background image

MODELS   355CSOBK • 355CSOBR

Page 1

WARNING  

  

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY 

TO PERSONS, OBSERVE THE FOLLOWING:

1.  Use this unit only in the manner intended by the manufacturer. 

If you have questions, contact the manufacturer at the address 

or telephone number listed in the warranty.

2.  Before servicing or cleaning unit, disable the ventilator by cover-

ing the solar panel with cardboard or disconnecting the wires 

from the motor terminals (note wire locations when disconnect-

ing).

3.  Installation work must be done by a qualified person(s) in ac-

cordance with all applicable codes and standards, including 

fire-rated construction codes and standards.

4.  If removing an existing 120 VAC powered attic ventilator, use 

only  a  qualified  person(s)  to  remove  any  electrical  wiring  in 

accordance with all applicable codes and standards.

5.  Sufficient air is needed for proper combustion and exhausting 

of gases through the flue (chimney) of fuel burning equipment 

to prevent backdrafting. Follow the heating equipment manufac-

turer's guidelines and safety standards such as those published 

by  the  National  Fire  Protection Association  (NFPA),  and  the 

American Society for Heating, Refrigeration and Air Condition-

ing Engineers (ASHRAE), and the local code authorities.

6.  When  cutting  or  drilling  into  wall  or  ceiling,  do  not  damage 

electrical wiring and other hidden utilities.

CAUTION  

1.  For general ventilating use only. Do not use to exhaust hazard-

ous or explosive materials and vapors.

2.  To avoid motor bearing damage and noisy and/or unbalanced 

impellers, keep drywall spray, construction dust, etc. off power 

unit.

3.  This unit has an unguarded impeller. Do not use in locations 

readily accessible to people or animals.

4.  This ventilator operates when the solar panel is exposed to 

sun light.  To reduce risk of injury while installing, servicing or 

cleaning unit, cover the solar panel with cardboard or discon-

nect the wires from the motor terminals (note wire locations 

when disconnecting).

5.  The  recommended  open  air  inlet  for  this  ventilator  is  4.25 

square feet. The best location for these air intake vents are 

under the eaves with direct access to the attic. Failure to pro-

vide these intakes could cause natural-draft gas appliances to 

backdraft.

6.  Your attic fan installation will create a screened opening into 

your attic space. During a heavy rain storm there could be a 

light spray of rain into this attic space. This is a normal condi-

tion with all attic ventilators and will not cause any damage to 

the structure. We recommend that you do not store any valu-

able articles directly under the fan opening in the roof. 

7.  This ventilator is intended for roof installation. Broan Models 

353  &  353SOBK  Gable  Mount  Ventilators  are  available  for 

side wall applications.

8.  The  plastic  ventilator  dome  and  base  may  be  painted  with 

high quality paint. Follow the paint manufacturer's recommen-

dations for acrylic and ABS plastic as appropriate.  Take care 

to avoid getting paint on the solar panel.

9.  Please read specification label on product for further informa-

tion and requirements.

10. The  installation  instructions  contained  in  this  document  are 

only  a  recommendation  and  individual  professionals  may 

have  their  own  methods  of  installation.    If  your  roof  has  an 

existing warranty, installation of this product by anyone other 

than those who installed the roof may jeopardize any future 

warranty claim.  Please check with the original installer of your 

roof if this is a concern. 

ROOF-MOUNT CURB

SOLAR POWERED 

ATTIC VENTILATOR

READ AND SAVE THESE INSTRUCTIONS

Drill

1/4" Drill Bit

Sabre Saw or Keyhole Saw

Hammer

Ruler / Tape Measure

Pencil, Marker or Scribe

Utility Knife

Pry Bar (to remove roofing nails)

5/16" Socket and Extension

Roofing Cement

Galvanized Roofing Nails (1¾" min.)

TOOLS AND MATERIALS REQUIRED

Register your product online at:

www.broan.com/register

Summary of Contents for ROOF-MOUNT CURB SOLAR POWERED ATTIC VENTILATOR 355CSOBK

Page 1: ... cleaning unit cover the solar panel with cardboard or discon nect the wires from the motor terminals note wire locations when disconnecting 5 The recommended open air inlet for this ventilator is 4 25 square feet The best location for these air intake vents are under the eaves with direct access to the attic Failure to pro vide these intakes could cause natural draft gas appliances to backdraft 6...

Page 2: ...erally we recommend a point located 24 36 on center below the roof peak and centrally along the ridgeline on the south southwest or west side of the home 2 Prior to installation we recommend setting up the ventilator to verify operation Take the ventilator to a location exposed to sun Removing the cardboard cover from the solar panel should cause the ventilator to operate Secure cardboard in place...

Page 3: ...nt use a nail and string to scribe a 14 diameter circle on the black paper or roof decking 6 Taking into consideration the thickness of your chosen flashing material build a 19 1 4 x 16 1 8 outside dimensions curb out of 2 x 4 or 2 x 6 material 20 17 7 Working from the outside of your roof use the guide hole as a center point cut and remove roofing material in a 20 x 17 minimum area 19 1 4 2 MIN 1...

Page 4: ...ith the roof ridge and toenail in place Make sure the curb is securely attached to the roof 12 Flash with lead copper or other preferred flashing materials Ensure flashing on top two thirds of curb is installed under adjacent roofing materials 13 Apply a large bead of silicone on the bottom side of ventilator base place over curb and affix with galvanized nails or screws 14 Using a good grade of r...

Page 5: ...lack Brown 1 S99527247 S99527248 Solar Panel Assembly Dome 2 S99527261 S99527261 Fan Blade w Set Screw 3 S99527257 S99527257 Motor DC 4 S99527253 S99527254 Roof Sheet Panel Curb 1 2 3 4 SERVICE PARTS Replacement parts can now be ordered on our website Please visit us at www Broan com ...

Page 6: ...provision herein to the contrary this Warranty shall not extend or obligate Broan to take any action with respect to A Products which have been modified altered installed used or operated in a manner which is not recommended by Broan including any Products in which parts not manufactured or approved by Broan have been installed B Products which have not been regularly or properly serviced in accor...

Page 7: ...re est exposé au soleil Pour réduire les risques de blessure lors de l installation de l entretien ou du nettoyage de l appareil couvrez le panneau solaire d un carton ou débranchez les fils des bornes du moteur notez leur position en les débranchant 5 L entrée d air recommandée pour ce ventilateur est de 0 40 m2 4 25 pi2 Le meilleur emplacement de ces entrées d air est sous les avant toit accédan...

Page 8: ...nérale nous recommandons un point situé à environ 61 à 91 cm 24 à 36 po au centre en dessous du faîte du toit et centré sur le pan sud sud ouest ou ouest du toit 2 Avant l installation il est conseillé d essayer le ventilateur pour vérifier son fonctionnement Placez le ventilateur à un endroit exposé au soleil Enlever le carton qui couvre le panneau solaire devrait faire démarrer le ventilateur Fi...

Page 9: ...z un cercle de 35 6 cm 14 po de diamètre sur le papier noir ou le panneau du toit 6 En tenant compte de l épaisseur du solin utilisé fabriquez un cadre de 49 x 41 cm 19 1 4 x 16 1 8 po dimensions extérieures à l aide de 5 x 10 cm po ou de 5 x 15 cm 2 x 4 po ou de 2 x 6 po 20 17 7 En travaillant du côté extérieur du toit et en utilisant l avant trou comme point central découpez et enlevez le revête...

Page 10: ... et clouez le en place Assurez vous que le cadre est solidement fixé au toit 12 Installez un solin de plomb de cuivre ou du matériau choisi Assurez vous que le solin des deux tiers supérieurs du cadre est bien glissé sous le revêtement adjacent du toit 13 Appliquez un gros cordon de silicone sur le dessous de la base du ventilateur placez le sur le cadre et fixez le avec des clous galvanisés ou de...

Page 11: ...sur notre site Web Visitez notre site à www Broan com Repère Modèle 355CSOBK noir Modèle 355CSOBR brun Description 1 S99527247 S99527248 Ensemble de panneau solaire dôme 2 S99527261 S99527261 Hélice de ventilateur avec vis d arrêt 3 S99527257 S99527257 Moteur CC 4 S99527253 S99527254 Panneau de toiture cadre ...

Page 12: ...rait obliger Broan à prendre des dispositions en ce qui a trait à A des produits ayant été modifiés altérés installés utilisés ou ayant servi d une manière non recommandée par Broan y compris tout produit dans lequel des pièces qui n ont pas été fabriquées ou approuvées par Broan ont été installées B des produits qui n ont pas été régulièrement ou adéquatement entretenus conformément au Manuel de ...

Page 13: ...Este ventilador se acciona cuando el panel solar se expone a la luz del sol Para reducir el riesgo de lesiones mientras instala da servicio o limpia la unidad cubra el panel solar con cartón o desconecte los cables de las terminales del motor tome nota de las ubicaciones de los cables cuando los desconecte 5 La entrada de aire abierta recomendada para este ventilador es de 4 25 pies cuadrados 0 4 ...

Page 14: ...comendamos un punto situado de 24 a 36 pulg 61 a 91 cm por debajo del punto más alto del techo y centrado a lo largo de la línea del reborde sobre el lado sur suroeste u oeste de la casa 2 Antes de realizar la instalación recomendamos configurar el ventilador para verificar el funcionamiento Lleve el ventilador a un sitio expuesto al sol Quitar la cubierta de cartón del panel solar debe hacer que ...

Page 15: ...lg 35 6 cm de diámetro sobre el papel negro o la cubierta del techo 6 Tomando en cuenta el espesor del material del cubrejuntas que haya elegido forme un bordillo de 19 1 4 x 16 1 8 pulg 49 x 41 cm dimensiones exteriores con material de 2 x 4 pulg o de 2 x 6 pulg 5 x 10 cm o 5 x 15 cm 20 17 7 Trabajando desde el exterior del techo utilice el orificio guía como punto central corte y quite el materi...

Page 16: ...avo oblicuo en su lugar Asegúrese de que el bordillo esté firmemente sujeto al techo 12 Aplique el cubrejuntas con plomo cobre u otros materiales preferidos para este propósito Asegúrese de instalar el cubrejuntas en los dos tercios superiores del bordillo debajo de los materiales del techo adyacentes 13 Aplique un cordón grande de silicona por el lado inferior de la base del ventilador coloque so...

Page 17: ...en nuestro sitio Web Visítenos en www Broan com Clave N o Modelo 355CSOBK negro Modelo 355CSOBR café Descripción 1 S99527247 S99527248 Conjunto del panel solar domo 2 S99527261 S99527261 Aspa del ventilador con tornillo de fijación 3 S99527257 S99527257 Motor CC 4 S99527253 S99527254 Panel en lámina para el techo Bordillo ...

Page 18: ...n en la presente que señale otra cosa esta Garantía no se ampliará para Broan ni la obligará a tomar medida alguna con respecto a A Productos que hayan sido modificados alterados instalados usados u operados de una manera que no sea recomendada por Broan incluyendo cualesquiera Productos en los cuales se hayan instalado piezas no fabricadas ni aprobadas por Broan B Productos que no hayan recibido ...

Page 19: ...MODELOS 355CSOBK 355CSOBR Página 19 ...

Page 20: ...MODELOS 355CSOBK 355CSOBR Página 20 99527269A ...

Reviews: