background image

INST
ALLA
TION MANUAL

INST
ALLA

TION

9

4 ]  

Remove the wiring cover (shaded part on illustration below) by sliding it out from the hood 
and set it aside. 

5 ]  

Remove 7” Round Duct Plate from top/back of hood (see illustration below).

6 ]  

Remove Electrical Power Cable Knockout from top (vertical wiring) or back (horizontal wiring) 
of hood. Install an appropriate strain relief, 1/2” diameter (not included)

7” ROUND 

DUCT

PLATE

2 SCREWS

ELECTRICAL 

POWER CABLE

KNOCKOUT

RECIRCULATION 

COVER PLATE

SCREWS

NON-DUCTED INSTALLATION ONLY

7 ]  

Remove 3 screws retaining the recirculation cover plate (shaded part in illustration 
below) to the hood. Discard this plate with its screws.

Summary of Contents for BCSQ1 Series

Page 1: ...WWW BROAN COM Serial number 99045652 109B RANGE HOOD Series BCSQ1 INSTALLATION USE AND CARE MANUAL WWW BROAN CA ...

Page 2: ...Fan Blade Stainless Steel Cleaning Installation 7 13 Recommended Tools and Accessories for Installation 7 Install Ductwork Ducted Installations Only 7 Contents 8 Prepare the Hood 8 10 Prepare the Hood Location 11 Install the Hood 12 Connect the Wiring 12 13 LED Light Bulbs 13 Install the Filters 13 Wiring Diagram 14 Service Parts 15 Warranty 16 ...

Page 3: ...ncluding fire rated construction Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guidelines and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning ...

Page 4: ...and you know how to operate it B The fire is small and contained in the area where it started C The fire department has been called D You can fight the fire with your back to an exit Based on Kitchen Fire Safety Tips published by NFPA CAUTION For indoor use only For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors To avoid motor bearing damage and nois...

Page 5: ...the last selected speed Push this button again to turn OFF the blower NOTE If there is no speed selected all blower speed push buttons up the blower will not turn ON In that case press on the desired speed level push button to activate the blower BLOWER SPEED LEVEL PUSH BUTTONS When blower is ON change the blower speed by pressing the push button corresponding to the desired speed one line for LOW...

Page 6: ...grease such as frying and wok cooking Refer to installation instructions included with non ducted recirculation filters FAN BLADE The fan blade should be cleaned frequently Use a clean cloth soaked with warm detergent solution STAINLESS STEEL CLEANING Do Regularly wash with clean cloth or rag soaked with warm water and mild soap or liquid dish detergent Always clean in the direction of original po...

Page 7: ... 3 X 10 OR 7 ROUND DUCT FOR VERTICAL DISCHARGE HOUSE WIRING TOP OR BACK OF HOOD HOOD NOTE Distances over 24 are at the installer and user discretion 1 Determine whether hood will discharge vertically 3 x 10 or 7 round or horizontally 3 x 10 only 2 Decide where the ductwork will run between the hood and the outdoors 3 Choose a straight short duct run to allow the hood to perform most efficiently Lo...

Page 8: ... 7 ROUND DUCT CONNECTOR FIND PARTS BAG BEHIND THE DAMPER ASSEMBLY INSIDE OF HOOD 1 BULB SUCTION CUP TOOL 2 LED BULBS 4 W GU10 INSTALLED ON HOOD Prepare the Hood 1 If present remove all protective polyfilm from the hood and or parts 2 Using the tab remove the grease filters from the hood by pushing down and tilting filters out 3 Remove both screws holding damper assembly to hood Remove parts bag ca...

Page 9: ...Remove Electrical Power Cable Knockout from top vertical wiring or back horizontal wiring of hood Install an appropriate strain relief 1 2 diameter not included 7 ROUND DUCT PLATE 2 SCREWS ELECTRICAL POWER CABLE KNOCKOUT RECIRCULATION COVER PLATE SCREWS NON DUCTED INSTALLATION ONLY 7 Remove 3 screws retaining the recirculation cover plate shaded part in illustration below to the hood Discard this ...

Page 10: ... plate can be installed up to 1 2 on either side of the hood center 7 ROUND KNOCKOUT PLATE ALSO REMOVE VERTICAL KNOCKOUT PLATE 3 X 10 VERTICAL KNOCKOUT PLATE 3 X 10 HORIZONTAL KNOCKOUT PLATE FIGURE 1 A 7 ROUND DUCT PLATE SCREWS FIGURE 3 3 X 10 DAMPER ASSEMBLY TOP BACK EDGE OF HOOD DAMPER FLAP PIVOT SCREWS FIGURE 2 A FIGURE 2 B 9 Attach 3 x 10 Damper Assembly on top OR back of hood if using 3 x 10 ...

Page 11: ...VERTICAL DUCT ACCESS HOLE 1015 16 5 5 CENTER LINE HOOD MOUNTING SCREWS 4 ELECTRICAL ACCESS HOLE IN CABINET BOTTOM WOOD SHIMS RECESSED BOTTOM CABINETS ONLY CABINET FRONT 3 4 1Ǫ 1 7 16 12Ǭ 47 16 CABINET BOTTOM 12Ǭ 3 X 10 VERTICAL DUCTING CABINET BOTTOM CABINET FRONT HORIZONTAL DUCT ACCESS HOLE HOOD MOUNTING SCREWS 4 ELECTRICAL ACCESS HOLE IN WALL 3Ǭ CENTER LINE WOOD SHIMS RECESSED BOTTOM CABINETS ON...

Page 12: ...to hood and use metal foil duct tape to make joints secure and air tight Make sure the damper assembly or round duct plate enters the ductwork and that the damper opens and closes freely DUCTED INSTALLATION ONLY Connect the Wiring WARNING Risk of electric shock Electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards Before connecting wires switch...

Page 13: ... filters following instructions packed with the non ducted filter LED Light Bulbs 1 Align the bulb leads with the small indentations located on the border of the lamp location on hood see inset above then install the bulbs by placing the bulb leads into their grooves in the socket 2 Gently push upwards and turn clockwise until secure The BCSQ1 Series range hoods require two LED light bulbs 120 V 4...

Page 14: ...UE BROWN BROWN WHITE G Y O R W GREEN YELLOW ORANGE RED WHITE 120 V AC Line Neutral Ground 1 2 3 4 5 6 1 2 3 4 5 6 G Y G Y W W W W BK High BK O Medium BK O R Low R FAN MOTOR BN W BN BL Motor On Off Motor Speeds Lights On Off 1 2 3 W BK W BK ref 990729752_REV A BCSQ1 SERIES ...

Page 15: ... WOOD SCREWS 1 SUCTION CUP TOOL 1 S97020466 NON DUCTED FILTER TYPE XC SET OF 2 NON DUCTED INSTALLATION ONLY 1 S99527587 NON DUCTED FILTER CLIP KIT INCLUDES 4 CLIPS 1 ITEM NOT SHOWN BCSQ1 SERIES REPLACEMENT PARTS AND REPAIRS In order to ensure your unit remains in good working condition you must use Broan NuTone LLC or Venmar Ventilation ULC genuine replacement parts only Broan NuTone LLC or Venmar...

Page 16: ...r other freight charges incurred in the shipment of the Product or part to the Company If you must send the Product or part to the Company as instructed by the Company you must properly pack the Product or part the Company is not responsible for damage in transit The Company reserves the right to utilize reconditioned refurbished repaired or remanufactured Products or parts in the warranty repair ...

Reviews: