DiViNe Route/Repeat 66/33
13
rev. 1.0
Word Clock
Devices with Optocore/SANE modules are equipped with an internal, high quality, low jitter clock as well as Word
Clock inputs and outputs. Any device on the network can act as the master of the network and pass Word Clock
to networked Optocore/SANE devices.
The internal/networked Word Clock is available at the Word Clock output connector of each device on the network
to synchronize non-networked devices.
In standalone network configurations external synchronization is not required.
The Word Clock input termination can be switched on using the OPTOCORE CONTROL software’s Local
Settings. No additional external termination is required to avoid cable reflections.
Optocore Transmission Delay
The Optocore system delay, including the matrix, is a fixed 41,6 µs @ 48 kHz for all channels. The additional
transport delay per Optocore unit on the network (<200 ns) is insignificant in comparison. Overall system delay is
dependent on the converters used and the length of network cables in the system. Assuming ‘normal’ cable
lengths of <700 m per link, the additional delay is considered marginal.
The transmission delay is constant between any points in the network.
Power Supply
The device is optionally equipped with two power inputs and power supplies. If the primary power supply were to
fail, due to disruption of the power source or in the case of a power supply malfunction, the device will
automatically switch over to the redundant power supply. In order to make the power supply to the device
redundant, both power inputs must be connected to the mains supply, if possible to different phases, circuits, or
even better, having one of the power supplies connected to an uninterrupted power supply (UPS).
The power supplies operate with mains voltage of 100 ... 240 V and frequency of 50 … 60 Hz. The device can be
used throughout the world without any modifications or transformers.
Please note:
The switched-mode power supplies operate at very high voltages! Coming into contact with the power
supplies can lead to considerable electric shock, which may result in death! To prevent electric shocks,
do not remove any covers of the device!
Control
A Route/Repeat 66/33 does not require software to be fully operable. Each unit is configured by the manufacturer
according to the requirements of the customer. No further configuration is necessary.
Signal routing can be to be preconfigured with automatic discovery and routing or controlled manually using a 3
rd
party integration control platform such as VSM by the company LSB.
Auxiliary port (RS485/422) settings and the device ID can be configured by the user using the Optocore Control
Software with a PC connected to the RS232, LAN or USB ports of the device.
For further information please contact the BroaMan technical support team.