Service Maintenance
End of Season Maintenance
Turn OFF the water supply to the unit at the isolating stop tap.
NOTE
* Do not turn OFF the power supply to the Cooler for longer than is necessary
for carrying out maintenance.
* If the power supply is turned OFF, the Networker will lose its Time/Day
settings.
* If power must be switched OFF, first make sure the ServoSeal is completely
closed.
Dismantling the Water Distribution System
Remove the 4 plastic thumb screws from the roof.
Remove the front and back pad frames, lift the roof to release the frames from the
cabinet.
Disconnect the 19mm clear water feed tube to the roof assembly at the base
connection.
Remove the roof assembly.
Release the 4 plastic thumb screw bushes from the inner distribution tray of the roof
assembly. Push the bushes out of the distribution tray.
Separate the roof outer and the inner distribution tray.
Clean the components and reassemble.