HOUSING

MOUNTING

BRACKET

CEILING

JOIST

POWER

CABLE

GRILLE

FINISHED CEILING

4" ROUND

DAMPER/DUCT

CONNECTOR

MODELS

S80LU & S110LU

TYPICAL INSTALLATION

INSTALLER:  LEAVE THIS MANUAL WITH THE HOMEOWNER.

HOMEOWNER:  USE AND CARE INSTRUCTIONS ON PAGE 3.

SOLITAIRE ULTRA-SILENT

®

FAN / LIGHT / NIGHT LIGHT

READ  AND  SAVE  THESE  INSTRUCTIONS

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING:

1. Use this unit only in the manner intended by the manufacturer. If you

have questions, contact the manufacturer at the address or telephone
number listed in the warranty.

2. Before servicing or cleaning unit, switch power off at service panel and

lock the service disconnecting means to prevent power from being
switched on accidentally. When the service disconnecting means
cannot be locked, securely fasten a prominent warning device, such
as a tag, to the service panel.

3. Installation work and electrical wiring must be done by a qualified

person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.

4. Sufficient air is needed for proper combustion and exhausting of gases

through the flue (chimney) of fuel burning equipment to prevent
backdrafting. Follow the heating equipment manufacturer’s guideline
and safety standards such as those published by the National Fire
Protection Association (NFPA), and the American Society for Heating,
Refrigeration and Air Conditioning Engineers (ASHRAE), and the local
code authorities.

WARNING

5. When cutting or drilling into wall or ceiling, do not damage electrical

wiring and other hidden utilities.

6. Ducted fans must always be vented to the outdoors.

7. If this unit is to be installed over a tub or shower, it must be marked

as appropriate for the application and be connected to a GFCI (Ground
Fault Circuit Interrupter) - protected branch circuit.

8. Never place a switch where it can be reached from a tub or shower.

9. This unit must be grounded.

CAUTION

1. For general ventilating use only. Do not use to exhaust hazardous or

explosive materials and vapors.

2. This product is designed for ceiling installation only. This product is

designed for installation in ceilings up to a 7/12 pitch. Ductwork must
point up. DO NOT MOUNT THIS PRODUCT IN A WALL.

3. To avoid motor bearing damage and noisy and/or unbalanced

impellers, keep drywall spray, construction dust, etc. off power unit.

4. Please read specification label on product for further information and

requirements

.

This unit can be installed anywhere between joists using mounting
brackets provided.

The unit can be
installed in a
suspended ceiling
using wire as shown.

The unit will operate
most quietly when
located where the
shortest possible
duct run and
minimum number of
elbows will be
needed.

Plan to supply the
unit with proper line
voltage and appropriate power cable.

Follow these basic steps when installing this unit:

• Nail housing to joists.
• Attach ductwork.
• Connect power cable.
• Install blower assembly.
• Fasten grille to housing.

POWER 

CABLE

SUS

PEND

ED CE

ILING

 

MATER

IAL

4" RO

UND

 

DUCT

HOUSING