background image

  

// 

14.0 SERVICING

  

This appliance is supplied with a BS1363 3-pin plug 

fitted with a 13 Amp fuse. Should the fuse require 

replacing, it must be replaced with a fuse rated at 

13 Amp and approved to BS1362. In the event of 

the mains plug being removed/replaced for any 

reason, please note :

The wires in the mains lead are coloured in 

accordance with the following code:

Blue

Neutral

Brown

Live

Green/Yellow

Earth

As the colours of the wires in the mains lead of 

this appliance may not correspond with the colour 

markings identifying the terminals in your plug, 

proceed as follows.

The blue wire must be connected to the terminal 

marked with an N or coloured black. The brown 

wire must be connected to the terminal marked 

with an L or coloured red. The green/yellow wire 

must be connected to the earth terminal which is 

marked with an E or with the earth symbol.

NOTE:

 If a moulded plug is fitted and has to be 

removed take great care in disposing of the plug 

and severed cable, it must be destroyed to prevent 

engaging into a socket. Refer to Section 3.0, 

Appliance Data for fuse specification. Excluding 

fuses, use only genuine manufacturers spare parts 

available from your supplier. 

There are no internal 

user serviceable parts.

My Electric Stive Fire...

Remedy 

is not switching on

Ensure mains switch is on. Replace the fuse in the plug.

is not emitting any heat

The fire is fitted with an energy saving thermostat. If the 

temperature in the room is higher than the temperature 

selected on the fire, then the thermostat will stop the heater 

from turning on. For example, if the room temperature is 22°C 

or above and the fires heater is set at 22°C, then the heater 

will not be required until the room temperature drops below 

22°C. If this is the case select a higher temperature setting 

than the room’s temperature and the heater will begin to 

operate. The safety cut-out may have been operated. Switch 

the appliance off, leave for two minutes then switch back on. 

shuts off after a period of time

Check that the temperature is not set onto the lower settings. 

If the room is warm enough the thermostat will stop the fire 

switching the heat on.
Check that the chimney/flue is blocked off.
Check that the window detection sensor has not activated.

// 

12.0 TROUBLESHOOTING GUIDE

 

//

 

WARNING:

Never connect live or neutral wires to the earth terminal of the plug.

// 

13.0 SPARES

Refer to Section 3.0 Appliance Data for lamp and 

fuse specification. Excluding lamps and fuses, use 

only genuine manufacturers spare parts available 

from your supplier.

// 

15

// 

16

© 2019 British Fires

Summary of Contents for ASHURST

Page 1: ... 2019 British Fires INSTALLATION USER INSTRUCTIONS ASHURST ELECTRIC LED SQUARE STOVE INSTALLATION USER INSTRUCTIONS ASHURST ELECTRIC LED BARREL STOVE ...

Page 2: ...ce CAUTION Some parts of this product can become very hot and cause burns Particular attention has to be given where children and vulnerable people are present If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard The heater must not be located immediately below a socket outlet DO NOT use this heater in the...

Page 3: ...kg 30kg Dimensions H951 x W420 x D420mm Supply Voltage and Rating Power 220 240V AC 50Hz 1700 2000W Fuse Rating 13 Amp Heating Elements 2000W Lighting LED Location Indoor use only Supply plug cord BS1363 1 7 metres long Item Symbol Value Unit Item Unit Item Unit Heat Output Types of heat input for electric storage local space heaters only Other control options Nominal heat output Pnom 2 0 KW Manua...

Page 4: ... location DO NOT recess any part of the appliance into the wall or run the supply cable under carpets DO NOT site in a position where curtains or drapes could cover the appliance or other soft materials could cover e g below a coat rack DO NOT site behind an opening door where mechanical impact damage could occur DO NOT site where the supply cable would become a trip hazard DO NOT sit stand or for...

Page 5: ...o n s o n l y F o r p l a s t e r b o a r d w a l l s u s e a n a l t e r n a t i v e f i x i n g m e t h o d s h o w n i n s e c t i o n 8 0 I n s e r t t h e w a l l a n c h o r s i n t o t h e h o l e s i n t h e w a l l u s i n g a h a m m e r 8 3 I INSTALLATION FREESTANDING FLUE PIPE CONTINUED 4 Place the Flue Pipe back into its final position and secure the Flue Pipe to the wall by fastening...

Page 6: ...t time you power up the fireplace the unit will turn on with the same settings TEMPERATURE SETTING Adjust the temperature to the desired setting 15 to 30 C Range using the buttons NOTE The set temperature must be above the room temperature for the heating function to operate HEATER OPERATION Press the Heater button to select Full Heat setting 2000W and H2 with the red flame symbol will be displaye...

Page 7: ... week and the timer can be set using the following procedure 1 Press the Power button to turn the unit on 2 Press hold the Timer Mode M button for two seconds to enter the timer settings The settings for the 1st ON OFF period M1 for Monday will be shown with the 1st ON time hour setting flashing 3 Adjust the hour setting using the buttons and press the Time Setting button to select the minute sett...

Page 8: ...ce may cutout for a further period of time If the sequence has been followed correctly and the appliance still fails to function check the fuse in the wall outlet If this is not the cause call an electrician or maintenance engineer ALWAYS disconnect the stove from the mains supply before undertaking any maintenance of the appliance For general cleaning use a soft clean duster never use harsh abras...

Page 9: ...plier There are no internal user serviceable parts My Electric Stive Fire Remedy is not switching on Ensure mains switch is on Replace the fuse in the plug is not emitting any heat The fire is fitted with an energy saving thermostat If the temperature in the room is higher than the temperature selected on the fire then the thermostat will stop the heater from turning on For example if the room tem...

Page 10: ...ed to be faulty or defective in manufacture will be repaired or replaced free of material and labour charges providing that we have authorised or carried out the repair or replacement We will not accept or reimburse the costs of any third party who undertakes any work carried on the product or fits parts unless we have approved such work in advance of it being carried out The guarantee period will...

Page 11: ...tish Fires You are not permitted to copy or adapt any of the content without the prior written permission of British Fires 2019 British Fires All instructions must be handed to the user for safekeeping Revision A 10 19 British Fires Christchurch Dorset BH23 2BT Tel 0808 169 9911 www britishfires com Email sales britishfires com Models covered by these instructions Ashurst LED Electric Stove HS9338...

Reviews: