5
7. INSTALL THE HOOD
1. Align the hood with the center line previously marked on the wall. Gently
lower the hood until it securely engages the screws on the wall.
2. Level the hood and completely tighten the screws on the wall.
3. Secure the hood to the wall by inserting 2 M4 x 38 Phillips 9 mm round head
mounting screws and 2 washers in the lower back of the hood (see back view
at right). Tighten both screws completely.
WARNING
!
BE CAREFUL when installing the decorative flue and hood, they may have sharp edges.
H
OLE
LOCATIONS
6. REMOVE GREASE FILTER(S)
Lay the back side of the hood flat on a table. Use a piece of cardboard to
avoid damaging the table or the hood.
To remove the grease filter(s), pull down on the metal latch tab and tilt
each filter downward. Set filters aside.
NOTE: There is only one filter on 24-in. width hoods.
HD1148
Detach the junction box cover from the top of the hood by removing both retaining
screws. Set aside the cover and the screws.
HO0296