8-6
Pump Cleaning:
Cleaning will be necessary if pump is seized
and tripping thermal overload on the motor.
1. See PUMP Removal. Remove pump.
2. Remove four bolts (19) and cover (20).
3. Remove interior gears.
4. Clean gears and covers.
5. Replace O-ring and shaft seal if neces-
sary.
6. Install in reverse order using #15820
Primer & #15359 Sealant on pipe
threads.
Reassembly Hints:
1. Pour olive oil or cooking oil on gears
and inside front cover bearing where
gear shaft is installed. Turn gears by
hand for good oil coverage.
2. Be sure cover O-ring is in place before
tightening bolts.