9

WIRING DIAGRAMS 

(CONT’D)

Line voltage wiring:
UL AWM 1015/1230, 600V, 105°C, VW-1,12 AWG; 
C

S

A TEW 600V, 105°C, FT1, 12 AWG.

Low voltage wiring: 

s

ame rating

s

 a

s

 high voltage

except 18 AWG.

  

Critic

a

l Ch

a

r

a

cteri

s

tic

s

1. If any of the original wire, a

s

 

s

upplied, mu

s

t be 

    replaced, u

s

e the 

s

ame equivalent wire. Wiring 

    mu

s

t comply with applicable code

s

, ordinance

s

 

    and regulation

s

.

 

2. Field wiring mu

s

t comply with applicable code

s

    ordinance

s

 and regulation

s

. U

s

e only Cla

ss

 1 

    wiring in

s

ide furnace compartment

s

For the 

us

e of 

a

 two-

s

t

a

ge he

a

t thermo

s

t

a

t or

a

n o

u

tdoor thermo

s

t

a

t, connect 

b

etween W1

a

nd W2. M

a

ke 

su

re th

a

t the 

S

e

as

on 

S

elect

s

witch i

s

 

s

et to the 

Mild

 Po

s

ition.

HI                                   BLACK
MED-HIGH

  

  

BLUE

MED-LOW  

  YELLOW

LOW                              RED

FAN MOTOR 

S

PEED COLOR

WIRING COLOR CODE 

BLK BLACK
BLU BLUE 
BRN BROWN 
GRN GREEN
GRY GREY 
ORG ORANGE
PNK PINK
PPL PURPLE
RED RED
WHT WHITE
YEL YELLOW

LEGEND

F1 F

us

e

E He

a

ting Element

KC He

a

ting Element

 Rel

a

y

K F

a

n Rel

a

y

HTL A

u

to-Re

s

et

 Therm

a

l Protector

MRHTL M

a

n

ua

l Re

s

et

 Therm

a

l Protector

M F

a

n Motor

TB Termin

a

l Block

T Tr

a

n

s

former Cl

ass

 2

HEAT He

a

t

L1, L2 

240 V Line 

Su

pply

N Ne

u

tr

a

l

HEAT 4

E

HTL

KC4

KC3

HEAT 3

HEAT 1

HEAT 2

KC2

KC1

K7

24 V

A

C

24VAC
COMMON OUT

FUSED 24 VAC
POWER OUT

CALL FOR FAN

CALL FOR COOL. 

REVERSING VALVE

CALL FOR HEAT 1

CALL FOR HEAT 2

CALL FOR COOL 1

BOARD POWER

SUPPLY

POWER

HE

A

T

 1

HE

A

T

 2

HEAT 3

HEAT 4

VO

U

T

GN

D

24VDC

24VDC

24VDC

24VDC

E

HTL

E

HTL

E

HTL

G

L1

COM

NO

COM

NO

COM

NO

COM

NO

Class 2 Transformer

Pri: 240 V 60 Hz 

Sec: 24 V 60 Hz 40 VA

YEL

YEL

RED

BLK

RED

BLK

BLK

BLK

BLK

RED

K

L

B

D

E

R

BLK

BLK

BLK

BLK

PPL

HEAT 4

HEAT 3

HEAT 2

HEAT 1

PNK

BRN

GRY

WHT

YEL

WHT

WHT

WHT

BLK

PPL

VENTILATION SPEED

MED-LO

LO

24VDC

4

6

2

5

1

3

PNK

RED

YEL

BLU

BLU

ORG

WHT

P2

P1

GRY

PNK

TB

T

HEAT INDICATOR

SEASON SELECT

GRY

PPL

PPL

PPL

BLK

BLK

BLK

BLK

BLK

BLK
BLK

BLK

RED

NC

YEL

Open: 93.3°C (200°F)

MRHTL1

WHT

WHT

PPL

PNK

X

13 C

O

M

X

13 H

E

A

T

X

1

3

 C

OOL

XF

M

R

L1

L1

L2C

O

M

L2

L2

BLK (HI)

BLU (MED-HI)

RED (LO)

YEL (MED-LO)

WHT

5

4

3

2

1

N

G

L

C

M

BLK

BLK

RED

RED

ORG

BLK

P2-8

P2-4

P2-3

P2-2

P2-1

P2-5

P2-6

P2-7

COM

KC5

NO

HEAT 5

MRHTL2

NC

C=COM
L=LINE
G=GROUND
N=NEUTRAL

1=LO
2=MED HI
3=MED HI
4=HI
5=HI

M

23 kW 240 VAC

Single phase

N

L2

RED

RED

RED

RED

RED

RED

RED

Y1

W2

W1

O

Y/

Y

2

G

R

C

BLK

24VDC

P2-3

P2-2

P2-1

P1-4

P1-3

P1-2

P1-1

24V

regulated

RLY PWR2

Heater

Logic

HEAT6 IN

HEAT5 IN

HEAT6

HEAT5

HEAT 5

RED

E

HTL

F1

 5 AMPS

P3

P3-1 P3-2

P3-3

P3-4

P3-5 P3-6

P3-7

GRY

PNK

PNK

WHT

PNK

PNK

PPL

GRY

PPL

WHT

GRY

BRN

PNK

PNK

WHT

BLK

WHT

WHT

WARNING

Risk of electric shock. Disconnect power before installation, servicing, maintenance or field wiring. Replace all panels before
operating. Failure to do so can result in electric shock causing severe injuries or death.

!

Summary of Contents for ECM SERIES

Page 1: ...ectrical condition and to premature furnace failure thus voiding the warranty Do not block the combustion air openings in the furnace Any blockage will result in improper overheat situation and may result in a fire hazard and or cause bodily harm The unit must have an uninterrupted or unbroken electrical ground to minimize personal injury if an electrical fault should occur When performing electri...

Page 2: ... positioned such as the door will not end up being on the top The door should be on the side of the furnace to ensure that the motor bearings are in their designed position In vertical downflow installations use only L or T shaped plenum with no openings or registers directly below furnace 3 INSTALLATION CLEARANCES As shipped from the factory each unit is approved for zero inch clearance If additi...

Page 3: ...calls for heat When MILD is selected it takes more time to bring all the elements online When COLD is selected the heating elements come online faster 3 LOW FACTORY SETTINGS SUBJECT TO CHANGE WITHOUT NOTICE This speed can only be run with heater off for cooling ventilation purposes only WARNING 240 VOLTS SINGLE PHASE TEMP RISE 0 20 in W C MODEL NO kW BTUH AMPS INCL MOTOR HP BLOWER C F SPEED RPM 21...

Page 4: ... uses Y1 as first stage and Y Y2 as second stage Make sure the thermostat is levelled on the wall and in appropriate location as per instructions supplied with the thermostat Because each installation is different an accurate reading of the current draw should be made with an AC meter Set the meter at a 2 A range A Set the anticipator at its highest setting B Disconnect the W1 thermostat wire from...

Page 5: ...tions for mounting and wiring are included with the kit 4 INTERLOCK CONNECTION When the electric furnace is used in combination with another device as for example a wood burning furnace it is recommended to perform the connection by referring to the wiring diagram below The burning furnace thermostat will then turn automatically on the blower in the electric furnace MAINTENANCE MOTOR The motor is ...

Page 6: ... 10941291 Service Blower Assembly for 21ECM10 and 21ECM15 10941292 Service Blower Assembly for 21ECM18 20 23 15 624664 Daughterboard 21ECM23 only 16 FK120 ECM 120 Volt Kit optional purchase separately Item not shown REPLACEMENT PARTS AND REPAIR In order to ensure your unit remains in good working condition you must use Broan NuTone genuine replacement parts only The Broan NuTone genuine replacemen...

Page 7: ... 3 P3 4 P3 5 P3 6 P3 7 GRY BRN PNK Open 93 3 C 200 F MRHTL2 WHT WHT WHT WHT RED RED MRHTL1 WHT WHT Line voltage wiring UL AWM 1015 1230 600V 105 C VW 1 12 AWG CSA TEW 600V 105 C FT1 12 AWG Low voltage wiring same ratings as high voltage except 18 AWG Critical Characteristics 1 If any of the original wire as supplied must be replaced use the same equivalent wire Wiring must comply with applicable c...

Page 8: ...C2 KC1 K7 24 VAC 24 VAC COMMON OUT FUSED 24VAC POWER OUT CALL FOR FA CALL FOR COOL REVERSING VALVE CALL FOR HEAT 1 CALL FOR HEAT 2 CALL FOR COOL 1 BOARD POWER SUPPLY POWER HEAT 1 HEAT 2 HEAT 3 HEAT 4 VOUT GND 24VDC 24VDC 24VDC 24VDC E HTL E HTL E HTL G L1 COM NO COM NO COM NO COM NO Class 2 Transformer Pri 240 V 60 Hz Sec 24 V 60 Hz 40 VA YEL YEL RED BLK RED BLK BLK BLK BLK RED K L B D E R BLK BLK...

Page 9: ...CALL FOR HEAT 1 CALL FOR HEAT 2 CALL FOR COOL 1 BOARD POWER SUPPLY POWER HEAT 1 HEAT 2 HEAT 3 HEAT 4 VOUT GND 24VDC 24VDC 24VDC 24VDC E HTL E HTL E HTL G L1 COM NO COM NO COM NO COM NO Class 2 Transformer Pri 240 V 60 Hz Sec 24 V 60 Hz 40 VA YEL YEL RED BLK RED BLK BLK BLK BLK RED K L B D E R BLK BLK BLK BLK PPL HEAT 4 HEAT 3 HEAT 2 HEAT 1 PNK BRN GRY WHT YEL WHT WHT WHT BLK PPL VENTILATION SPEED ...

Page 10: ...that such products will be free from defects in materials or workmanship for a period of sixty 60 months from the date of original purchase THERE ARE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE During this sixty month period Broan NuTone will at its option repair or replace without charge any product ...

Reviews: