controller for
Theater lighting.
Controller B is 192channel DMX-controller for
moving heads/scanners.

Both controllers can work together on 1 DMX-
cable, just set the start address for controller B
to 025 and add 25 to the original DMX-channels
of the scanner controller: original DMX-address
001 becomes 025, original DMX-address 130
becomes 155 (130+025)

ADDR OPTION

Will only be used in MERGER mode to set the start address of the controller connected to input B (8). For
more information on the merger mode, see previous option.

Hint:

If you have a controller with 24ch connected to input A and you only want to use the 12 first channels,

than you can set the start address for controller B to 013. This will save channels…

TIMING OPTION

Modern “high speed” DMX-controllers send a full 512ch package with a refresh rate of max. 44Hz (or 23ms).
Most common the refresh rate is set to 40Hz (25ms). Some low cost Chinese DMX-equipment is not able to
work at these high refresh rates, as a result data is lost and all kinds of unpredictable behavior occurs. To
solve this problem the DMS-26 is able to adapt the refresh rate in a range from fast “23ms(44Hz)” to slow
“45ms (22Hz)” for increased compatibility between DMX-units.
So if you encounter timing problems, try to set the timing to a higher value (slower refresh). In most cases
30ms will be a good value.

“NO INPUT” OPTION

When no DMX is detected on both inputs A and B (7/8), you can choose how the outputs should react. Three
options are available:

Null:

no DMX signal on the outputs (some DMX-equipment will start working in standalone mode)

Hold:

keep the last DMX values on the outputs (avoids a general “blackout” on stage)

Clear:

set the DMX values on all outputs to zero (all projectors will go to “blackout”)

Just choose the behavior that suits best for the job.

Summary of Contents for dms 26

Page 1: ... a t Hofveld 2 B1702 Groot Bijgaarden Belgium Reproduction or publication of the content in any manner without express permission of the publisher is prohibited Operation Manual Mode d emploi Gebruiksaanwijzing Bedienungsanleitung Manual de instrucciones EN FR NL DE ES ...

Page 2: ...t toestel en de gebruikte batterijen op een milieuvriendelijke manier conform de in uw land geldende voorschriften DU ENTSORGUNG DES GERÄTS Entsorgen Sie das Gerät und die Batterien auf umweltfreundliche Art und Weise gemäß den Vorschriften Ihres Landes ES DESHACERSE DEL APARATO Reciclar el aparato y pilas usadas de forma ecologica conforme a las disposiciones legales de su pais PT COMO DESFAZER S...

Page 3: ... use only Don t place metal objects or spill liquid inside the unit No objects filled with liquids such as vases shall be placed on this appliance Electric shock or malfunction may result If a foreign object enters the unit immediately disconnect the mains power No naked flame sources such as lighted candles should be placed on the appliance Don t cover any ventilation openings as this may result ...

Page 4: ...main controller that will be routed to the outputs If for any reason controller A fails controller B the backup controller takes over immediately On the A B INPUT LEDs 6 you can always check which controller is in command When both controllers fail you can decide how the outputs should react see NO INPUT option below MODE MENU MERGER OPTION Normally you can t make 2 DMX controllers work together o...

Page 5: ...rend le relais immédiatement Merger les signaux DMX en provenance de deux contrôleurs différents peuvent être combinés et envoyés via un même câble on peut choisir l adresse de départ du second contrôleur par exemple combiner un CMX 24 et et un Scanmaster sur un même câble La fonction splitter quant à elle distribue les signaux DMX présents aux entrées vers les six sorties de manière identique sor...

Page 6: ...ur en garde contre la présence de haute tension sans isolation dans l appareil ce qui peut causer un risque d électrocution Un point d exclamation dans un triangle prévient de la présence d instructions relatives au fonctionnement et à la maintenance se trouvant dans le manuel fourni avec l appareil Ce symbole signifie uniquement pour usage à l intérieur Ce symbole signifie Lire le mode d emploi C...

Page 7: ...Le contrôleur connecté à l entrée A 7 est le premier contrôleur et il a l adresse de départ 001 Quant au contrôleur connecté à l entrée B 8 vous pouvez lui donner une adresse DMX à votre guise voir ci dessous Option ADDR Exemple Le contrôleur A est un contrôleur DMX à 24 canaux destiné à gérer l éclairage d un théâtre Le contrôleur B est un contrôleur DMX à 192 canaux qui pilote des moving heads e...

Page 8: ...weede controller instellen De splitter functie verdeelt de DMX signalen van de ingangen over 6 identieke uitgangen welke allemaal 100 van elkaar geïsoleerd zijn indien er zich een probleem voordoet op 1 van de uitgangen dan zal dit de andere uitgangen niet beïnvloeden De snelheid van de DMX uitgangen kan ingesteld worden 23ms tot 45ms dit verbetert de compatibiliteit wanneer trage DMX toestellen a...

Page 9: ... zich geen onderdelen in het toestel die u zelf kan herstellen Laat de herstellingen enkel uitvoeren door een bevoegde technicus De bliksempijl die zich in een gelijkbenige driehoek bevindt is bedoeld om u te wijzen op het gebruik of de aanwezigheid van niet geïsoleerde onderdelen met een gevaarlijke spanning in het toestel die voldoende kracht heeft om een risico van elektrocutie in te houden Het...

Page 10: ...t startadres voor controller B op 025 en voeg 24 toe aan de originele DMX kanalen van de scanner controller origineel DMX adres 001 wordt 025 origineel DMX adres 130 wordt 154 130 024 ADDR OPTIE Zal enkel gebruikt worden in MERGER modus om het startadres in te stellen van de controller die aangesloten is op ingang B 8 Zie vorig hoofdstuk voor meer informatie over de merger modus Hint als u op inga...

Page 11: ...en sie das Gerät bitte nach dem Transport in einer warmen Umgebung einige Zeit zum Temperaturausgleich stehen Kondensation kann zu Leistungsverlust des Gerätes oder gar Beschädigung führen Gerät nicht im Freien und in feuchten Räumen und Umgebungen verwenden Keine Metallgegenstände oder Flüssigkeiten ins Innere des Geräts gelangen lassen Keine mit Flüssigkeit gefüllten Gegenstände z B Vasen auf da...

Page 12: ...6 K4 000 Controller B K1 105 K2 186 K3 101 K4 005 Ausgänge K1 105 K2 186 K3 246 K4 005 MODUS MENU BACKUP OPTION Im BACKUP Modus b uP auf dem Display sind zwei Controller an den Eingängen A und B 7 8 angeschlossen Der am Eingang A angeschlossene Controller ist der Hauptcontroller der zu den Ausgängen geleitet wird Sollte der Controller A aus irgendeinem Grund ausfallen übernimmt der Controller B de...

Page 13: ...trada A falla la señal DMX en la entrada B toma el lugar inmediatamente Merger Fusión las señales DMX provenientes de 2 diferentes controladores se pueden combinar y enviar por 1 cable puede seleccionar la dirección de inicio del segundo controlador La función de división distribuye la s señal es DMX desde la s entrada s por 6 salidas idénticas que están 100 aisladas entre si Los problemas que ocu...

Page 14: ...a de flecha dentro de un triángulo equilátero se emplea para alertar sobre el uso o presencia de voltaje peligroso no aislado dentro de la carcasa del producto con la magnitud suficiente para constituir un riesgo de descarga eléctrica El signo de exclamación dentro de un triángulo equilátero se emplea para alertar al usuario de la presencia de instrucciones de funcionamiento y mantenimiento servic...

Page 15: ...s DMX originales del controlador del escáner la dirección DMX original 001 pasa a ser 025 la dirección DMX original 130 pasa a ser 154 130 024 OPCIÓN ADDR Se utilizará sólo en la modalidad FUSIÓN para ajustar la dirección de inicio del controlador conectado a la entrada B 8 Para obtener más información sobre la modalidad fusión vea la opción anterior Consejo Si tiene usted un controlador con 24 ca...