background image

 

5- 

3.2 Main Function   

To select any of the given functions, press the 

MENU

 button up to when the required one is 

showing on the display. Select the function by 

ENTER

 button and the display will blink. Use 

DOWN

  and 

UP

  button  to  change  the  mode.  Once  the  required  mode  has  been  selected, 

Press 

ENTER

  button  to  store.  Back  to  the  main  functions  without  any  change  press  the

 

MENU

 button or wait for 1 minute.   

Hold 

MENU 

button to exit menu mode, the 

unit  will  run  the  built-in  program  you 

selected At this time you can press 

UP

 and 

DOWN

  button  to  change  show,  the  new 

show will effect immediately. If you change 

to  show  1-8  or  Auto  Fade,  you  can  press 

ENTER

  button  to  choose  speed.  The  unit 

will run in the speed selected or it will run to 

the music. 

The  main  functions  are  shown  on  the 

drawing: 

 

DMX Address 

Press  the 

MENU

  button  up  to  when  the 

DMX  Address  is  showing  on  the  display. 

Press 

ENTER

  button  and  the  display  will 

blink. Use 

DOWN

 and 

UP

 button to change 

the  DMX512  address.  Once  the  address 

has  been  selected,  press  the 

ENTER

 

button to store. Back to the main functions 

without  any  change  press  the

  MENU

 

button  (or  wait  for  1  minute  to  exit  menu 

mode).

 

Channel Mode 

Press  the 

MENU

  button  up  to  when  the 

Channel  Mode  is  showing  on  the  display. 

Press 

ENTER

  button  and  the  display  will 

blink. Use 

DOWN

 and 

UP

 button to select 

Summary of Contents for STAGE PAINTER 12

Page 1: ...STAGE PAINTER 12 Preliminary User Guide Official version will follow soon on WWW BRITEQ LIGHTING COM ...

Page 2: ...1 TABLE OF CONTENTS 1 Safety Instruction 2 Technical Specification 3 How To Set The Unit 4 How To Control The Unit 5 Troubleshooting 6 Fixture Cleaning ...

Page 3: ...ng as it is fire hazard Use safety cable when fixes this unit Maximum ambient temperature is TA 40 Don t operate it where the temperature is higher than this In the event of serious operating problem stop using the unit immediately Never try to repair the unit by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assis...

Page 4: ...are attaching the unit is secure and is able to support a 10 times weight of the unit 2 Technical Specification 3 6 9 12 15 channels switchable Automatically switching between music trig and auto mode Great built in programs under Master Slave mode trigged by music Individual control of each LED cluster Sound sensitivity adjustable via the menu Auto fading show with 3 different speeds Specially de...

Page 5: ... go forward in the selected functions ENTER To confirm the selected functions Microphone Receive the sound to control the unit Only for remote control By connect to the 1 4 microphone jack to control the unit for Stand by Function and Mode function Mains input Connect to supply mains power Mains output Connect to supply mains power for other units Fuse For over current protection DMX input output ...

Page 6: ...w show will effect immediately If you change to show 1 8 or Auto Fade you can press ENTER button to choose speed The unit will run in the speed selected or it will run to the music The main functions are shown on the drawing DMX Address Press the MENU button up to when the DMX Address is showing on the display Press ENTER button and the display will blink Use DOWN and UP button to change the DMX51...

Page 7: ...tting Color 1 or or Color 32 once selected press MENU button to store If you choose Maun press the ENTER button to confirm you can press DOWN and UP button to select Red or Green or Blue press ENTER button to confirm and press DOWN and UP button to adjust the value then press ENTER button to store Back to the main functions without any change press the MENU button or wait for 8 seconds Slave Mode ...

Page 8: ...ing ENTER button and the display will show Test and the unit will run self test by built in program To go back to the functions press the MENU button Manual Test Press the MENU button up to when the Manual Test is showing on the display Press ENTER button and Red 1 will blink use UP and DOWN button to choose Green 1 or Blue 1 or Red2 or or Blue 4 or Dimmer or Strobe press ENTER button to enter the...

Page 9: ... button Firmware Version Press the MENU button up to when the Firmware Version is blinking on the display Pressing ENTER button and the display will show the version of software of the unit To go back to the functions press the MENU button 4 How To Control The Unit You can operate the unit in three ways 1 By master slave built in preprogram function 2 By easy controller 3 By universal DMX controll...

Page 10: ...d the display will blink Use DOWN and UP button to change the DMX512 address Once the address has been selected press and keep ENTER button to store To go back to the functions without any change press the MENU button or wait for 1 minute to exit menu mode Please refer to the following diagram to address your DMX512 channel for the first 4 units Channel Mode Unit 1 Unit 2 Unit 3 Unit 4 3 channels ...

Page 11: ...10 4 4 DMX 512 Configuration Front View DMX Configuration ...

Page 12: ...11 ...

Page 13: ...12 ...

Page 14: ...ery high speed signal Inadequate or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system 4 The DMX output and input connectors are pass through to maintain the DMX circuit when power is disconnected to the unit 5 Each lighting unit needs to have an address set to receive the data sent by the controller The address number is between 0 511 usua...

Page 15: ...eck the address settings and DMX polarity 3 If you have intermittent DMX signal problems check the pins on connectors or on PCB of the unit or the previous one 4 Try to use another DMX controller 5 Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit C Some units don t respond to the easy controller 1 You may have a...

Page 16: ...ully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days EC Declaration of Conformity We declare that our products lighting equipments comply with the following specification and bears CE mark in accordance with the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55103 1 199601 2 EN55103 2 1996 EN61000 3 2 2000 A2 2005 EN61...