Although we are able to produce a material spreading chart, it is by no means accurate for
every fertiliser, top dressing or seed that is likely to be spread by this machine. Differing
material density particle size and moisture content all affect the flow rate and spread pattern
that the machine provides.
=
Any material used with this machine must be dry, free flowing and stored in dry conditions to
maintain its quality.
=
To accurately ascertain the spread rate pattern and quality the machine should be calibrated by
the use of test trays.
ADJUSTMENT OF SPREAD PATTERN
=
In order to achieve a balanced spread pattern with even material application the angle of the
spreader vanes must be adjusted, via the means of 4 adjustment position holes for each vane.
=
The holes number 1 to 4 for each vane. All vanes must be placed in the same number hole.
=
To move the spread pattern more to the left (when viewing spreader from the rear of the
operating vehicle) place all the holes in hole position 1-2. To move the pattern more to the right
move the vanes to hole position 3 or 4.
=
When viewing spread pattern take care to ensure all persons and animals are away from the
possible maximum spread pattern. Always wear safety goggles.