background image

7

POSITIONS DE MONTAGE DE LA SONDE ET 

DU MANOCONTACTEUR

MONTAGE DE LA SONDE ET DU 

MANOCONTACTEUR

DÉBIT 

D'AIR

DISPOSITION DU

MANOCONTACTEUR POUR

LES VENTILATEURS

EXTERNE ET EN LIGNE

TUBE CONNECTÉ

À L’ENTRÉE NOIRE (+)

DISPOSITION DU

MANOCONTACTEUR POUR

LES VENTILATEURS

INTERNES

COSSES 

OUVERTES 

DE 1/4 PO

Ouverture 

de la sonde 

tournée vers 

le bas

DÉBIT 

D'AIR

FILS 

DE BASSE 

TENSION

Ouverture 

de la sonde 

tournée vers 

le bas

COSSES 

OUVERTES 

DE 1/4 PO

FILS 

DE BASSE 

TENSION

TUBE CONNECTÉ

À L’ENTRÉE GRIS (-)

CONDUIT 

HORIZONTAL

MANOCONTACTEUR

TUBE

SONDE

 (la flèche 

pointe dans 

le sens du 

débit d’air)

DÉBIT 

D'AIR

CONDUIT

CONDUIT 
VERTICAL

MANOCONTACTEUR

TUBE

SONDE 

(la flèche 

pointe dans 

le sens du 

débit d’air)

DÉBIT 

D'AIR

CONDUIT

MANOCONTACTEUR

TUBE

SONDE 

(la flèche 

pointe dans 

le sens du 

débit d’air)

DÉBIT 

D'AIR

CONDUIT

JOINT

VIS À 

TÔLE

Connecter 

le tube sur 

l’extérieur du 

raccord noir.

Percer un TROU 

de 9,5 mm (3/8 po) 

dans le conduit

CÂBLAGE DU SYSTÈME

NOIR (LIGNE)

BLANC (NEUTRE)

VERT (TERRE)

CLAPET D'AIR DE COMPENSATION

TRANSFORMATEUR

24V

MANOCONTACTEUR

DIAGRAMME DE CÂBLAGE 

UN CLAPET

24V

TESTER LE SYSTÈME

Une fois le clapet, le manocontacteur et la sonde installés, actionnez la hotte à haute vi-

tesse et vérifiez que le clapet s’ouvre. Arrêtez la hotte et vérifiez que le clapet se referme.
Un spécialiste en appareil de chauffage et de climatisation doit également s’assurer du 

bon fonctionnement de tout appareil de combustion, notamment l’évacuation des gaz 

de combustion.

Effectuez le câblage tel qu’illustré.

NOIR (LIGNE)

BLANC (NEUTRE)

VERT (TERRE)

CLAPET D'AIR DE COMPENSATION

TRANSFORMATEUR

24V

MANOCONTACTEUR

DIAGRAMME DE CÂBLAGE

CLAPETS MULTIPLES

CLAPET D'AIR DE COMPENSATION

24V

24V

24V

24V

20V

BORNES 24V

CÂBLAGE DU TRANSFORMATEUR

DÉCLENCHEMENT INDÉSIRABLE 

Dans certaines conditions extrêmes, le clapet peut se déclencher alors qu’il ne le devrait 

pas (s’ouvre alors que la hotte est arrêtée). Si un tel déclenchement indésirable se 

produit, placez un clapet refoulement intermédiaire [modèle de 17,8 cm (7 po) n° 97, 

modèle de 20,3 cm (8 po) n° 438, modèle de 25,4 cm (10 po) n° 421] entre la sonde et 

le capuchon mural ou de toit.

LISTE DES PIÈCES DE RECHANGE

97018853     Ensemble de manocontacteur
97013273     Transformateur 24 V
99527207     Clapet motorisé de 15,2 cm (6 po)
99527208     Clapet motorisé de 20,3 cm (8 po)
99528460     Clapet motorisé de 25,4 cm (10 po)

CÂBLAGE DU SYSTÈME (a continué)

Un entretien régulier est nécessaire pour garantir le bon fonctionnement du système de 

clapet. Toute négligence à cet égard risque d’affecter la capacité du clapet d’introduire 

de l’air frais dans l’habitation. Cet entretien régulier doit comporter les points suivants :
•  Nettoyer l’extérieur du grillage aviaire de la prise d’air pour éviter que des débris 

empêchent l’arrivée de l’air frais.

•  Nettoyer ou remplacer le(s) filtre(s) d’air frais avant l’entrée de l’air dans la maison.
•  Veiller à ce que l’ouverture du capuchon mural extérieur reste dégagée : déblayer la 

neige, enlever les feuilles ou la végétation autour du capuchon.

•  Lors de la visite d’entretien régulière du spécialiste du chauffage, demandez-lui de 

vérifier le bon fonctionnement du clapet.

ENTRETIEN

Summary of Contents for MD10TU

Page 1: ...Insulate the duct and damper to prevent build up of condensation in cold weather climates Vapor barriers on both sides of insulation are recommended PLAN THE INSTALLATION Planning the installation first requires selecting the most appropriate installation ap proach The chart below offers suggestions for the most effective installation approach by considering a few important factors Further details...

Page 2: ...re It may not operate at low speeds since the pressure is below this limit MULTIPLE DAMPERS More than one damper may be required to balance the system If more than one is required use 1 MD6TU or MD8TU and then use the MD6 or MD8 dampers as ad ditional dampers INSTALLATION OF PRESSURE SWITCH AND PROBE For the probe pressure switch to work effectively the roof or wall cap must have a spring loaded d...

Page 3: ...ion and venting of all combustion equipment in the home FALSE TRIPPING Under certain extreme conditions there could be false tripping of the damper opening when the range hood blower is off If false tripping is encountered place an in line backdraft damper 7 model no 97 8 model no 438 10 model no 421 between the probe and the roof or wall cap SERVICE PARTS 97018853 Pressure Switch Kit 97013273 24V...

Page 4: ... the home by a range hood Range hoods are designed to pull out pollutants like cooking odors or moisture at the source so they don t linger in the home Because these fans pull air out of the house this air needs to be replaced with new air from outdoors Normally this make up air enters the home through cracks and holes in the shell of the building But modern homes are air sealed much more thorough...

Page 5: ...SERVER POUR USAGE RÉSIDENTIEL SEULEMENT MODÈLES MD6TU MD8TU MD10TU EMPLACEMENT DE LA PRISE D AIR EXTÉRIEUR La conception et l emplacement adéquats de la prise d air extérieur sont indispensables au bon fonctionnement et à la fiabilité du clapet pour faire pénétrer de l air frais dans la maison Il importe de respecter les exigences suivantes lors du positionnement de la prise d air La prise d air e...

Page 6: ...me Si vous utilisez plusieurs clapets choisissez un 1 clapet MD6TU ou MD8TU puis utilisez les modèles MD6 ou MD8 comme clapets additionnels INSTALLATION DU MANOCONTACTEUR ET DE LA SONDE Pour que la sonde et le manocontacteur fonctionnent correctement le capuchon mural ou de toit doit avoir un clapet à ressort Les produits Broan suivants sont recommandés MODÈLES DE CAPUCHON DE TOIT 437 Haute capaci...

Page 7: ...stion Effectuez le câblage tel qu illustré NOIR LIGNE BLANC NEUTRE VERT TERRE CLAPET D AIR DE COMPENSATION TRANSFORMATEUR 24V MANOCONTACTEUR DIAGRAMME DE CÂBLAGE CLAPETS MULTIPLES CLAPET D AIR DE COMPENSATION 24V 24V 24V 24V 20V BORNES 24V CÂBLAGE DUTRANSFORMATEUR DÉCLENCHEMENT INDÉSIRABLE Dans certaines conditions extrêmes le clapet peut se déclencher alors qu il ne le devrait pas s ouvre alors q...

Page 8: ...e stagnent pas dans la maison Puisque ces ventilateurs évacuent l air de la maison celui ci doit être remplacé par de l air neuf de l extérieur Normalement cet air de compensation entre dans l habitation par les ouvertures et les fentes de l enveloppe de l édifice Or les maisons modernes sont beaucoup plus étanches et ne présentent plus autant de fentes et d ouvertures De plus certains ventilateur...

Page 9: ...our éviter la condensation Il est conseillé de placer un coupe vapeur des deux côtés de l isolant REGULADOR DE AIRE AUTOMÁTICO DE REPUESTO CON TRANSFORMADOR E INTERRUPTOR DE PRESIÓN LEA Y CONSERVE ESTAS INSTRUCCIONES SOLO PARA USO RESIDENCIAL UBICACIÓN DE LA ENTRADA DEL AIRE EXTERIOR El diseño y el sitio adecuados de la ubicación de la entrada de aire exterior son vitales para garantizar que el re...

Page 10: ...ADORES Tal vez se requiera más de un regulador para equilibrar el sistema Si se requiere más de uno use 1 MD6TU o MD8TU y luego use los reguladores MD6 o MD8 como reguladores adicionales INSTALACIÓN DEL INTERRUPTOR DE PRESIÓN Y SONDA Para que la sonda y el interruptor de presión funcionen con eficacia la tapa para techo o pared debe tener un regulador cargado por resorte Se recomiendan los siguien...

Page 11: ... que se abre el regulador Apague la campana y compruebe que se cierra el regulador Un contratista calificado en HVAC también debe asegurarse la operación adecuada y la ventilación de todo el equipo de combustión en la casa Cablee el sistema como se ilustra 24V 20V CONTACTOS DE 24 V CABLEADO DELTRANSFORMADOR DISPARO EN FALSO Bajo ciertas condiciones extremas podría haber el disparo en falso del reg...

Page 12: ...as están diseñadas para extraer contaminantes como olores de cocinado o humedad en la fuente de tal manera que no perduren en la casa Debido a que estos ventiladores extraen el aire de la casa es necesario reemplazar este aire con aire nuevo del exterior Normalmente este aire de repuesto entra a la casa a través de grietas y orificios en la armazón del edificio Pero las casas modernas están mucho ...