background image

 

 

DiViNe Route/Repeat 66/33

 

13 

rev. 1.0 

  

Word Clock 

Devices with Optocore/SANE modules are equipped with an internal, high quality, low jitter clock as well as Word 
Clock inputs and outputs. Any device on the network can act as the master of the network and pass Word Clock 
to networked Optocore/SANE devices.  
The internal/networked Word Clock is available at the Word Clock output connector of each device on the network 
to synchronize non-networked devices.  
In standalone network configurations external synchronization is not required. 
The  Word  Clock  input  termination  can  be  switched  on  using  the  OPTOCORE  CONTROL  software’s  Local 
Settings. No additional external termination is required to avoid cable reflections.  

 

Optocore Transmission Delay 

The  Optocore  system  delay,  including  the  matrix,  is  a  fixed  41,6 µs  @  48  kHz  for  all  channels.  The  additional 
transport delay per Optocore unit on the network (<200 ns) is insignificant in comparison. Overall system delay is 
dependent  on  the  converters  used  and  the  length  of  network  cables  in  the  system.  Assuming  ‘normal’  cable 
lengths of <700 m per link, the additional delay is considered marginal. 
The transmission delay is constant between any points in the network. 

 

Power Supply 

The device is optionally equipped with two power inputs and power supplies. If the primary power supply were to 
fail,  due  to  disruption  of  the  power  source  or  in  the  case  of  a  power  supply  malfunction,  the  device  will 
automatically  switch  over  to  the  redundant  power  supply.  In  order  to  make  the  power  supply  to  the  device 
redundant, both power inputs must be connected to the mains supply, if possible to different phases, circuits, or 
even better, having one of the power supplies connected to an uninterrupted power supply (UPS). 

The power supplies operate with mains voltage of 100 ... 240 V and frequency of 50 … 60 Hz. The device can be 
used throughout the world without any modifications or transformers. 

Please note: 
The  switched-mode  power  supplies  operate  at  very  high  voltages!  Coming  into  contact  with  the  power 
supplies can lead to considerable electric shock, which may result in death! To prevent electric shocks, 
do not remove any covers of the device! 

 

Control 

A Route/Repeat 66/33 does not require software to be fully operable. Each unit is configured by the manufacturer 
according to the requirements of the customer. No further configuration is necessary.  
Signal routing can be to be preconfigured with automatic discovery and routing or controlled manually using a 3

rd

 

party integration control platform such as VSM by the company LSB.  
Auxiliary port (RS485/422) settings and the device ID can be configured by the user using the Optocore Control 
Software with a PC connected to the RS232, LAN or USB ports of the device.  
For further information please contact the BroaMan technical support team. 

 

Summary of Contents for DiViNe Repeat33

Page 1: ...Network Operating Manual Rev 1 0 Operating Manual for DiViNe Route Repeat 66 33 Digital Video Network device with Optocore and SANE Copyright 2011 All rights reserved BROAMAN GmbH Lohenstr 8 82166 Munich Gräfelfing Germany ...

Page 2: ...any other way or form Pay special attention to the plugs and sockets of the device Do not place this device on an unstable table tripod cart etc The device may fall causing serious damage to the device The device can be disconnected from the power supply by unplugging the power cord The power cords must be freely accessible at all times The device should be disconnected during lightning storms or ...

Page 3: ...or audio video and audio visual and entertainment lighting control apparatus for professional use E1 Residental E2 Commercial and light industrial E3 Urban outdoors E4 Controlled EMC environment e g broadcast and TV studio E5 Heavy industry The product is intended for use in moderate climates Ventilation Do not block or cover any ventilation openings Install the device in accordance with the opera...

Page 4: ...e mains socket External objects and or liquids Never insert objects of any kind into the device through openings in the device chassis The objects may come into contact with dangerous voltages or create short circuits that can result in a fire or electric shock Never spill liquid of any kind on the device Cables and Accessories Only use attachments that are specified by the manufacturer of the dev...

Page 5: ...tandard for audio video audio visual and entertainment lighting control apparatus for professional use EN 55103 1 Emission EN 55103 2 Immunity The authorised declaration and compatibility certification lies with the manufacturer and can be viewed on request Responsible as manufacturer is BROAMAN GmbH Lohenstr 8 82166 Munich Gräfelfing Germany represented by Marc Brunke Managing Director N B The aw...

Page 6: ...ltiplexers 12 Optocore Fibre Optic Connection 12 SANE Ports 12 RS485 GPIO Auxiliary Ports 12 Word Clock 13 Optocore Transmission Delay 13 Power Supply 13 Control 13 Connectors and Cables 14 SD HD 3G SDI Ports 14 Optical Connections 14 SANE Ports 14 Auxiliary Ports R485 GPIO 14 RS232 Connection 14 Connector Hood Quality 14 USB Connection 15 LAN Connection 15 Word Clock Connection 15 Power Connectio...

Page 7: ... required 2RU frames can be equipped with up to 24 BNC ports for SD HD 3G SDI video 20 duplex LC fibre ports and up to 36 simplex LC fibre ports 1RU frames can be equipped with up to 10 BNC ports for SD HD 3G SDI video and up to 8 simplex LC fibre ports SD HD 3G SDI I O options include input with adaptive EQ input with reclocker output output with reclocker and a switchable I O Route Repeat 66 33 ...

Page 8: ...eo router Route66 66 channel video router ACT LED Signal indication on channels 1 40 LED ON Signal is present LED OFF No signal is present AUDIO LINK SL1 Communication is established via SANE 1 rear panel SL2 Communication is established via SANE 2 rear panel OL1 Communication is established via Optocore LINK 1 rear panel OL2 Communication is established via Optocore LINK 2 rear panel Master LED I...

Page 9: ...LED Green Indicates data activity RS232 connector RS232 D Sub 9 connection for remote control and firmware updates via PC LAN LINK S1 Ethernet communication is established via SANE 1 rear panel S2 Ethernet communication is established via SANE 2 rear panel UP There is another device with an enabled Ethernet port on the network L1 Ethernet communication is established via LAN 1 rear panel L2 Ethern...

Page 10: ...eclocker Blackburst output derived from a specified video source within the system POWER 1 Mains input for power supply 1 100 240 V POWER 2 Mains input for power supply 2 100 240 V Fibre SFP ports 1 20 Can be populated with up to 20 user changeable SFP fibre ports with TX and RX Each port can be configured by the manufacturer as Simplex transmitter receiver for video Duplex transceiver for use wit...

Page 11: ...nput for power supply 2 100 240 V Fibre ports 1 8 Can be populated with up to 8 fibre ports with TX and or RX Each port can be configured by the manufacturer as Simplex transmitter receiver for video Duplex transceiver for use with bidirectional communication links such as Optocore when the device is used as an Optocore Router MADI etc Connection to and from WDM multiplexers For WDM common inputs ...

Page 12: ...th Division Multiplexer and DWDM Coarse Wavelength Division Multiplexer modules are available and can be configured for Mux and Demux by the manufacturer depending on the specified use of the device External auxiliary Mux and Demux ports can be added to the device to provide external connectivity to the WDM Optocore Fibre Optic Connection The device is equipped with the Optocore FX communication m...

Page 13: ...y power supply were to fail due to disruption of the power source or in the case of a power supply malfunction the device will automatically switch over to the redundant power supply In order to make the power supply to the device redundant both power inputs must be connected to the mains supply if possible to different phases circuits or even better having one of the power supplies connected to a...

Page 14: ...le lengths of up to 80 km worst case For Optocore networks and routers Multimode transceivers connected using a 50 µm OM3 fibre cable can be used for applications requiring cable lengths of up to 700 m worst case Single mode transceivers connected using a 9 µm fibre cable can be used for applications requiring cable lengths of up to 70 km worst case The total optical loss should be less than 6dB b...

Page 15: ... USB A to USB B cable between the PC and the device LAN Connection Use a standard twisted pair cable Cat 5 Cat 6 with RJ 45 connectors Word Clock Connection Use 75 Ω coaxial cable with BNC connectors Power Connection Use power cords with IEC C13 connectors ...

Page 16: ...ction point Each of the Route33s is equipped with two SD HD 3G SDI outputs and a BlackBurst output The Route66 and the two Route33s are connected with fibre cables Routing can be fixed or operator controlled using a third party integration controller such as VSM by the company LSB Fig 1 Connection of one Route66 and two Route33 units This example shows the use of Route66 and Route33s as a video on...

Page 17: ...ices when connecting external equipment to the RS485 ports D Sub 9 female 5 1 9 6 Locking system acc to 4 40 UNC Pin out RS232 Port RS232 Power Channel RXD TXD Internally bridged 5VS GND Pin 3 2 1 4 6 7 8 9 5 Use standard RS232 cable male female to connect to PC D Sub 9 female 5 1 9 6 Locking system acc to 4 40 UNC Pin out USB Port USB Channel VBUS D D GND Pin 1 2 3 4 USB device connector ...

Page 18: ...Output 5 Ω Input 75 Ω Drive level Output 1 Vpp Zero level Referring to GND 1 7 V Sense level Input 400 mVpp Remote Control Convention RS232 EIA TIA 232 57 600 Baud USB USB 2 0 Device 12 Mbit s LAN IEEE 802 3 10 100 Mbit s Power supply Type Switch mode universal input Mains voltage 100 240 V Frequency 50 60 Hz Power consumption Depending on the configuration of the device 32VA Max Security classifi...

Page 19: ...ch height 88 mm 3 46 inch 2RU frame 44 mm 1 73 inch 1RU frame depth 200 mm 7 87 inch Rear panel width 438 mm 17 25 inch Weight Dependent on the configuration of each specific device Please note Modifications that serve the purpose of technical improvement may be carried out without prior notification ...

Page 20: ...tain Warranty Service To return a defective product please contact your distributor dealer Our website http www BroaMan com provides a complete list of BroaMan distributors dealers Always ensure the careful handling of the device If possible these devices should always be transported or shipped in special shock absorbing transport cases If these are not available we recommend well padded packaging...

Page 21: ... Route Repeat 66 33 21 rev 1 0 Company Information Mailing Address BROAMAN GmbH Lohenstr 8 D 82166 Munich Gräfelfing Germany Telephone 49 0 89 8999640 Facsimile 49 0 89 89996455 Internet www BroaMan com Email ...

Reviews: