background image

MODELS EWT1306SS • EWT1366SS

Page 9

length of the 
extended flex 
duct.

7. Attach 

aluminum 
flexible duct 
to the blower 
discharge 
opening with a 
tie wrap.

8.  Attach flexible 

duct to non-
duct plenum 
collar and 
secure with tie wrap. Tape all joints with duct tape.

NOTE: 10-ft. ceilings require 10-ft. Flue Extension Model 
FXN53SS  (purchase separately). Discard the upper flue 
supplied with your hood and replace it with the Model 
FXN53SS flue extension.

9.  Remove the upper flue from inside the lower flue. Install 

the lower flue bracket to the lower flue using (2) flue 
bracket screws (no. 8 x 3/8”). Make sure that the bracket is 
positioned inside of the lower flue flanges - with the slots on 
top. Carefully replace the upper flue inside the lower flue. 
Remove protective plastic film covering the lower flue only.

10. Carefully place both flues into the recessed area of of hood 

top. Slightly push aside the upper flue to avoid any damage 
while installing the lower flue to the hood top. Secure the 
lower flue bracket to the wall using (2) no. 8 x 1½” mounting 
screws.

11. Attach non-duct plenum with collar to upper flue using  

(4) no. 8 x 3/8” pan head screws.

12. Hold hood up close to wall mounting location and plug 

power cord into wall outlet.

HO0388

4.  Remove the 

grease filters 
by pulling 
down the 
metal latch 
tab and 
tilting filters 
downward to 
remove.

5.  Attach non-duct collar to non-duct plenum using  

(4) no. 8 x 3/8” pan head screws.

6. Measure 

distance “A”. 
This will be the 

HD1181

HD1179

LOWER FLUE MOUNTING BRACKET

LOWER 

FLUE

13. Align the hood and center it above the hood mounting bracket. 

Gently lower the hood until it securely engages the bracket.

14. With the hood hanging in place, drill through both holes located 

in the inside lower back of hood using a 5/16” drill bit. Insert the 
included drywall anchors into the drilled holes (one for each hole). 
Install (2) washers and (2) no. 8 x 1½” mounting screws through 
the back of the 
hood and into the 
drywall anchors. 
Verify that the 
hood is centered 
and leveled. 
Tighten all screws 
completely.

15. Attach (2) two non-duct recirculation filters to sides of 

blower by aligning key lock slot and rotating until filters lock 
into place.

 

For replacement non-duct recirculation filters - purchase 
S99010494 (set of 2 filters).

16. Reinstall grease filters by aligning rear filter tabs with 

slots in the hood. Pull down the metal latch tab, push filter 
into position and release. Make sure filters are securely 
engaged after installation.

17. Slide up the upper flue upward until it is aligned with its 

upper flue mounting bracket. The bracket should be inside 
the flue. Secure the upper flue to the upper flue mounting 
bracket using (2) no. 8 x 3/8” mounting screws.

18. Remove protective plastic film covering the flue and the hood.

HO0366

UPPER 

FLUE

UPPER FLUE MOUNTING BRACKET

A

NON-DUCT PLENUM

6”  ALUMINUM

FLEX  DUCT

BLOWER 
DISCHARGE
OPENING
(without flaps)

3-5/8”

NON-DUCT COLLAR

HD1260A

HD1258

INSIDE BACK OF HOOD

MOTOR/BLOWER 

ASSEMBLY

HOLES LOCATION

SIDE VIEW

Ø 5/16” TYP.

Summary of Contents for EWT1306SS

Page 1: ...requently Grease should not be allowed to accumulate on fan or filters d Use proper pan size Always use cookware appropriate for the size of the surface element WARNING TO REDUCE THE RISK OF INJURY TO PERSON S IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING 1 SMOTHER FLAMES with a close fitting lid cookie sheet or metaltray thenturnofftheburner BECAREFULTOPREVENT BURNS IF THE FLAMES ...

Page 2: ...e hood During construction renovation cover the range hood to make sure no dust sticks to the stainless steel surface Avoid When choosing a detergent Any cleaners that contain bleach will attack stainless steel Any products containing chloride fluoride iodide bromide will deteriorate surfaces rapidly Any combustible products used for cleaning such as acetone alcohol ether benzol etc are highly exp...

Page 3: ...ceiling height permits 6 ROUND DUCT ROOF CAP ROUND ELBOW 26 MIN ABOVE COOKING SURFACE WALL CAP HOOD DECORATIVE FLUE HH0302A 10 1 2 WALL CAP 26 36 ABOVE COOKING SURFACE HOOD DECORATIVE FLUE ROOF CAP 6 ROUND DUCT ROUND ELBOW 11 7 8 TO CENTER OF BRACKET HOLES HOOD MOUNTING BRACKET 3 3 8 DUCT CENTER LINE HH0303A PREPARE THE HOOD Unpack hood and check contents You should receive 1 Hood 1 Decorative Flu...

Page 4: ...iance is equipped with a cord with incorporated grounding wire with a grounding plug The plug must be plugged into an outlet that is properly installed and grounded NOTE A recessed clock outlet is recommended 2 Position the electrical outlet within the space covered by the decorative flue and where it will not interfere with the round duct Make sure the outlet does not interfere with the mounting ...

Page 5: ...nd flue length permit MOUNTING BRACKET LOCATION ABOVE 36 HIGH COOKTOP NOTE On 8 ft ceilings Hood distance above cooktop is Minimum 26 Maximum 36 for both ducted and non ducted discharge On 9 ft ceilings Hood distance above cooktop is Minimum 32 Maximum 36 for both ducted and non ducted discharge On 10 ft ceilings Hood distance above cooktop is Minimum 32 Maximum 36 for both ducted and non ducted d...

Page 6: ... the hood 3 Remove the grease filters by pulling down the metal latch tab and tilting filters downward to remove 4 Carefully rotate hood upright HD1258 INSIDE BACK OF HOOD MOTOR BLOWER ASSEMBLY HOLES LOCATION SIDE VIEW Ø5 16 TYP 5 To make sure there will be adequate clearance between top of hood and lower flue mounting bracket for ductwork Elbow must be located below lower flue mounting bracket 6 ...

Page 7: ...x 3 8 mounting screws 15 Remove protective plastic film covering the upper flue and the hood HO0366 UPPER FLUE UPPER FLUE MOUNTING BRACKET 8 8 6 ROUND DUCT ELBOW 9 Measure and install 6 round steel ductwork to roof cap or wall cap and 90o elbow over the blower exhaust opening on top of hood Use duct tape to make all joints secure and air tight 10 Plug hood power cord into the outlet INSTALL THE HO...

Page 8: ...nto position and release Make sure filters are securely engaged after installation 13 Slightly push aside the upper flue to avoid any damage while installing the lower flue to the hood top Secure the lower flue bracket to the wall using 2 no 8 x 1 mounting screws 14 Slide the upper flue upward until it is aligned with its upper flue mounting bracket The bracket should be inside the flue Secure the...

Page 9: ... 8 x 3 8 pan head screws 6 Measure distance A This will be the HD1181 HD1179 LOWER FLUE MOUNTING BRACKET LOWER FLUE 13 Align the hood and center it above the hood mounting bracket Gently lower the hood until it securely engages the bracket 14 With the hood hanging in place drill through both holes located in the inside lower back of hood using a 5 16 drill bit Insert the included drywall anchors i...

Page 10: ...ntact a certified service depot for all replacement parts and repairs B C D E F G H I J K L KEY CUSTOMER MODEL NO PART NO DESCRIPTION QTY 1 S99528454 Decorative Upper and Lower Flues 1 2 S99010497 Mounting Bracket set of 3 1 3 S99529088 Plastic box of PCB 1 4 S99010491 30 µf Capacitor 1 5 S1104711 Main PCB 1 6 S1104709 Control Assembly 1 7 S99010499 Damper flap 1 8 S1104710 600CFM Motor Blower Ass...

Page 11: ... freight charges incurred in the shipment of the Product or part to the Company If you must send the Product or part to the Company as instructed by the Company you must properly pack the Product or part the Company is not responsible for damage in transit The Company reserves the right to utilize reconditioned refurbished repaired or remanufactured Products or parts in the warranty repair or repl...

Reviews: