4-3
TRANSFORMER (2400GH)
(This transformer not part of fryers manu-
factured for the European Union)
The transformer (12) supplies power to the
gas control valve.
1. See ACCESS FOR SEVICE.
2. Disconnect one wire from the primary
(black and white wires) side and sec-
ondary (yellow and blue wires) side of
the transformer.
3. Check between the two primary wires
with an ohmmeter. Meter should indi-
cate a closed circuit, If not, trans-
former is faulty.
4. Check between the two secondary
wires with an ohmmeter. Meter should
indicate a closed circuit. If not, trans-
former is faulty.
2400GH Pressure Fryer:
broaster.com Manual #17280 1/15 Rev 6/15
Summary of Contents for 2400 Series