3-10
6. Disconnect probe wires.
Note:
Be sure red and yellow wires are not
reversed during replacement. Controller will
display PROB if polarity is reversed.
7. Disconnect transformer wires within
wire nuts.
8. Remove controller.
9. Assemble in reverse order.
10. See CALIBRATION.
TEMPERATURE SENSOR PROBE
This probe is a thermocouple. It sends fluc-
tuating millivolts to the controller which is
translated into degrees of temperature.
Replacement 2400GH:
1. See ACCESS FOR SERVICE.
2. Disconnect probe (23) wires.
3. OPEN cover. Drain cooking oil from
cooking well. Close drain valve.
4. Remove capillary guard (18) inside of
cooking well.
5. Loosen compression nut (25).
6. Remove fitting (26) from reducer fitting
(20).
7. Remove reducer fitting (20) from out-
side cooking well.
8. Carefully pull probe (24) out of cooking
well.
9. Install new probe in the same location
as old probe.
10. Use teflon tape on reducer fitting (20)
and tighten securely. Install new fitting
(26) into reducer fitting (20) using teflon
tape.
broaster.com Manual #15460 8/02 Rev 7/14
Summary of Contents for 2004E
Page 2: ......
Page 8: ......
Page 12: ......
Page 21: ...2 9 MODEL 2400GH DOMESTIC MODEL 2400GHXP EXPORT broaster com Manual 15460 8 02 Rev 7 14 ...
Page 22: ...2 10 MODEL 2400GHCE EU broaster com Manual 15460 8 02 Rev 7 14 1 2 2 1 2 1 ...
Page 44: ......
Page 45: ...5 COVER YOKE AND LIFT 5 1 FAMILIARIZATION broaster com Manual 15460 8 02 Rev 9 14 ...
Page 54: ......
Page 81: ...9 9 This page intentionally left blank broaster com Manual 15460 8 02 Rev 3 16 ...
Page 87: ...broaster com Manual 15460 8 02 SERVICE NOTES ...
Page 88: ...broaster com Manual 15460 8 02 SERVICE NOTES ...
Page 89: ...broaster com Manual 15460 8 02 SERVICE NOTES ...
Page 90: ......
Page 91: ......
Page 92: ...Broaster Company 2855 Cranston Road Beloit WI 53511 3991 608 365 0193 broaster com ...