background image

3

1. P

REPARE

 

INSTALLATION

. . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

2. S

ELECT

 

INSTALLATION

 

TYPE

. . . . . . . . . . . . . . . . . . . . . . . . . 3 

3. B

UILD

 

FRAMEWORK

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

4. I

NSTALL

 

UPPER

 

FLUE

 

MOUNTING

 

BRACKET

 (

DUCTED

 

INSTALLATION

 

ONLY

)   4

5. I

NSTALL

 

PLENUM

 (

NON

-

DUCTED

 

INSTALLATION

 

ONLY

) . . . . . . . . . 4

6. R

EMOVE

 

GREASE

 

FILTER

(

S

) . . . . . . . . . . . . . . . . . . . . . . . . . 5

7. I

NSTALL

 

THE

 

HOOD

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

8. C

ONNECT

 

WIRING

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

9. D

UCT

 

CONNECTION

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

10. P

REPARE

 

THE

 

DECORATIVE

 

FLUE

. . . . . . . . . . . . . . . . . . . . . . 8

11. I

NSTALL

 

THE

 

DECORATIVE

 

FLUE

. . . . . . . . . . . . . . . . . . . . .  8-9

12. R

EINSTALL

 

GREASE

 

FILTER

(

S

)  . . . . . . . . . . . . . . . . . . . . . . . 9

13. O

PERATION

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

14. C

ARE

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

15. R

EPLACEMENT

 

PARTS

. . . . . . . . . . . . . . . . . . . . . . . . . . . .  11

16. W

ARRANTY

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

TABLE OF CONTENTS

1. PREPARE INSTALLATION

NOTE: Before proceeding to the installation, check the contents of the box. If items are missing or damaged, contact the retailer.
Make sure that the following items are included:

- Hood
-  Decorative flue assembly (lower and upper flues)
-  Upper flue mounting bracket
- Aluminum grease filter(s) (1 for 24-in. width hood, 2 for 30-in. and 
 

36-in. width hoods)

- Installation 

instructions

-  Parts bag:  6 M4 x 38 Phillips 9 mm round head mounting screws,

2

 

M4 x 12 Phillips 9 mm

 

round head screws, 

2 washers and 3

 

wire connectors

Parts sold separately:

-  Ducts, elbows, wall and roof caps.
-  Optional flue extension for

 

ceilings of 9 ft. or more: models AEEW48SS 

(stainless steel), AEEW48BLS (black stainless steel) or AEEW48WH (white).

-  Non-duct kit model ARKEW48, mandatory for non-ducted installation.
NOTE: During installation, protect countertop and/or cooktop.

2.  SELECT INSTALLATION TYPE

2.1 N

ON

-D

UCTED

 I

NSTALLATION

 

The ARKEW48 non-duct kit is required for a non-ducted installation.

2.2 D

UCTED

 I

NSTALLATION

 

Plan where and how the ductwork will be installed.
A straight, short duct run will allow the hood to perform most efficiently. Long duct 
runs, elbows and transitions will reduce the performance of the hood. Use as few 
of them as possible. Larger ducting may be required for longer duct runs.
Install wall or roof cap. Connect 6” round metal ductwork to cap and work back 
towards the hood location. Use 2” metal foil duct tape to seal the joints.

2.3 A

LL

 I

NSTALLATIONS

 

The minimum hood distance above cooktop is 24”. A maximum of 30” above 

 

cooktop is recommended for best capture of cooking impurities.

 

Distances over 30” are at the installer and users discretion providing that ceiling 

 

height and decorative flue length allow it.

 

NOTE:  Ceilings of 9 ft. or more require flue extension model AEEW48SS (stainless

 

 

steel), AEEW48BLS (black stainless steel) or AEEW48WH (white).

6” R

OUND

DUCT

R

OOF

 

CAP

6” R

OUND

ELBOW

W

ALL

 

CAP

H

OOD

D

ECORATIVE

FLUE

HH0281A

24” 

MINIMUM

 

ABOVE

COOKING

 

SURFACE

    WARNING

!

When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses and gloves.

HR0224A

(1) D

ECORATIVE

 

FLUE

     

ASSEMBLY

(1) U

PPER

 

FLUE

MOUNTING

 

BRACKET

(1 

OR

 2) G

REASE

 

FILTER

(

S

)

(6) M4 

X

 38 P

HILLIPS

 

ROUND

 

HEAD

 

SCREWS

 

(2) M4 

X

 12 P

HILLIPS

 

ROUND

 

HEAD

 

SCREWS

(2) W

ASHERS

(3) W

IRE

 

CONNECTORS

Summary of Contents for EW48 Series

Page 1: ...Serial number 99046144C WW WW BR CHIMNEY RANGE HOOD EW48 Series INSTALLATION USE AND CARE MANUAL ...

Page 2: ...nly 2 For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors 3 To avoid motor bearing damage and noisy and or unbalanced impeller keep drywall spray construction dust etc off power unit 4 Your hood motor has a thermal overload which will automatically shut off the motor if it becomes overheated The motor will restart when it cools down If the motor conti...

Page 3: ...allation protect countertop and or cooktop 2 SELECT INSTALLATION TYPE 2 1 NON DUCTED INSTALLATION The ARKEW48 non duct kit is required for a non ducted installation 2 2 DUCTED INSTALLATION Plan where and how the ductwork will be installed A straight short duct run will allow the hood to perform most efficiently Long duct runs elbows and transitions will reduce the performance of the hood Use as fe...

Page 4: ...llips 9 mm round head mounting screws in wall framing do not completely tighten the screws at this time 4 INSTALL UPPER FLUE MOUNTING BRACKET DUCTED INSTALLATION ONLY Center the upper flue mounting bracket with the center line previously drawn in step 3 and place it flush with the ceiling Use the upper flue mounting bracket as a template to mark the position of its screws Secure the upper flue mou...

Page 5: ... right Tighten both screws completely WARNING BE CAREFUL when installing the decorative flue and hood they may have sharp edges HOLE LOCATIONS 6 REMOVE GREASE FILTER S Lay the back side of the hood flat on a table Use a piece of cardboard to avoid damaging the table or the hood To remove the grease filter s pull down on the metal latch tab and tilt each filter downward Set filters aside NOTE There...

Page 6: ...a UL approved strain relief not included on the house power cable at 4 from the cable end Run the power cable in the junction box cover opening then use the strain relief to secure the house power cable to the junction box cover Connect power cable to range hood wiring using included wire connectors Connect BLACK to BLACK WHITE to WHITE and GREEN or BARE WIRE to GREEN DO NOT FORGET TO CONNECT THE ...

Page 7: ...nd metal ductwork to wall cap and 90 elbow over duct collar then install the 90 elbow over the adapter damper on the hood Use metal foil duct tape to seal the joints NON DUCTED INSTALLATION Remove the damper flaps Measure the length of 6 round flexible duct included in the non duct kit required from the top of the hood to the plenum Slide the 6 round flexible metal duct over the adapter on the hoo...

Page 8: ...er and upper flues are included with the hood but for ceilings of 9 ft or more discard the provided lower and upper flues and use the optional flue extension part no AEEW48SS stainless steel AEEW48BLS black stainless steel or AEEW48WH white sold separately Remove the upper flue from inside the lower flue Remove protective plastic film covering the lower flue only 11 INSTALL THE DECORATIVE FLUE Car...

Page 9: ... plenum Secure the upper flue to the plenum using 2 M4 x 12 Phillips 9 mm round head screws Remove protective plastic film covering the upper flue and the hood 11 INSTALL THE DECORATIVE FLUE CONTINUED 12 REINSTALL GREASE FILTER S ALL INSTALLATIONS To reinstall the grease filters align rear filter tabs with slots in the hood Pull down the metal latch tab push each filter into position and release M...

Page 10: ...shwasher using a non phosphate detergent Discoloration of the filters may occur if using phosphate detergents or as a result of local water conditions but this will not affect filter performance This discoloration is not covered by the warranty To minimize or prevent discoloration hand wash filters using a mild detergent Non ducted Filters Change the non duct recirculation filters every 6 months P...

Page 11: ...TH BRACKET 1 1 1 S97021439 DECORATIVE UPPER AND LOWER FLUES WHITE 1 S97021440 DECORATIVE UPPER AND LOWER FLUES BLACK STAINLESS STEEL 1 1 2 S99527461 DAMPER ASSEMBLY 1 1 1 3 S99010479 LED MODULE 1 1 1 4 S97021444 MOTOR AND BLOWER ASSEMBLY 1 1 1 5 S97021443 ELECTRONIC BOARD 1 1 1 6 S99010476 ALUMINUM GREASE FILTERS SET OF 2 1 1 S99010477 ALUMINUM GREASE FILTERS SET OF 2 1 7 S99010473 NON DUCT RECIRC...

Page 12: ...r freight charges incurred in the shipment of the Product or part to the Company If you must send the Product or part to the Company as instructed by the Company you must properly pack the Product or part the Company is not responsible for damage in transit The Company reserves the right to utilize reconditioned refurbished repaired or remanufactured Products or parts in the warranty repair or rep...

Reviews: