Fault Finding

Fault                                     

Pump doesn’t run

Cause

                                      

Remedy

A) Blown fuse                           Replace fuse

B) Inadequately connected         Check electrical connection
     power supply 

C) Pump is defective                  Replace pump

D) Impurity in the system          Disconnect and clean 

E)  Bearing has blocked              Run at high speed for a 
     pump from running               for a short period or loosen
                                                the rotor at the end of the 
                                                shaft with a screwdriver

                      

Before starting any work on the pump please ensure the 
electricity supply is turned off and cannot be accidentally 
switched back on at any time

Summary of Contents for UPSA Domestic

Page 1: ...Installation Operating Instructions Please read these instructions carefully before installation ...

Page 2: ...Contents General Information 3 Pump Liquid Operating Conditions 4 Pump Diagram 5 Installation 6 7 Fault Finding 8 9 Maintenance Repair 10 11 Guarantee Registration 12 ...

Page 3: ...circulator which is perfectly suited to operate in Single zone heating systems Multi zone heating systems Underfloor heating systems The pump incorporates 3 constant speeds enabling you to set it based on system demand It has a connection size of 1 a maximum head of 6 meters and a port to port distance of 130mm making it perfect for light commercial applications ...

Page 4: ...heir internal components The liquids used must not contain any solid particles fibres or mineral oil Liquids running through circulation pumps used on heating systems must comply with the accepted standards of quality especially in domestic applications Liquids that do not comply will void the warranty offered with the circulation pump ...

Page 5: ...Pump Diagram Bleed Screw ...

Page 6: ...Installation Attention Ensure the pump is installed with the motor shaft in the horizontal position ...

Page 7: ...Attention Fit the two gaskets when the pump is mounted correctly between the flow and return pipes ...

Page 8: ...fective Replace pump D Impurity in the system Disconnect and clean E Bearing has blocked Run at high speed for a pump from running for a short period or loosen the rotor at the end of the shaft with a screwdriver Before starting any work on the pump please ensure the electricity supply is turned off and cannot be accidentally switched back on at any time ...

Page 9: ...Remedy A Air in the system Vent the system B Pump speed too high Reduce the speed Fault Noise in the pump Cause Remedy A Air in the pump Let the pump run it vents itself over time B Inlet pressure too high Increase the inlet pressure ...

Page 10: ...Maintenance Repair Attention Ensure the pump is fully vented before first time operation ...

Page 11: ...Attention The pump liquid may be scalding hot and under high pressure Before removing head screws the system either requires draining or the pump needs to be isolated ...

Page 12: ...purchase The pump is covered for a free of charge replacement should malfunction occur within the first 3 years from the date of sale To register please email the following details to guarantees brittherm co uk Date of purchase Address where pump is fitted Name of supplier Supplier invoice number Please retain your purchase invoice as it may be required in the event of a guarantee claim To make a ...

Reviews: