9-6
Frozen IQF Chicken:
COMPLAINT
CAUSE
REMEDY
Product too light
1. Low oil temperature
2. Not done
3. Food basket overloaded
1. Check cook temperature
2. Increase cook time
3. Decrease load
Product too dark
1. High oil temperature
2. Overcooked
3. Oil old
4. Thawed and refrozen
1. Check cook temperature
2. Decrease cook time
3. Change oil
4. Keep product at 0°F or
below
Product not done
1. Low oil temperature
2. Food basket overloaded
3. Cook time too short
1. Check cook temperature
2. Decrease load
3. Increase cook time
No flavor
1. Overcooked
2. Old product
1. Check cook time
2. Discard
White spots
1. Product stuck together
2. Food basket overloaded
1. Float basket while load-
ing
2. Decrease load size
Dark spots
1. Dirty oil
1. Filter or replace