background image

4

FREQUENTLY ASKED QUESTIONS (FAQS)

1.  What does the Broan Automatic Make-Up Air Damper do?

The Broan Automatic Make-Up Air Damper (the “Damper”) provides a pathway for fresh 

air to enter a home from outdoors when a compatible exhaust device is operating.  The 

Damper opens when a compatible BEST, Broan Elite or Broan range hood is operating, 

thereby creating a known, controlled point for fresh air to enter the home while air is 

being exhausted from the building by the range hood.  
By operating in this manner, the Damper provides two key benefits for the home:
•  It facilitates air exchange between indoors and outdoors, by helping to allow fresh 

air into the home to replace air which is exhausted out of the home.  

•  By allowing fresh air into the building when a compatible exhaust device is on, the 

Damper helps to avoid negative pressure conditions within the home which may 

interfere with the proper operation of combustion equipment within the home.

Overall, the Damper let’s your BEST, Broan Elite or Broan exhaust devices do their job 

more effectively and without interfering with the proper operation of other home sys-

tems.

2.  Does the “Damper” provide combustion air for combustion appliances like a 

water heater or a furnace?

No. The Damper helps to replace air which is exhausted by a compatible range hood.  

But it does NOT help to replace air which is drawn from the indoors by a combustion 

appliance like a natural gas water heater, and it should not be relied upon to perform 

this function. One main reason for this restriction is that the Damper is only open when 

the range hood that it’s connected to is operating.  So there is no assurance that the 

Damper would be open when other appliances, like a water heater, are operating.  Other 

means must be provided to ensure adequate combustion air for these appliances. 

3.  How do I know if I need make-up air for my range hood?

In some cases the local building code may tell you that make-up air is necessary.  For 

example, some codes specify that range hoods with exhaust flows of 300 cubic feet per 

minute (CFM) or higher need a mechanical system to introduce make-up air.
In other cases, make-up air for a range hood is desirable regardless of whether code 

requires it.  This is especially true for:
•  larger range hoods (those over 300 cfm)
•  homes which are well air-sealed - so outside air may not be able to easily find its 

way into the home through cracks, to replace air which is exhausted out

•  homes with atmospherically vented combustion appliances (i.e. a water heater or 

natural draft fireplace), which are more susceptible to improper venting if depres-

surization occurs in the home.

In homes with any one of these factors make-up air is advised.  And in homes with 

more than one of these conditions make-up air for the range hood is strongly advised.

4.  What are the benefits of providing make-up air to replace air which is exhausted 

out of the home by a range hood?

Range hoods are designed to pull out pollutants like cooking odors or moisture at the 

source, so they don’t linger in the home.  Because these fans pull air out of the house, 

this air needs to be replaced with “new” air from outdoors.  Normally this make-up air 

enters the home through cracks and holes in the “shell” of the building.  But modern 

homes are air-sealed much more thoroughly so there are not as many cracks and open-

ings.  Plus some exhaust fans like range hoods exhaust a lot more air than can be 

replaced through normal cracks in the building shell.
By providing an intentionally designed opening for fresh air to replace air which is ex-

hausted out by the range hood, several important benefits result:
•  The make-up air entering the home comes in at a known point, where it is also 

filtered

•  Negative pressure conditions, which could arise if air is exhausted from a home 

without being replaced by new fresh air, are prevented

•  Pollutants are more effectively exhausted from the home while fresh replacement 

air is drawn into the home, improving ventilation

5.  Does ASHRAE 62.2-2007 – “Ventilation and Acceptable Indoor Air Quality in 

Low-Rise Residential Buildings” – require the use of a make-up air damper?

ASHRAE 62.2-2007 does not specifically require make-up air dampers. In a few limited 

circumstances, this standard does require that net exhaust flows from a house be lim-

ited.  For example, Section 6.4 of the standard limits the net exhaust flow from a home’s 

two largest exhaust appliances if the home has atmospherically vented or solid-fuel 

burning appliances located within the pressure boundary of the house. This standard is 

available at www.ashrae.org. 

6.  Can I use the Broan Automatic Make-Up Air Damper with other equipment in my 

home?  

No. The Broan Automatic Make-Up Air Damper may only be used with compatible BEST, 

Broan Elite or Broan range hoods. More information on exact models of the Damper and 

compatible exhaust devices can be found in the Broan Automatic Make-Up Air Damper 

Application Guide.

7.  What are the different ways that the Damper can be installed in my home?  

The most common way to install the Damper is to connect it to a home’s central duct 

system.  In this application, outside fresh air enters the home through the Damper and 

is then routed and distributed through the home’s ducts.  More information on this 

installation approach can be found in the Broan Automatic Make-Up Air Damper Ap-

plication Guide on our web site: www.broan.com.

8.  What if my home doesn’t have ducts?

Homes without ducts can still utilize the Damper to help replace air which is exhausted 

from the home by the range hood.  An installation illustration for this situation is in-

cluded in the Broan Automatic Make-Up Air Damper Application Guide on our web site: 

www.broan.com.

9.  What happens after a power outage?

The Damper system and the associated exhaust devices will not lose their settings 

following a power outage.  So the system will resume its normal operation following a 

power outage, based on the settings it used prior to the outage.

99044953E

Summary of Contents for MD10TU

Page 1: ...Insulate the duct and damper to prevent build up of condensation in cold weather climates Vapor barriers on both sides of insulation are recommended PLAN THE INSTALLATION Planning the installation first requires selecting the most appropriate installation ap proach The chart below offers suggestions for the most effective installation approach by considering a few important factors Further details...

Page 2: ...re It may not operate at low speeds since the pressure is below this limit MULTIPLE DAMPERS More than one damper may be required to balance the system If more than one is required use 1 MD6TU or MD8TU and then use the MD6 or MD8 dampers as ad ditional dampers INSTALLATION OF PRESSURE SWITCH AND PROBE For the probe pressure switch to work effectively the roof or wall cap must have a spring loaded d...

Page 3: ...ion and venting of all combustion equipment in the home FALSE TRIPPING Under certain extreme conditions there could be false tripping of the damper opening when the range hood blower is off If false tripping is encountered place an in line backdraft damper 7 model no 97 8 model no 438 10 model no 421 between the probe and the roof or wall cap SERVICE PARTS 97018853 Pressure Switch Kit 97013273 24V...

Page 4: ... the home by a range hood Range hoods are designed to pull out pollutants like cooking odors or moisture at the source so they don t linger in the home Because these fans pull air out of the house this air needs to be replaced with new air from outdoors Normally this make up air enters the home through cracks and holes in the shell of the building But modern homes are air sealed much more thorough...

Page 5: ...SERVER POUR USAGE RÉSIDENTIEL SEULEMENT MODÈLES MD6TU MD8TU MD10TU EMPLACEMENT DE LA PRISE D AIR EXTÉRIEUR La conception et l emplacement adéquats de la prise d air extérieur sont indispensables au bon fonctionnement et à la fiabilité du clapet pour faire pénétrer de l air frais dans la maison Il importe de respecter les exigences suivantes lors du positionnement de la prise d air La prise d air e...

Page 6: ...me Si vous utilisez plusieurs clapets choisissez un 1 clapet MD6TU ou MD8TU puis utilisez les modèles MD6 ou MD8 comme clapets additionnels INSTALLATION DU MANOCONTACTEUR ET DE LA SONDE Pour que la sonde et le manocontacteur fonctionnent correctement le capuchon mural ou de toit doit avoir un clapet à ressort Les produits Broan suivants sont recommandés MODÈLES DE CAPUCHON DE TOIT 437 Haute capaci...

Page 7: ...stion Effectuez le câblage tel qu illustré NOIR LIGNE BLANC NEUTRE VERT TERRE CLAPET D AIR DE COMPENSATION TRANSFORMATEUR 24V MANOCONTACTEUR DIAGRAMME DE CÂBLAGE CLAPETS MULTIPLES CLAPET D AIR DE COMPENSATION 24V 24V 24V 24V 20V BORNES 24V CÂBLAGE DUTRANSFORMATEUR DÉCLENCHEMENT INDÉSIRABLE Dans certaines conditions extrêmes le clapet peut se déclencher alors qu il ne le devrait pas s ouvre alors q...

Page 8: ...e stagnent pas dans la maison Puisque ces ventilateurs évacuent l air de la maison celui ci doit être remplacé par de l air neuf de l extérieur Normalement cet air de compensation entre dans l habitation par les ouvertures et les fentes de l enveloppe de l édifice Or les maisons modernes sont beaucoup plus étanches et ne présentent plus autant de fentes et d ouvertures De plus certains ventilateur...

Page 9: ...our éviter la condensation Il est conseillé de placer un coupe vapeur des deux côtés de l isolant REGULADOR DE AIRE AUTOMÁTICO DE REPUESTO CON TRANSFORMADOR E INTERRUPTOR DE PRESIÓN LEA Y CONSERVE ESTAS INSTRUCCIONES SOLO PARA USO RESIDENCIAL UBICACIÓN DE LA ENTRADA DEL AIRE EXTERIOR El diseño y el sitio adecuados de la ubicación de la entrada de aire exterior son vitales para garantizar que el re...

Page 10: ...ADORES Tal vez se requiera más de un regulador para equilibrar el sistema Si se requiere más de uno use 1 MD6TU o MD8TU y luego use los reguladores MD6 o MD8 como reguladores adicionales INSTALACIÓN DEL INTERRUPTOR DE PRESIÓN Y SONDA Para que la sonda y el interruptor de presión funcionen con eficacia la tapa para techo o pared debe tener un regulador cargado por resorte Se recomiendan los siguien...

Page 11: ... que se abre el regulador Apague la campana y compruebe que se cierra el regulador Un contratista calificado en HVAC también debe asegurarse la operación adecuada y la ventilación de todo el equipo de combustión en la casa Cablee el sistema como se ilustra 24V 20V CONTACTOS DE 24 V CABLEADO DELTRANSFORMADOR DISPARO EN FALSO Bajo ciertas condiciones extremas podría haber el disparo en falso del reg...

Page 12: ...as están diseñadas para extraer contaminantes como olores de cocinado o humedad en la fuente de tal manera que no perduren en la casa Debido a que estos ventiladores extraen el aire de la casa es necesario reemplazar este aire con aire nuevo del exterior Normalmente este aire de repuesto entra a la casa a través de grietas y orificios en la armazón del edificio Pero las casas modernas están mucho ...

Reviews: