MODEL   QTR070

WARNING  

  

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-

JURY TO PERSONS, OBSERVE THE FOLLOWING:

1.  Use this unit only in the manner intended by the manufacturer. 

If you have questions, contact the manufacturer at the address 

or telephone number listed in the warranty.

2.  Before servicing or cleaning unit, switch power off at service 

panel and lock the service disconnecting means to prevent 

power  from  being  switched  on  accidentally.  When  the  ser-

vice disconnecting means cannot be locked, securely fasten 

a  prominent  warning  device,  such  as  a  tag,  to  the  service 

panel.

3.  Installation  work  and  electrical  wiring  must  be  done  by  a 

qualified  person(s)  in  accordance  with  all  applicable  codes 

and  standards,  including  fire-rated  construction  codes  and 

standards.

4.  Sufficient air is needed for proper combustion and exhausting 

of  gases  through  the  flue  (chimney)  of  fuel  burning  equip

-

ment to prevent backdrafting. Follow the heating equipment 

manufacturer’s guideline and safety standards such as those 

published by the National Fire Protection Association (NFPA), 

and the American Society for Heating, Refrigeration and Air 

Conditioning Engineers (ASHRAE), and the local code authori

-

ties.

5.  When cutting or drilling into wall or ceiling, do not damage 

electrical wiring and other hidden utilities.

6.  Ducted fans must always be vented to the outdoors.
7.  Acceptable for use over a tub or shower when connected to 

a GFCI (Ground Fault Circuit Interrupter) - protected branch 

circuit (ceiling installation only).

8.  This unit must be grounded.

CAUTION  

1.  For general ventilating use only. Do not use to exhaust hazard

-

ous or explosive materials and vapors.

2.  This  product  is  designed  for  installation  in  ceilings  up  to  a 

12/12 pitch (45 degree angle). Duct connector must point up. 

DO NOT MOUNT THIS PRODUCT IN A WALL.

3.  To avoid motor bearing damage and noisy and/or unbalanced 

impellers, keep drywall spray, construction dust, etc. off power 

unit.

4.  Please read specification label on product for further informa

-

tion and requirements.

MODEL QTR070
ULTRA SILENT

 

TM

 FAN

READ AND SAVE THESE INSTRUCTIONS

WARRANTY

Installer: Leave this manual with the homeowner.

OPERATION

Use an on/off switch or speed control to operate this ventilator. 

See “Connect Wiring” for details.

BROAN-NUTONE THREE YEAR LIMITED WARRANTY

Broan-NuTone warrants to the original consumer purchaser of its products 

that such products will be free from defects in materials or workmanship 

for a period of three years from the date of original purchase. THERE ARE 

NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT 

NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR 

FITNESS FOR A PARTICULAR PURPOSE.

During this three-year period, Broan-NuTone will, at its option, repair or 

replace, without charge, any product or part which is found to be defective 

under normal use and service.

THIS  WARRANTY  DOES  NOT  EXTEND  TO  FLUORESCENT  LAMP 

STARTERS  AND  TUBES.  This  warranty  does  not  cover  (a)  normal 

maintenance and service or (b) any products or parts which have been 

subject to misuse, negligence, accident, improper maintenance or repair 

(other than by Broan-NuTone), faulty installation or installation contrary to 

recommended installation instructions.

The duration of an implied warranty is limited to the three-year period as 

specified for the express warranty. Some states do not allow limitation 

on how long an implied warranty lasts, so the above limitation may not 

apply to you.

BROAN-NUTONE’S  OBLIGATION  TO  REPAIR  OR  REPLACE,  AT 

BROAN-NUTONE’S  OPTION,  SHALL  BE  THE  PURCHASER’S  SOLE 

AND  EXCLUSIVE  REMEDY  UNDER  THIS  WARRANTY.  BROAN-NU-

TONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL 

OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH 

PRODUCT USE OR PERFORMANCE. Some states do not allow the ex

-

clusion or limitation of incidental or consequential damages, so the above 

limitation may not apply to you.

This warranty gives you specific legal rights, and you may also have other 

rights, which vary from state to state. This warranty supersedes all prior 

warranties.

To qualify for warranty service, you must (a) notify Broan-NuTone at the 

address or telephone number stated below, (b) give the model number and 

part identification and (c) describe the nature of any defect in the product or 

part. At the time of requesting warranty service, you must present evidence 

of the original purchase date.

Broan-NuTone LLC    Hartford, Wisconsin 

www.broan.com    800-558-1711

To register this product visit:

www.broan.com

CLEANING & MAINTENANCE

For quiet and efficient operation, long life, and attractive appear

-

ance - lower or remove grille and vacuum interior of unit with the 

dusting brush attachment.
The motor is permanently lubricated and never needs oiling. If the 

motor bearings are making excessive or unusual noises, replace 

the blower assembly (includes motor and impeller).

Summary of Contents for ULTRA SILENT QTR070

Page 1: ...uTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of three years from the date of original purchase THERE ARE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE During this three year period Broan NuTone wil...

Page 2: ...ible duct run and minimum number of elbows will be needed Use a roof cap or wall cap that has a built in damper to reduce backdrafts Plan to supply the unit with proper line voltage and appropriate power cable Cooking Equipment Floor COOKING AREA Do not install above or inside this area 45o 45o NOT FOR USE IN A COOKING AREA ROOF CAP 4 in ROUND ELBOW S 4 in ROUND DUCT WALL CAP Purchase separately i...

Page 3: ...amper duct connector Run ductwork to a roof cap or wall cap Tape all ductwork con nections to make them secure and air tight INSTALL HOUSING DUCT 1 Bend housing tabs Use a pliers to bend housing TABS out to 900 2 Mount housing to joist Hold housing in place so that the housing tabs contact the bottom of the joist The hous ing mounts with four 4 screws or nails Screw or nail housing to joist throug...

Page 4: ...ueeze grille springs and insert them into slots on each side of hous ing 8 Push grille against ceiling 6 Finish ceiling Install ceiling material Cut out around housing Order service parts by Part No not by Key No Replacement parts can be ordered on our web site Please visit us at www broan com SERVICE NOTE To remove Blower Assembly Unplug motor Remove thumbscrew 10 from motor plate flange Find the...

Page 5: ...nterruptor de encendido apagado o control de velocidad Vea los detalles en la sección Conexión eléctrica VENTILADOR ULTRA SILENCIOSO MODELO QTR070 GARANTÍA LIMITADA DE TRES AÑOS DE BROAN NUTONE Broan NuTone garantiza al consumidor comprador original que sus produc tos estarán libres de defectos en cuanto a material y mano de obra durante un período de tres años a partir de la fecha de la compra or...

Page 6: ...o posible y un mínimo número de codos Instale una tapa de techo o de pared que tenga un regulador de tiro incorporado a fin de reducir los contratiros Alimente la unidad con el voltaje de línea y el cable eléctrico apropiados Equipo para cocinar Piso ÁREA QUE COCINA No instale sobre o dentro de esta área 45o 45o NO PARA EL USO EN UN ÁREA QUE COCINA CODO REDONDO DE 4 PULG Cubierta de ventilador CON...

Page 7: ...lador caiga cerrada 4 Instale el conducto redondo de 4 pulgadas Conecte el con ducto redondo de 4 pulgadas al conec tor del regulador conducto Extienda el conducto hacia una tapa de techo o tapa de pared Encinte todas las conexiones de los conductos para fijarlas y hacerlas herméticas al aire 2 Monte la cubierta en la vigueta Sostenga la cubi erta en su lugar de manera que las lengüetas de la cubi...

Page 8: ...o de la cubierta 8 Empuje la rejilla contra el cielo raso 6 Termine el cielo raso Instale el material del cielo raso Recorte alrededor de la cubierta Al hacer el pedido de una pieza de servicio se debe especificar el número de la pieza no el número de la clave NOTA DE SERVICIO Para desmontar el conjunto del ventilador Desenchufe el motor Saque el tornillo de mariposa 10 de la brida de la placa del...

Reviews: