CAUTION
Failure to comply with the following can cause erratic operation of the control and/or unit:
• Never install more than one main wall control per ventilation unit.
• Keep control low voltage wiring at least 1 foot (305 mm) away from motors, lighting balast, light dimming circuit
and power distribution panel. Do not route control wiring alongside house power wiring.
• Ensure the wires are securely connected.
Unplug the ventilation unit.
VC0255
Using the mounting plate, mark the
hole opening and screw locations at
the desired height on the wall.
VC0217
VC0219
Unscrew the screw located on the
underside of the wall control.
Separate the front module from the
mounting plate by lifting its bottom
part.
VC0244A
Ø 3/16", typ.
Cut the hole opening using the mark
previously drawn (1/8
"
outside the
mark is recommended). Drill both
screw holes (3/16" Ø) in wall and insert
the wall anchors (included).
Fix the mounting plate to the wall using the screws provided.
12V D- D+ Gnd
Strip the end of the cable to access
the 4 wires (about 3
"
). Strip the end of
each wire (about 1/4
"
). Connect the
wires to the terminals, regardless of
the wire color. Note which wire color
has been chosen for each terminal.
VC0218
Install the front module on the
mounting plate. Fix both parts by
screwing the screw on the underside
of the wall control.
Be careful not to pinch wires when reinstalling the front
module on the mounting plate.
CAUTION
Plug the ventilation unit in power source.
I
NSTALLATION
AND
U
SER
G
UIDE
FOR
A
DVANCED
T
OUCHSCREEN
C
ONTROL
The illustrations in this document are generic; your control appearance may be slightly different from the ones shown.
Electrical wiring must be done by qualifi ed personnel in accordance with all applicable codes and standards.
Before connecting wires, unplug the unit or switch power off at service panel and lock service disconnecting means
to prevent power from being switched on accidentally. Always wear safety glasses and gloves while performing
these instructions.
WARNING
!
This control is compatible with all AI series units.
23839 rev. 03
Perform the electrical connection to the terminal connector
of the unit, as shown below. For more details, refer to the
installation manual of the ventilation unit.
12V D- D+ Gnd
VC0232
NOTE: To avoid miswiring, refer to the notes taken at step
to match the wire color with the right terminal.
W
ALL
CONTROL
REAR
VIEW
READ AND SAVE THESE INSTRUCTIONS
NOTE: If the control is to be installed in an electric box, do
not perform steps 3 and 4.
If ducts have to go through an unconditioned space (e.g.: attic), always use insulated ducts to prevent condensation
formation inside and outside ducts, which could cause material damage and/or mold growth. Moreover, if fresh air
to building duct and/or stale air from building duct goes/go through an unconditioned space, the unit must be set
to operate continuously in cold conditions (below 10°C/50°F). Continuous air movement inside ducts will prevent
condensation formation. The unit can be stopped temporarily for maintenance and/or repair purposes in such
conditions. (Refer to section 2.2 from unit User and Installer Manual for more details.)
CAUTION