background image

MODELS

S50U, S80U, S80UE,

S110U & S110UE

TYPICAL INSTALLATION

INSTALLER:  LEAVE THIS MANUAL WITH THE HOMEOWNER.

HOMEOWNER:  USE AND CARE INSTRUCTIONS ON PAGE 3.

SOLITAIRE ULTRA-SILENT

®

 FAN

READ  AND  SAVE  THESE  INSTRUCTIONS

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY
TO PERSONS, OBSERVE THE FOLLOWING:

1. Use this unit only in the manner intended by the manufacturer. If

you have questions, contact the manufacturer at the address or
telephone number listed in the warranty.

2. Before servicing or cleaning unit, switch power off at service panel

and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.

3. Installation work and electrical wiring must be done by a qualified

person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.

4. Sufficient air is needed for proper combustion and exhausting of

gases through the flue (chimney) of fuel burning equipment to
prevent backdrafting. Follow the heating equipment manufacturer’s
guideline and safety standards such as those published by the
National Fire Protection Association (NFPA), and the American
Society for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.

5. When cutting or drilling into wall or ceiling, do not damage electrical

wiring and other hidden utilities.

6. Ducted fans must always be vented to the outdoors.

7. If this unit is to be installed over a tub or shower, it must be marked

as appropriate for the application and be connected to a GFCI
(Ground Fault Circuit Interrupter) - protected branch circuit.

8. Never place a switch where it can be reached from a tub or shower.

9. This unit may be used over a tub or shower enclosure when

installed in a GFCI protected branch circuit. (Ceiling Installation
only)

10. This unit must be grounded.

CAUTION

1. For general ventilating use only. Do not use to exhaust hazardous

or explosive materials and vapors.

2. To avoid motor bearing damage and noisy and/or unbalanced

impellers, keep drywall spray, construction dust, etc. off power
unit.

3. Please read specification label on product for further information

and requirements

.

HOUSING

MOUNTING

BRACKET

CEILING

JOIST

POWER

CABLE

GRILLE

FINISHED CEILING

4" ROUND

DAMPER/DUCT

CONNECTOR

This unit can be installed anywhere between joists using mounting
brackets provided.

The unit can be
installed in a
suspended ceiling
using wire as
shown.

The unit will operate
most quietly when
located where the
shortest possible
duct run and
minimum number of
elbows will be
needed.

Plan to supply the
unit with proper line voltage and appropriate power cable.

Follow these basic steps when installing this unit:

• Nail housing to joists.
• Attach ductwork.
• Connect power cable.
• Install blower assembly.
• Fasten grille to housing.

POWER

CABLE

SUSPENDED CEILING

MATERIAL

4" ROUND DUCT

HOUSING

Reviews: