background image

MODELS EWT1306SS • EWT1366SS

Page 8

INSTALL THE HOOD 

(Non-Ducted Hoods Only)

7.  Measure and install 6” round steel ductwork to the blower 

exhaust opening on top of hood. Use duct tape to make all 
joints secure and air tight.

8.  Hold hood up close to wall mounting location and plug 

power cord into wall outlet.

9.  Align the hood and center it above the hood mounting 

bracket. Make sure ductwork on hood lines up and attaches 
to ductwork in ceiling. Gently lower the hood until it securely 
engages the bracket.

10. Use duct tape to make all joints secure and air tight.

11. With the hood hanging in place, drill through both holes 

located in the inside lower back of hood using a 5/16” drill 
bit. Insert the included drywall anchors into the drilled holes 
(one for each hole). Install (2) washers and (2) no. 8 x 1½” 
mounting screws through the hood back and into the drywall 
anchors. Verify that the hood is centered and leveled. Tighten 
all screws completely. 

12. Reinstall grease filters by aligning rear filter tabs with slots 

in the hood. Pull down the metal latch tab, push filter into 
position and release. Make sure filters are securely engaged 
after installation.

13. Slightly push aside the upper flue to avoid any damage 

while installing the lower flue to the hood top. Secure the 
lower flue bracket to the wall using (2) no. 8 x 1½” mounting 
screws.

14. Slide the upper flue upward until it is aligned with its upper 

flue mounting bracket. The bracket should be inside the flue. 
Secure the upper flue to the upper flue mounting bracket 
using (2) no. 8 x 3/8” mounting screws.

15. Remove protective plastic film covering the upper flue and 

the hood.

HO0366

UPPER 

FLUE

UPPER FLUE MOUNTING BRACKET

DUCT LENGTH

DECORATIVE

FLUE

6” ROUND

STEEL DUCT

HD1259A

NOTE: Non-ducted installations require Non-Duct Kit, 
Model ARKBWT (purchase separately).

1. CAUTION: Use only flexible duct provided.
2.  Do not remove the protective plastic film covering the 

decorative flue and the hood at this time.

3.  Lay the back side of the hood flat on a table. Use a piece 

of cardboard to avoid damaging the table or the hood.

NON-DUCT KIT MODEL ARKBWT CONTENTS

NON-DUCT

PLENUM

2 TIE

WRAPS

FLEXIBLE DUCT

NON-DUCTED

RECIRCULATION

FILTERS

NON-DUCT PLENUM

COLLAR

8  MOUNTING
SCREWS
(ST4 x 8
Round Head)

HR0229A

HD1258

INSIDE BACK OF HOOD

MOTOR/BLOWER 

ASSEMBLY

HOLES LOCATION

SIDE VIEW

Ø 5/16” TYP.

Summary of Contents for EWT1306SS

Page 1: ...requently Grease should not be allowed to accumulate on fan or filters d Use proper pan size Always use cookware appropriate for the size of the surface element WARNING TO REDUCE THE RISK OF INJURY TO PERSON S IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING 1 SMOTHER FLAMES with a close fitting lid cookie sheet or metaltray thenturnofftheburner BECAREFULTOPREVENT BURNS IF THE FLAMES ...

Page 2: ...e hood During construction renovation cover the range hood to make sure no dust sticks to the stainless steel surface Avoid When choosing a detergent Any cleaners that contain bleach will attack stainless steel Any products containing chloride fluoride iodide bromide will deteriorate surfaces rapidly Any combustible products used for cleaning such as acetone alcohol ether benzol etc are highly exp...

Page 3: ...ceiling height permits 6 ROUND DUCT ROOF CAP ROUND ELBOW 26 MIN ABOVE COOKING SURFACE WALL CAP HOOD DECORATIVE FLUE HH0302A 10 1 2 WALL CAP 26 36 ABOVE COOKING SURFACE HOOD DECORATIVE FLUE ROOF CAP 6 ROUND DUCT ROUND ELBOW 11 7 8 TO CENTER OF BRACKET HOLES HOOD MOUNTING BRACKET 3 3 8 DUCT CENTER LINE HH0303A PREPARE THE HOOD Unpack hood and check contents You should receive 1 Hood 1 Decorative Flu...

Page 4: ...iance is equipped with a cord with incorporated grounding wire with a grounding plug The plug must be plugged into an outlet that is properly installed and grounded NOTE A recessed clock outlet is recommended 2 Position the electrical outlet within the space covered by the decorative flue and where it will not interfere with the round duct Make sure the outlet does not interfere with the mounting ...

Page 5: ...nd flue length permit MOUNTING BRACKET LOCATION ABOVE 36 HIGH COOKTOP NOTE On 8 ft ceilings Hood distance above cooktop is Minimum 26 Maximum 36 for both ducted and non ducted discharge On 9 ft ceilings Hood distance above cooktop is Minimum 32 Maximum 36 for both ducted and non ducted discharge On 10 ft ceilings Hood distance above cooktop is Minimum 32 Maximum 36 for both ducted and non ducted d...

Page 6: ... the hood 3 Remove the grease filters by pulling down the metal latch tab and tilting filters downward to remove 4 Carefully rotate hood upright HD1258 INSIDE BACK OF HOOD MOTOR BLOWER ASSEMBLY HOLES LOCATION SIDE VIEW Ø5 16 TYP 5 To make sure there will be adequate clearance between top of hood and lower flue mounting bracket for ductwork Elbow must be located below lower flue mounting bracket 6 ...

Page 7: ...x 3 8 mounting screws 15 Remove protective plastic film covering the upper flue and the hood HO0366 UPPER FLUE UPPER FLUE MOUNTING BRACKET 8 8 6 ROUND DUCT ELBOW 9 Measure and install 6 round steel ductwork to roof cap or wall cap and 90o elbow over the blower exhaust opening on top of hood Use duct tape to make all joints secure and air tight 10 Plug hood power cord into the outlet INSTALL THE HO...

Page 8: ...nto position and release Make sure filters are securely engaged after installation 13 Slightly push aside the upper flue to avoid any damage while installing the lower flue to the hood top Secure the lower flue bracket to the wall using 2 no 8 x 1 mounting screws 14 Slide the upper flue upward until it is aligned with its upper flue mounting bracket The bracket should be inside the flue Secure the...

Page 9: ... 8 x 3 8 pan head screws 6 Measure distance A This will be the HD1181 HD1179 LOWER FLUE MOUNTING BRACKET LOWER FLUE 13 Align the hood and center it above the hood mounting bracket Gently lower the hood until it securely engages the bracket 14 With the hood hanging in place drill through both holes located in the inside lower back of hood using a 5 16 drill bit Insert the included drywall anchors i...

Page 10: ...ntact a certified service depot for all replacement parts and repairs B C D E F G H I J K L KEY CUSTOMER MODEL NO PART NO DESCRIPTION QTY 1 S99528454 Decorative Upper and Lower Flues 1 2 S99010497 Mounting Bracket set of 3 1 3 S99529088 Plastic box of PCB 1 4 S99010491 30 µf Capacitor 1 5 S1104711 Main PCB 1 6 S1104709 Control Assembly 1 7 S99010499 Damper flap 1 8 S1104710 600CFM Motor Blower Ass...

Page 11: ... freight charges incurred in the shipment of the Product or part to the Company If you must send the Product or part to the Company as instructed by the Company you must properly pack the Product or part the Company is not responsible for damage in transit The Company reserves the right to utilize reconditioned refurbished repaired or remanufactured Products or parts in the warranty repair or repl...