6 - PRESSURE SYSTEM
6-1
DO NOT attempt to
tighten, repair, or replace
any fitting, line or component unless
main electric power is disconnected,
pressure regulating valve is OPEN and
cooking oil has cooled. Hot oil could
spray out under pressure causing seri-
ous burns.
The following operator habits may cause
the pressure system to become faulty:
•
Overfilling cooking well with oil: See
operation manual for correct oil level.
•
Overloading basket with product: Oil
level will raise too high.
•
Breading then dropping: Excess coat-
ing can collect in pressure regulating
valve and exhaust tank. See operation
manual for coating instructions.
•
Opening pressure regulating valve
quickly at the end of a cooking cycle:
Excess coating can collect in pressure
regulating valve and exhaust tank.