MODELS 744L • 744RL • 744RNL

WARNING  

  

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-

JURY TO PERSONS, OBSERVE THE FOLLOWING:

1.  Use this unit only in the manner intended by the manufacturer. 

If you have questions, contact the manufacturer at the address 

or telephone number listed in the warranty.

2.  Before servicing or cleaning unit, switch power off at service 

panel and lock the service disconnecting means to prevent 

power from being switched on accidentally. When the service 

disconnecting means cannot be locked, securely fasten a 

prominent warning device, such as a tag, to the service panel.

3. Installation work and electrical wiring must be done by a 

qualified person(s) in accordance with all applicable codes 

and standards, including fire-rated construction codes and 

standards.

4.  Sufficient air is needed for proper combustion and exhausting 

of gases through the flue (chimney) of fuel burning equip-

ment to prevent backdrafting. Follow the heating equipment 

manufacturer’s guideline and safety standards such as those 

published by the National Fire Protection Association (NFPA), 

and the American Society for Heating, Refrigeration and Air 

Conditioning Engineers (ASHRAE), and the local code authori-

ties.

5. When cutting or drilling into wall or ceiling, do not damage 

electrical wiring and other hidden utilities.

6.  Ducted fans must always be vented to the outdoors.
7.  Never place a switch where it can be reached from a tub or 

shower.

8.  A dimmer switch may be used to operate the light in this unit. 

Refer to the list of compatible dimmer switches on broan.com.

9.  Install this unit in a flat ceiling only.
10. For use in non fire rated installations only.
11.  Not for use in environmental air handling spaces.
12. If this unit is to be installed over a tub or shower, it must be 

marked as appropriate for the application and be connected 

to a GFCI (Ground Fault Circuit Interrupter) - protected branch 

circuit.

13.  Do not install in a ceiling thermally insulated to a value greater 

than R60.

14. This unit must be grounded.

CAUTION  

!

1.   For general ventilating use only. Do not use to exhaust 

hazardous or explosive materials and vapors.

2.   To avoid motor bearing damage and noisy and/or unbalanced 

impellers, use the cardboard protector (provided) to keep 

drywall spray, construction dust, etc. off power unit.

3.  Please read specification label on product for further 

information and requirements. 

RECESSED
LED FAN / LIGHT

READ AND SAVE THESE INSTRUCTIONS

To clean trim ring / baffle:

 Vacuum with a soft brush attachment 

or remove trim ring / baffle  and clean with a soft cloth and mild 

soap or detergent. Dry thoroughly before reinstalling.

To clean inside of housing:

 Remove trim ring / baffle and 

vacuum inside of housing with a soft brush attachment.

OPERATION

The fan and light can be operated using various combinations of 

on/off switches and controls:
•  Fan and light controlled with single on/off switch 

•  Fan and light controlled with separate on/off switches

•   Fan controlled with timer control

•   Selectable fan CFM - 50 or 80
See “Connect Wiring” section for various wiring options.

CLEANING

MAINTENANCE

Motor is permanently lubricated. Do not oil or disassemble motor.

For Warranty Statement, Service Parts, Technical 

Support, or to Register your product, please visit our 

website or call:

In the United States - Broan.com 800-637-1453 or 

NuTone.com 888-336-6151. In Canada - Broan.ca or 

NuTone.ca  877-896-1119

Installer: Leave this manual with 

the homeowner.

HOUSING 

MOUNTING 

BRACKET 

CEILING 

JOIST 

POWER 

CABLE 

TRIM RING / BAFFLE 

FINISHED CEILING 

4" ROUND 

DAMPER/DUCT 

CONNECTOR & 

4” ROUND 

DUCTWORK 

PLAN THE INSTALLATION

The unit can be installed anywhere between ceiling joists using 
mounting brackets provided.

*

 Install in a flat ceiling only.

Typical Installation

*

Summary of Contents for 744L

Page 1: ...hower it must be marked as appropriate for the application and be connected to a GFCI Ground Fault Circuit Interrupter protected branch circuit 13 Do not install in a ceiling thermally insulated to a value greater than R60 14 This unit must be grounded CAUTION 1 For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors 2 To avoid motor bearing damage and no...

Page 2: ...Equipment Floor 45 45 1 8 GAP 1 Install mounting brackets Slide the adjustable mounting brackets into the bracket channels on the housing CARDBOARD PROTECTOR Purchase separately INSULATION Place around and over Fan Housing ROOF CAP with built in damper FAN HOUSING POWER CABLE 4 IN ROUND DUCT 4 IN ROUND ELBOWS Seal gaps around Housing Seal duct joints with tape OR Keep duct runs short WALL CAP with...

Page 3: ...ed connectors to wire per local codes Fan and Light operated with single on off switch RED LAMP TO RED WIRING PLATE WHITE TO WHITE BLUE AND RED TO BLACK TOP BACK OF HOUSING 2 WIRE PLUS GROUND POWER CABLE GROUND TO WIRING PLATE FLUSH 5 Attach damper duct connector Snap the damper duct connector onto housing Make sure that tabs on the connector lock in housing slots Top of damper duct connector will...

Page 4: ... other lamp types Do not install a lamp indentified for use only in enclosed luminaries CLEARANCE HOLE 10 Install optional trim ring to trim ring baffle Trim rings not included with Model 744L Remove the cardboard protector from inside the housing collar Place trim ring over trim ring baffle Place fingers directly above and below tab as shown with arrows and squeeze to snap tab securely to trim ri...

Page 5: ... ducha debe estar marcada como apropiada para esta aplicación y conectarse a un GFCI interruptor accionado por pérdida de conexión a tierra en un circuito de derivación protegido 13 No se debe instalar en un techo que tenga un valor de aislamiento térmico superior a R60 14 Esta unidad debe estar conectada a tierra PRECAUCIÓN 1 Soloparausarsecomomediodeventilacióngeneral Nodebeusarse para la extrac...

Page 6: ...DE 1 8 pulg 3 mm 1 Instale los soportes de montaje Deslice los soportes de montaje ajustables en los canales del soporte de la cubierta PROTECTOR DE CARTÓN TAPA DE TECHO con regulador de tiro integrado TAPA DE PARED con regulador de tiro integrado CODOS REDONDOS DE 10 CM 4 PULG CONDUCTO REDONDO DE 10 CM 4 PULG CUBIERTA DEL VENTILADOR Selle las separaciones alrededor de la cubierta Selle con cinta ...

Page 7: ... y lámpara controlados mediante un interruptor único de encendido apagado ROJO LÁMPARA A ROJO PLACA DE CABLEADO BLANCO A BLANCO AZUL Y ROJO A NEGRO PARTE SUPERIOR PARTE POSTERIOR DE LA CUBIERTA CABLE ELÉCTRICO DE DOS HILOS Y CONEXIÓN A TIERRA TIERRA A PLACA DE CABLEADO AL RAS 5 Acople el conectador del regulador de tiro conducto Conecte a presión el conector del regulador de tiro conducto en la cu...

Page 8: ...a resorte en los agujeros que están en el soporte de la lámpara Centre el anillo deflector en la abertura del cielo raso 10 Instale el anillo opcional al anillo deflector No se incluyen anillos con el Modelo 744L Quite el protector de cartón del interior del collar de la cubierta Coloque el anillo sobre el anillo deflector Coloque los dedos directamente arriba y abajo de la lengüeta como se muestr...

Reviews: